Escea FS730 Installation Manual

Page 1
630346_0 FS730 Builders and Architects Sheet
Product Dimensions
All outside dimensions taken from the appliance are with the standos attached.
FS730
Information Sheet for Builders and Architects
Appliance Information
For further information or specications, visit the technical section of our website www.escea.com to view the latest product Installation Manual.
Specications
Heat Output 5-5.6 kW Star Rating 3-4 stars Gas Input/Consumption 22-25 MJ/hr Gas Connection lower right, 1/2” BSP female thread Gas Type Natural Gas / ULPG (NZ) / Propane (Aus) Weight 45 kg Room fan Yes Flue Type Simpson Duravent Direct Vent (False Chimney) Flexi Flue (Masonry) Flue Size 6” mm Outer, 4” mm Inner (Direct Vent) 4” and 3” Flexi Flue (Masonry) Power Requirement 3 pin earthed 230V power outlet +isolating switch to be within 1.0m of rear right hand corner of the appliance. Smart Heat App Yes
Flue Installation
505mm
735mm*
381mm
124mm
753mm
368mm* 368mm*
*Not including Lid
The freestanding unit and flue system should be installed prior to the AF­Series fireplace being installed.
□ Place the freestanding unit in the correct location, complying with the clearances specified in the previous section.
□ Remove 2 screws on each side of the fascia just below the top panel and pull towards you to remove the fascia.
□ Each corner of the FS730 has securing holes to fix the FS730 to the floor.
□ Refer to section C of this instal­lation manual for minimum and max­imum flue lengths, restrictor settings for your installation, and all other flue information.
□ Run the black Ø230mm flue liner lengths from the top of the freestanding unit until it penetrates the Ø265mm ceiling hole.
□ Use the supplied Ceiling plate for tidying the internal termination point of the Ø230mm flue liner.
□ Run the 2x flexible flues down through the Ø230mm flue liner and attach it to the Flue Spigot Plate as per section C of this manual
□ Open the flue liner rodent guard and close around the flexi flue. Rivet, screw or cable tie the open end to prevent it from opening. Bend the two perpendicular tabs down and screw into the flue liner using a short self tapping screw. Note: Take care when installing the rodent guard to not cause damage to the flexi flue.
□ Install flue termination as per section C of this manual
Note: Ensure a power supply is within 1m of the rear of the appliance.
Ceiling Ring
225mm Flue liner
2x Flexible flue inner
Coaxial to Colinear conversion box
Duravent 4x6” Rigid Direct-vent flue
Rigid flue
Flexible flue clamped to Flue SpigotPlate
AF700 Fireplace
FS730 Freestanding Unit
Flue Liner Rodent Guard
Ø265 mm Ceiling hole
Page 2
630346_0 FS730 Builders and Architects Sheet
Vertically terminating flue diagram
Flue Information
IMPORTANT : Refer to the installation manual for mandatory clearances from the terminal.
Clearances
Flueing Clearances
25mm
=
Minimum distance to combustibles
50mm 50mm
0mm*
*Note: Underside of converter box can be xed straight onto wooden joists. **Note: Flexi-Flue must not be run at an angle greater than 45 degrees from
vertical; excluding all appliance built into a freestander kit.
50mm
50mm
>45°**
50mm
Ø75mm Intake
Ø100mm Exhaust
50mm
25mm
25mm
600mm
300mm to
78 mm
Converter Box Dimensions
Hearth and Clearances
A Hearth is not required, however it may be used for decorative purposes or for protection of sensitive flooring. The hearth should not obscure the front face of the fire.
Do not place items or furnishings ontop of the freestanding fireplace, and ensure soft furnishings do not come in contact with the freestanding fireplace.
175mm
315mm
50mm
50mm 50mm