ESAB Transcool 351 Torch Water Cooling Unit Instruction manual / Spare parts list (Replacement parts)

Transcool 351
Torch Water Cooling Unit
Introduction
This high efficiency torch water cooling unit has been designed to be used with the Transtig 203i, 253i or 353i TIG welding equipment, although it can also be used as a free standing unit with other similar equipment. It operates from either a 115V or 230V 1 phase 50 Hz electricity supply. The metal enclosure contains a moulded reservoir tank, motor/pump assembly, radiator, cooling fan and water flow detection circuit. In the event of failure of the water flow an alarm will sound and a warning light will illuminate on the control panel.
Specification:
Electricity Supply: 115V or 230v ±10%
1 phase 50 Hz
Capacity (excl torch) 5 litres Working Temperature 47ºC (300A/22V) Water Flow Rate: 2 lpm (3.8m Torch) Dimensions (LxWxH): 610mmx290mmx250mm Weight: 17.5 kg
Coolant
Distilled water is normally recommended however, where there is a possibility of the coolant freezing, distilled water with a minimum of 25% glycol antifreeze added should be used.
Installation
1. Attach the torch water inlet hose (blue) to the quick connector marked with the water out symbol.
2. Attach the torch water return hose (red) to the quick connector market with the water in symbol.
3. Fill the tank with coolant, see above.
4. Connect the mains lead to a suitable 115V or 230V ac supply.(A 230v supply is provided by the Transtig 203i, 253i and 253i). Check the supply is fused at 6.3A
5. Switch on and allow the coolant to circulate. Note that the audible alarm may sound while air is pumped out of the system.
6. Top up the coolant, to level with the top of the sight window.
WARNING!
1. Do not operate the unit without coolant. Check coolant level regularly.
2. Do not operate the unit without the torch connected.
Maintenance
WARNING!
Always isolate the unit from the electricity supply before removing the cover.
1. Check the coolant level regularly. If necessary top up using the same coolant as already used.
2. At least once a year drain down the coolant, flush out the system and refill with fresh coolant.
3. To keep the unit at peak performance, the cover should be removed at regular intervals (at least once per year) and any accumulated dust blown out.
4. If the unit is taken out of service for long periods, the system should be drained, and then refilled with fresh coolant to keep the pump ‘wet’.
Service
Inspection and repair of this equipment should only be carried out by a suitably qualified person. Defective parts should be only be replaced by genuine Murex parts.
Warranty
The Transcool 351 is guaranteed for 24 months against defects in either materials or workmanship. This warranty excludes failure as a direct result of incorrect use or lack of maintenance. Contact your local approved Murex service centre or distributor.
Transcool 351 Parts List
Circuit Diagram
Item Description Part Number
1 Handle 0700066184 2 Cover Lid 0706200280 3 Radiator 0700063429 4 Resrvoir Tank 0700066302 5 Fan Blade 0700066303 6 Pump/Motor Assembly 0700064629 7 Front Plate 0700066937 8 Female Coupling Red 0700063147
9 Fuse 6.3A Slow Blow 0700064207 10 Fuse Holder 0700064180 11 Chassis 0706200270 12 On/Off Switch 0700064056 13 Female Coupling Blue 0700063145
Pressure Switch & Coupling 0700063146
14
Aux. Transformer 0700064637
15
Indicator PCB 0700061952
16 17 Cable Grommet 0700066061 18 Power Cable 0700066490
Wiring Diagram
Murex Welding Products Limited
Hanover House, Queensgate, Britannia Road, Waltham Cross, Herts EN8 7TF. England
Telephone No. Email: info@murexwelding.co.uk
01992 710000 -
Fax No.
01992 717699
Loading...