Surface mount the sunshield of the door station and connect
the system cabling. Mount the camera to the sunshield by
fixing with the supplied hex screw.
90
1.2 m 1.5 m
Avoid areas of high sunlight
and noise levels.
The camera needs to point in the
direction of where a visitor will
stand during operation.
Site the door station a recommended 1.5 meters
from the ground, or to suit application.
APDSSW manual.qxp_Layout 1 29/01/2016 13:00 Page 4
5
BUS
BUS
BUS
240vAC
INPUT
POWER SUPPLY
Power supply to be with-in 100 meters
of monitor
No cable
or connection
polarity
Ensure the Address ID switches are both set to OFF
Address ID
01
Total cable run
should not exceed
150 meters between
door station and monitor
MASTER
Refer to instructions supplied with monitor for MASTER/ SLAVE configuration
System Connections Example 1
APDSSW manual.qxp_Layout 1 29/01/2016 13:00 Page 5
The system power supply can support up to 5 devices
1
2
3
Only one monitor is set as the MASTER:
All other monitors set as SLAVE:
Power supply to be
with-in 100 meters
of monitor
No cable
or connection
polarity
Total cable run
should not exceed
150 meters between
door station and monitor
BUS
BUS
BUS
BUS
Address ID
01
Address ID
02
BUS
BUS
POWER SUPPLY
240vAC
INPUT
The dipswitches are accessable
on the rear of the door station
Address ID 02Address ID
03
Address ID
01
Address ID
04
MASTER
SLAVE
SLAVE
When using multiple door stations ensure that each unit has a seperate Address ID
Refer to instructions supplied when using different version of monitor for MASTER/ SLAVE configuration
APDSSW manual.qxp_Layout 1 29/01/2016 13:01 Page 6
7
At the rear of the door station ensure that the jumper links cover pins 1 and 2, on both J3 and J2 positions
1
2
3
J1
J2
J3
NC
4 3
+
+
+
_
_
_
Electro-magnetic lock
Electronic lock
BUS
System Wiring
LOCK1
VCC
J1
Image of jumper link
Lock -release time
N.C for Electro-magnetic lock
N.O for Electronic lock
Lock Connections Example 1
APDSSW manual.qxp_Layout 1 29/01/2016 13:01 Page 7
The jumpers on the rear of the door station offer different types of release modes for alternative applications dependent on the jumper link settings. LOCK1 options;
N.O
N.C
N.O
Volt-f ree
Volt-f ree
12vDC300mA
MAX
Jumper 1 gives the option to set the release time;
5
sec.
3
sec.
The door station has a secondry switch. LOCK2 options;
Please refer to the operation guide for release instructions
1
2
3
J1J3J2
1
2
3
J1J3J2
1
2
3
J1J3J2
N.O
N.C
N.O
Volt-f ree
Volt-f ree
12vDC300mA
MAX
1
2
3
J1J3J2
1
2
3
J1J3J2
1
2
3
J1J3J2
Image of jumper link
Image of jumper link
APDSSW manual.qxp_Layout 1 29/01/2016 13:01 Page 8
9
Press the ‘Talk’ button
to end call
Press the ‘Lock’ button
to release lock and press
‘Talk’ to end call
Press the ‘Gate’ button
to release lock 2 and press
‘Talk’ to end call
The visitor
presses the
call button
A chime will sound The visitor’s image will
appear on the monitor
Press the ‘Talk’ button
and begin conversation
Then choose between
the 3 options below
ABCDE
123
Call Button
User Guide
APDSSW manual.qxp_Layout 1 29/01/2016 13:01 Page 9
APDSSW manual.qxp_Layout 1 29/01/2016 13:01 Page 10
11
APDSSW manual.qxp_Layout 1 29/01/2016 13:01 Page 11
APDSSW manual.qxp_Layout 1 29/01/2016 13:01 Page 12
Loading...