ESAB Mounting Gas Flowmeter Kit Troubleshooting instruction

Instructions for
F-15-484
August, 1998
Mounting
GAS FLOWMETER KIT
P/N 36658 for Argon Shielding Gas
P/N 37365 for CO2 Shielding Gas
to MobileMaster 2cvcc or 2cv
Each kit includes the following components:
L-33 Flowmeter Assembly, P/N 21988 (Ar) or P/N 21990 (CO2) Elbow, Inert Gas, P/N 952698 Adapter, B I.G. x 1/4 NPTM, P/N 74S76 Flowmeter Cage, P/N 37394BK
To install kit, proceed as follows (see Fig. 1):
To prevent accidental electric shock, be sure contol cable is disconnected from power source or inter­face box before working inside the wire feeder.
1. Remove the four (4) mounting screws on the rear panel of the MobileMaster. Then assemble the flowmeter cage as shown in Fig. 1 and secure with the same 4 mounting screws. The welding cable connection (not illustrated) on the MobileMaster should come out the bottom window of the cage.
2. Remove factory assembled inlet connection from flowmeter, if any, and replace with the supplied 74S76 Adapter. Tighten the adapter firmly with a wrench.
3. Assemble the supplied P/N 952698 Elbow to the outlet port of the flowmeter. With the flowmeter valve facing towards you, position the elbow to face directly to the left. Tighten this connection firmly with a wrench.
4. With the flowmeter valve facing towards you, It may be necessary to rotate the calibrated tube in the flowmeter so that the calibrated readings are fac­ing directly to the right and visible when assembled to the MobileMaster. To do this: refer to F-15-333 packed with the flowmeter assembly; unscrew the top retainer (not the bursting disk cap); rotate the calibrated tube to the desired position; reassemble retainer.
5. Insert the flowmeter assembly under the cage, and then connect the elbow of the flowmeter assembly to the shielding gas connection on the rear panel of the MobileMaster wire feeder. Make sure the flowmeter is positioned vertically, and then tighten the connection nut firmly.
6. Connect the shielding gas supply hose to the inlet connection of flowmeter. Tighten the connection firmly using two wrenches.
7. For operating details on the L-33 flowmeter, refer to Instructions F-15-333 packed with the flowme­ter.
Be sure this information reaches the operator. You can get extra copies through your supplier.
Flowmeter
Cage
L-33 Flowmeter
Adapter -
74S76
Elbow ­952698
Fig. 1 - Flowmeter Kit Mounted to Rear Panel of MobileMaster
F-15-484 8/98