ESAB Power Line Filter/Conditioner Troubleshooting instruction

INSTRUCTIONS for
POWER LINE FILTER/CONDITIONER
Installing
P/N 35910 - 600 vac, 3-phase, 16 amp/phase P/N 35911 - 600 vac, 3-phase, 25 amp/phase
POWER LINE FILTER
600VAC, 3 PHASE 16 AMP/PHASE
P/N 35910
F-15-297
March, 1996
OUTPUT
TO
INVERTER
Power Line Filter/Conditioner is recommended for use with inverter type power sources where 460 or 575 volt input power surges and spikes are common. It will also reduce input current draw by at least 25% as well as improve power factor and efficency.
The 10" X 8" X 7" Filter/Conditioner is wall mountable. It should be located no more than 2 feet from the power source. The Filter/Conditioner is equipped with a 12­foot long, 4-conductor, #10A WG input power cable for connecting to your 460 or 575 vac power.
F-15-297
P/N 35910 Filter/Conditioner can be used with any 460 or 575 vac, 3-phase power source having an input cur­rent draw up to 16 amps/phase such as PCM-750i (460 575 vac) and PCM-1000i (575 vac). P/N 3591 1 is de­signed for power sources with higher input current draw up to 25 amps/phase such as PCM-1000i (460 vac), SVI 300i, and SVI 450i.
INPUT
POWER
Before installing this accessory, make sure all in­put power is disconnected and/or lock out proce­dures are in place.
To install Filter/Conditioner, refer to inst allation instruc­tions and Figures 1 and 2 on the back of this form.
Be sure this information reaches the operator. You can get extra copies through your supplier.
T o inst all Filter/Conditioner, proceed as follows:
1. Cut off input power cable to the power source to 2 feet maximum. Strip insulation off the end of each wire to expose 1/2" to 5/8" of bare wire.
2. Open the filter/conditioner box cover. Insert the power source's input power cable through the strain relief at the output end of the box.
2 ft.
Max
3. Connect the white, red and black wires to terminals A2, B2 and C2 respectively in the box and connect green ground wire to the ground terminal. Make sure all connections are tight. Tighten the strain relief to secure the power cable.
NOTE: If connecting for single phase, use only the black
and white wires.
4. Connect the 12-ft. long input cable of the filter/condi­tioner box to your 460 or 575 vac power supply . Y our power source is now ready for return to welding or cutting operation.
Any Length*
To Input Power Line
PCM-750i or PCM-1000i
35910 or 35911
* 35910 & 35911 are equipped W/12 ft. 4-cond cable.
Fig. 1 - Interconnection Diagram
CABLE, 4-COND/#10AWG
- 36275
BOX, 16A - 32222 25A - 32223
REACTOR, 16A - 52164
L1
A2
L
O
B2
A D
C2
R3
C3
C2 C1
SCHEMATIC
A1
B1
C1
R2 R1
L
I N E
(3) RESISTOR 330K 1W 10% (R1,2,3) - 17130433
(2) STRAIN RELIEF
3/4 NPT
- 13734727
25A - 52165
LABLE, DANGER
- 954008
(3) CAPACITOR
2.2uf 300VAC (C1,2,3) - 952163
DECAL, GROUND
- 2091558
BRACKET, MOUNTING CAPACITOR
- 36282
Fig. 2 - Schematic Diagram/Replacement Parts - Filter/Conditioner Assembly, P/N 35910 and 35911.
F-15-297 3/96 1M Printed in U.S.A.