ESAB Flow measuring kit for plasma torch Instruction manual

INSTRUCTIONS for
PLASMA T ORCH
FLOW MEASURING KIT
P/N 19765
The kit includes 50-500 cfh Rotameter (19768), cone adaptor (19766), and 2-ft. hose assembly (19767).
F-14-391-C
September, 1996
For measuring flows up to 40 cfh, order P/N 19043. Measure one gas (plasma or cooling) at a time whenever
possible. When there is a single source for both plasma and cooling gas, measure the total flow .
Instructions for measuring torch gas flows using the hand held Rotameter .
WARNING
!
High Voltage can kill. Follow the steps below to as­sure safe flow measurements.
1. Shut off input power to the power supply at the main disconnect switch.
2. Unplug the torch switch cord from the unit.
3. Install a new nozzle and electrode in the torch.
4. Turn on the power at the main disconnect switch.
5. Place gas mode selector switch on unit in SET-UP position.
6. Place power switch on unit to ON position.
7. The Rotameter must be held in the upright vertical position to give a proper measurement. Measure the flow of a manual torch by installing the cone adaptor to the bottom of the Rotameter hand tight (do not over tighten), hold the torch in an inverted vertical position and place the cone adaptor firmly over the torch nozzle and heat shield.
For a mechanized torch, remove the torch from its mount and use the meter as described above or in­stall the cone adaptor on the female thread of the hose and the male thread of the hose to the Rotameter . This will allow use of the Rotameter with the torch installed on the machine.
8. Read the gas flow at the top of the Rotameter float and compare this to the flows listed for your torch on this document. If the flows are not as specified here, check to be sure the proper pressure has been set at the power source regulator, check for damaged or kinked supply hoses and check for leaks at all gas fittings. Make the necessary repairs or adjustments and recheck the flow.
9. After checking the flow, place power switch on unit to OFF.
10. Turn off power to unit at main disconnect switch.
1 1. Reconnect torch switch plug to unit.
WARNING
!
Do NOT use with torch switch ON. Use SET-UP switch for flow.
Be sure this information reaches the operator. You can get extra copies through your supplier.
PT -121 Torch Gas Flows:
NOZZLE P/N: 17184 171 19 999263 Plasma Gas:
Nitrogen @ 25 psig 20-50 cfh 40-90 cfh 50-100 cfh H-35 @ 65 psig 25-75 cfh 85-135 cfh 125-180 cfh
Cooling Gas:
N
or air @ psig 170-230 cfh 170-230 cfh 310-370 cfh
2, O2
CO2 @ 25 psig 130-190 cfh 130-190 cfh 240-300 cfh
PT-17A T orch Gas Flow (All Nozzles)
Total Air Flow @ 75 psig: 290 cfh minimum
PT-20 AM T orch Gas Flow (All Nozzles)
Total Air Flow @ 75 psig: 325 cfh minimum
PT-23/PT-27 Torch Gas Flow (All Nozzles)
Total Air Flow @ 75 psig: 240 cfh minimum
PT-25 Torch Gas Flows:
Air or N2 @ 70 psig Cooling Gas: 280-360 cfh Plasma Gas: 115-140 cfh Total Flow: 395-500 cfh
PT-31XL T orch Gas Flows:
NOZZLE P/N: 19667 18866 18820
Total Air Flow @ 40 psig: 140 cfh minimum 190 cfh minimum