Please read this manual carefully for installation and
keep it well, pls contact your local dealer for any
question
CONTENT
GENERAL -----------------------------------------------
INSTALLATION INSTRUCTION -------------------
PIPE CONNECTION ---------------------------------
ELECTRICAL CONNECTIONS -------------------
CONTROL ----------------------------------------------
EXPLODED VIEW -----------------------------------
TECHNICAL DATA -----------------------------------
CONTROL ----------------------------------------------
ATTACH.1 -----------------------------------------------
ATTACH.2 -----------------------------------------------
ATTACH.3 -----------------------------------------------
ATTACH.4 -----------------------------------------------
1
3
4
7
14
21
23
24
25
26
27
28
Main circulation pump
Water tank circulation pump
OPERATION PRINCIPLE
ES NORD
ES NORD
Schematic illustration of heat pump and indoor module
connected to the house
1
2
5
BA-H050, BA-H075, BA-H140, BA-H220, BA-H280
PRODUCTS DESCRIPTION
ES NORD heat pump range. They are
ES NORD
65
ES NORD
If the water temperature is not acchieved after heat pump heating
for 60 minutes, electric heater is turned on to assist the heating till
the targeted temperature is reached
until
and valves).
2
Venting valve
one way valve
Water output
Water Input
Water Input
Water Input
Hot water output
3
4
2
8
1
5
Safety valve
Safety valve
Safety valve
Buffer tank
Input/Qutput connection : DN25
4
circulaton
Water tank
circulation pump
ion
ion
5
Venting
Open the pump electric cover
by screwing, fix the terminals
according to the schematic
symbols.
venting valve
6
The signal wire of outdoor unit should be
fixed onwith the 9 poles terminal block.
The signal wire should lead to indoor unit
5 cores internal power supply cable leads
to indoor unit5 poles terminal block
9 cores internal digital wire cable leads
to indoor unit9 poles terminal block
Wire controller pannel
It connect outdoor unit by wire
and quick-conncetfitting.The
wire controller leads to room.
Room temperature sensor
It connect outdoor unit by wire and
quick-connect fitting.It should lead
to room ,and should be fixedby sensor
holder .The room temperature sensor
device should fixed on wall in the room.
The signal wire lead to outdoor
unit 9 poles terminal block
5 cores internal power supply cable leads
to outdoor 5 poles terminal block
5 cores power supply cable leads to
air break switch Power supply rated
3 Phase AC 400V 50Hz
Indoor unit
Outdoor unit
(9*cores rated 1.5mm2 digital wire)