![](/html/4a/4ac3/4ac3f753f3556095094fea0fbf500493594173fe9644cf735e9efea0b36dcd29/bg1.png)
VIDEO DOOR ENTRY SYSTEM INSTRUCTIONS
![](/html/4a/4ac3/4ac3f753f3556095094fea0fbf500493594173fe9644cf735e9efea0b36dcd29/bg2.png)
Table of contents
Enterview 5 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Door Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maximum Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Additional Keypad and Magnetic Lock Wiring . . . . . . . . . . . . . . . . . . . . . . . . . 7
Additional Keypad and Yale-release Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Keypad Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Trouble Shooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Additional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2
![](/html/4a/4ac3/4ac3f753f3556095094fea0fbf500493594173fe9644cf735e9efea0b36dcd29/bg3.png)
Enterview 5 Overview
4 Handsets maximum per-system
2 Audio-Only handsets maximum per-system
Each handset requires supplied PSU (1 PSU per handset required)
Keypad Camera requires suppIied PSU
Standard Camera requires EVBPS for door release facility
For a voltage-free contact: Keypad Camera requires a12VDC relay (not supplied)
AT5e cable speci fied for maximum distances
C
100 Meters maximum distance between outdoor station and furthest handset
10 Meters maximum distance between handset and supplied PSU - Note: 2 pairs of
CAT5e must be used to achieve this distance
1 3 2 4
EVH5C-HF
EVH5AOEVHF10B / EVHF10W
EVH5
Keypad Camera
1
2
3
2
3
Standard Camera
1
2
1 3 2 4
1 – Opens Camera Channel
2 – Door Release
3 – Call Transfer
4 – Opens 2-way Audio
1
2
3
3
1 – Camera
2 – Speaker
3 – Call Button
3
![](/html/4a/4ac3/4ac3f753f3556095094fea0fbf500493594173fe9644cf735e9efea0b36dcd29/bg4.png)
Wiring Configuration
AC240 AC240
Standard Camera
Handset PSUs
provided
LOCK
Keypad Camera
See additional wiring instructions for Keypad
LOCK
4
AC240
Keypad PSU provided
AC240 AC240
Handset PSUs
provided