ESAB Power Source Faults When Connecting DuraDrive Wire Feeder Troubleshooting instruction

www.esabna.com

DATE: January 22, 2004 BULLETIN NO: M-04-001

TITLE/ PRODUCT NAME: Power Source Faults When Connecting DuraDrive Wire Feeder
_ (Action is Required) (Potential Problem)
_ (Action is Optional) (Enhanced Product)
_ (Unrestricted) (Restricted Distribution)
PRODUCT SERIES/ MODEL: ESAB 353cv, 453cv and 653cvcc Power Sources
Control Board PN 38129 & 38130
SERIAL NO:
All Serial Numbers
SUMMARY:
This Instruction will eliminate a nuisance power source fault light when connecting a DuraDrive 4-30 or 4-48 wire feeder. The fault condition is caused by a transient voltage spike in the 12 volt control circuit when power is applied to the DuraDrive feeder. An additional 22 microfarad capacitor is added to increase the time constant of the power up reset circuit which eliminates the false triggering of the fault light.
_ DIRECTIVE _X_ ALERT
X_ INFORMATION _ _ PRODUCT IMPROVEMENT
X_ General Distribution _ _ Business Confidential
OPERATIONAL IMPACT:
None
ACTION:
+
+
1. Remove the Main Control PCB from the power source.
2. Solder the positive (+) lead of the 22 microfarad electrolytic capacitor to the banded (+) end of diode D46. See photo below.
3. Solder the negative (-) lead to the end of R159 that is the emitter lead of transistor Q30 & Q31.
4. Re-install control PCB into power source.
22 microfarad 50 vdc
capacitor PN -951013
-
-
CONTACT:
ESAB Welding & Cutting Products Product & Service Information Group 843-664-4416 Phone 843-664-5539 FAX