ESD 94390, 94392 Operation, Installation, And Maintenance Manual

TECHNICAL BULLETIN TB-5536
Ground Gard 4.5 Operation, Installation, and Maintenance
Continuous Monitors eliminate the need for users to test wrist straps and log the results; by their function,
these monitors satisfy the ISO 9000 and ANSI/ESD S20.20 Paragraph 6.2.2.2 test logging requirements. Per ESD-S1.1 paragraph 6.1.3 Frequency of Functional
Testing “Daily (Wrist Strap) testing may be omitted if constant monitoring is used.”
“Because wrist straps have a nite life, it is important to develop a test frequency that will guarantee integrity of
the system. Typical test programs recommend that wrist straps that are used daily should be tested daily. However, if the products that are being produced are of such value that knowledge of a continuous, reliable
94390
Figure 1. SPI Ground Gard 4.5
94392
ground is needed, and then continuous monitoring
should be considered or even required.” (ESD Handbook TR 20.20 section 5.3.2.4.4)
Made in the
United States of America
Description
This unit provides continuous monitoring of:
• Two users wearing a wrist strap
• Ground
For a SPI Continuous Monitor that also monitors the ESD worksurface see SPI model Ground Gard 5.
Leading companies use continuous monitors as a cost
e󰀨ective component in satisfying the paragraph 6.1.3 Complicance Verication Plan requirements of ANSI/ ESD S20.20. The SPI Ground Gard 4.5 Continuous
Monitor provides continuous monitoring of two operators and also functions to ensure connection to ground. If the monitor, using capacitance technology, detects improper grounding of the operator, the monitor will issue an audible alarm alongwith an illuminated red LED to notify the user of a problem.
Many customers are eliminating periodic testing and are utilizing continuous monitoring to better ensure that their products were manufactured in an ESD controlled environment. Continuous monitoring is superior to
periodic testing. “While e󰀨ective at the time of testing,
wrist strap checker use is periodic. The failure of a wrist strap between checks may expose products to damage from electrostatic charge. If the wrist strap system is
checked at the beginning of a shift and subsequently
fails, then an entire shift’s work could be suspect.” (ESD
TR 12-1 Section 1.0 Survey of Constant Monitors for
Wrist Straps)
The Ground Gard 4.5 is available in two models. The item numbers are listed below:
Item Description
94392 Ground Gard 4.5 with Buzzer, 120V
94390 Ground Gard 4.5 with Buzzer, Building Ground, 120V
*Contact manufacturer for quote on 220V models
The Ground Gard 4.5 will alarm if preset values are exceeded for capacitance, high resistance and ground loss conditions. The grounding system is redundant and will still provide limited grounding even if the utility ground is lost and the system is in an alarm state.
Capacitance Type Continuous Monitors
“This type of monitor is used with a single wire (single conductor) wrist strap. Monitors in this category operate
by “sensing” body capacitance. For capacitance
monitors, an AC voltage is applied to the wrist strap through the single conductor ground cord. Due to capacitive coupling of the person to ground based on the surroundings, the monitor will indicate either good or bad depending on the manual adjustment or preset tolerance. SInce a capacitor or capacitive network responds like a resistor to an AC current, the single conductor wrist strap monitor only provides an estimate of the wrist strap wearer’s apparent resistance.” (ESD
Handbook TR 20.20 section 5.3.9.2 Types of Continuous
Monitors)
ESD Systems.com • 432 Northboro Road Central • Marlboro, MA 01752 • (508) 485-7390 • Website: ESDSystems.com
ESD Systems.com • 432 Northboro Road Central • Marlboro, MA 01752 • (508) 485-7390 • Fax (508) 480-0257 • Website: ESDSystems.com
TB-5536 August 2018 Page 1 of 3
© 2018 DESCO INDUSTRIES INC
Employee Owned
Packaging
1 Ground Gard 4.5 Monitor
2 94340 Operator Remotes
1 Operator Remote Cables, 10 ft. 1 Monitor Ground Cord, 12 ft. (94390 only) 1 Hook and Loop Fastener Strip 1 12VDC Power Adapter, North America 1 Certicate of Calibration
Remote Module Description
Inside both remote modules are infrared sensors that react to the insertion of a wrist strap wire with a banana plug. When the banana plug is inserted, the base unit is activated for that remote module. The Monitor Head LED for the left or right wrist strap will light showing the condition of that strap. If correct, the LED should be
GREEN.
Installation
1. GROUND GARD 4.5 Monitor Head:
The Ground Gard 4.5 Monitor Head is designed to maximize valuable work area and should be mounted at eye level above the workstation, either on a post or shelf
support. A double-sided adhesive Velcro® attachment is
provided to hold the lightweight head in place.
2. GROUND CONNECTION:
The green wire extending from the monitor head (item
94390) must be attached to equipment ground. This wire
can be connected directly or looped through the conductive table top or mat to ground. There is no green wire on item 94392. For this item, the ground connection
is made through the third prong of the 3-wire Power
Adapter.
Caution: The total amount of resistance through all
monitored parts should not exceed 10.0 megohms
total.
3. REMOTE OPERATOR MODULES:
The remote operator modules can be mounted at the front of the work surface, usually under the tabletop and
ush with the front edge. Two screws for each unit are
provided for mounting. Connect each remote to the
monitor unit using the telephone cable with RJ11
connectors.
4. POWER UP TEST
After installing the Monitor Head, remote units, and making the necessary connections without the wrist
straps connected, the unit should POWER UP with the wrist strap LED’s OFF and the audible alarm SILENT.
If you have no response to power or a red LED, check AC outlet for proper ground or refer to trouble shooting section.
PARK SNAP
The audible alarm is designed to alert both operator and
supervisor. The Park Snap feature provides a means
for an operator to disconnect when normally leaving the work area, without the audible alarm sounding, and it provides a means of wrist cord storage (visual red LED will illuminate). You may also disconnect coil cord by unplugging banana plug from the Remote Operator
Module. Both a 7mm and 4mm Park Snap is provided on
each module.
Should the wrist strap fail, be worn incorrectly or
removed by the operator, the red indicator will ash,
calling attention to a problem. Should the ground connection be lost, the red light and alarm will be activated The monitors are continuous and even a momentary break will cause alarms. The remote modules are set at the factory to allow for sensitivity of the “average” human body model.
Calibration Procedure Using 94335 Tester
With coiled wires connected to test unit and each remote, observe the following: both lights should illuminate green on the head module, with no buttons depressed on the
tester. Pressing buttons one or four should cause the left
or right wrist strap to go red simulating a high resistance condition on the wrist strap. This shows that the Remote Operator Module is properly calibrated.
If the above conditions are not met, complete the following adjustment:
With buttons one and four not depressed, the LED display on the head module should be in a green
condition. If not, nd the adjusting port on the remote.
Inside there is an adjusting trim pot. Turn the trim pot slightly until the head module LED turns green.
Step One: Turn the pot until the green LED triggers red, then ease back until LED triggers green.
Step Two: Press the corresponding button on the test
unit and the LED will go red on the head module. This shows the Ground Gard remote is in a proper calibration.
Note: If the unit does not go red, go back to step one and repeat procedure.
Installation Adjustments
Should your system alarm without obvious cause, rst
troubleshoot and verify all connections. If all the connections are correct, the base unit should be
adjusted to compensate for a di󰀨erent HBM (human body model). We preset the units at the factory at 100pF
and your operator might be out of the tolerance range caused either by body chemistry, bulk capacitance or
impedance di󰀨erences.
Follow these steps to adjust and personalize the base
unit:
ESD Systems.com • 432 Northboro Road Central • Marlboro, MA 01752 • (508) 485-7390 • Website: ESDSystems.com
ESD Systems.com • 432 Northboro Road Central • Marlboro, MA 01752 • (508) 485-7390 • Fax (508) 480-0257 • Website: ESDSystems.com
TB-5536 Page 2 of 3
© 2018 DESCO INDUSTRIES INC
Employee Owned
Loading...