GB
Valid for serial no. 620--xxx--xxxx0458 716 201 GB 071005
Feed 3004
Feed 4804
Aristot
Instruction manual

-- 2 --
TOCe
Rights reserved to alter specifications without notice.
1 DIRECTIVE 3........................................................
2SAFETY 3...........................................................
3 INTRODUCTION 5...................................................
3.1 Equipment 5................................................................
3.2 Control panel 5.............................................................
4 TECHNICAL DATA 6.................................................
5 INSTALLATION 7....................................................
5.1 Lifting instructions 7.........................................................
5.2 Terminating resistors 8.......................................................
5.3 Connection of multiple wire feed units 8........................................
6 OPERATION 9.......................................................
6.1 Connections and controls 10...................................................
6.2 Water connection 10..........................................................
6.3 Remote control unit 11........................................................
6.4 Wire feed pressure 1 1........................................................
6.5 Changing / loading wire Feed 3004 12..........................................
6.6 Changing / loading wire Feed 4804 12..........................................
6.7 Replacing the Feed 3004 feed rollers 12.........................................
6.8 Replacing the Feed 4804 feed rollers 13.........................................
7 MAINTENANCE 13....................................................
7.1 Inspection and cleaning 13....................................................
8 ORDERING OF SPARE PARTS 14......................................
DIAGRAM 16............................................................
ORDERING NUMBER 19.................................................
WEAR COMPONENTS 20.................................................
ACCESSORIES 24.......................................................

-- 3 --
bm29d1ea
1DIRECTIVE
DECLARATION OF CONFORMITY
ESAB AB, Welding Equipment, SE--695 81 Laxå, Sweden, declares that Wire feed unit Feed
3004/4804 from serial number 620 (2006 w.20) are constructed and tested in compliance with the
standard EN 60974--5 and EN 60974--10 in accordance with the requirements of directive
(2006/95/EC) and (2004/108/EEC).
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --------
Kent Eimbrodt
Global Director
Equipment and Automation
Laxå 2007--03--14
2SAFETY
Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who
works on or near the equipment observes all the relevant safety precautions. Safety precautions
must meet the requirements that apply to this type of welding equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace.
All work must be carried out by trained personnel well--acquainted with the operation of the welding
equipment. Incorrect operation of the equipment may lead to hazardous situations which can result
in injury to the operator and damage to the equipment.
1. Anyone who uses the welding equipment must be familiar with:
S its operation
S location of emergency stops
S its function
S relevant safety precautions
S welding
2. The operator must ensure that:
S no unauthorized person is stationed within the working area of the equipment when it is
started up.
S no--one is unprotected when the arc is struck
3. The workplace must:
S be suitable for the purpose
S be free from drafts
4. Personal safety equipment
S Always wear recommended personal safety equipment, such as safety glasses, flame--proof
clothing, safety gloves.
S Do not wear loose--fitting items, such as scarves, bracelets, rings, etc., which could become
trapped or cause burns.
5. General precautions
S Make sure the return cable is connected securely.
S Work on high voltage equipment may only be carried out by a qualified electrician.
S Appropriate fire extinquishing equipment must be clearly marked and close at hand.
S Lubrication and maintenance must not be carried out on the equipment during operation.
GB

-- 4 --
bm29d1ea
WARNING
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAUTIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE
BASED ON MANUFACTURERS’ HAZARD DATA.
ELECTRIC SHOCK -- Can kill
S Install and earth the welding unit in accordance with applicable standards.
S Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
S Insulate yourself from earth and the workpiece.
S Ensure your working stance is safe.
FUMES AND GASES -- Can be dangerous to health
S Keep your head out of the fumes.
S Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone
and the general area.
ARC RAYS -- Can injure eyes and burn skin.
S Protect your eyes and body. Use the correct welding screen and filter lens and wear protective
clothing.
S Protect bystanders with suitable screens or curtains.
FIRE HAZARD
S Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.
NOISE -- Excessive noise can damage hearing
S Protect your ears. Use earmuffs or other hearing protection.
S Warn bystanders of the risk.
MALFUNCTION -- Call for expert assistance in the event of malfunction.
PROTECT YOURSELF AND OTHERS!
ESAB can provide you with all necessary welding protection an d accessories.
WARNING!
Read and understand the instruction manual before installing
or operating.
This product is solely intended for arc welding.
Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and returned to an
environmentally compatible recycling facility. As the owner of the equipment, you should
get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human health!
GB

-- 5 --
bm29d1ea
3 INTRODUCTION
The Feed 3004 and Feed 4804 wire feed units are intended for use with Mig power
sources.
There are several variants available: see on page 19.
They are totally enclosed, containing four--wheel feeders and the necessary control
electronics.
They are suitable for use with wire on ESAB’s MarathonPact, or on standard
bobbins (standard Ø 300 mm, accessory Ø 440 mm).
The units can be positioned in a choice of ways: on the power source itself, hanging
above the working position, on a support arm or with a wheelset on the floor.
ESAB’s accessories for the product can be found on page 24.
3.1 Equipment
The unit Feed 3004 is supplied with:
S Instruction manual for the wire feed unit.
S Instruction manual for control panel.
S Stickers with recommended wear parts.
The unit Feed 4804 is supplied with:
S Distance washer (4 pieces).
S Hexagon key (4 mm)
S Instruction manual for the wire feed unit.
S Instruction manual for the control panel.
S Stickers with recommended wear parts.
3.2 Control panel
The units are supplied with one of the following control panels:
Empty panel for use with double wire feed units or
with use of control box U8.
MA4
With knobs for setting the voltage and wire feed
speed / current. Other settings by pushbuttons, with
corresponding symbols on the display panel.
GB

-- 6 --
bm29d1ea
MA6
With knobs for setting the voltage and wire feed
speed / current. Other settings by pushbuttons, with
text indication on the display panel.
U6
With knobs for setting the voltage and wire feed
speed / current. Other settings by pushbuttons, with
text indication on the display panel.
Detailed descriptions of the control panels can be found in separate Instruction
manuals.
4 TECHNICAL DATA
Feed 3004 Feed 4804
Power supply 42 V 50 -- 60 Hz 42 V 50 -- 60 Hz
Power requirement 336 V A 378 V A
Motor current 8A 9A
Wire feed speed 0.8 -- 25 m/min 0.8 -- 25 m/min
Welding gun connection EURO EURO
Max. diameter of wire bobbin 300 mm (*440 mm) 300 mm (*440 mm)
Wire dimension 0.6 -- 1.6 mm 0.6 -- 2.4 mm
Operating temperature -- 1 0 t o + 4 0 ˚C -- 1 0 t o + 4 0 ˚C
Weight
basic unit
with bobbin carrier
with enclosed bobbin carrier
13 kg
16 kg
17.5 kg
18 kg
21 kg
22.5 kg
Dimensions (l x w x h)
basic unit
with bobbin carrier
with enclosed bobbin carrier
380 x 265 x 340 mm
560 x 265 x 350 mm
690 x 285 x 420 mm
380 x 265 x 340 mm
560 x 265 x 350 mm
690 x 285 x 420 mm
Shielding gas
max pressure
All types intended for
MIG/MAG welding
0.5 MPa (5 bar)
All types intended for
MIG/MAG welding
0.5 MPa (5 bar)
Coolant
max pressure
50% water / 50% mono--ethylen
glycol
0.5 MPa (5 bar)
50% water / 50% mono--ethylen
glycol
0.5 MPa (5 bar)
Permissible load at
60% duty cycle
500 A 500 A
Enclosure class
basic unit
with bobbin carrier
with enclosed bobbin carrier
IP23
IP2X
IP23
IP23
IP2X
IP23
* Accessory, see page 24.
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a certain load without overloading.
GB

-- 7 --
bm29d1ea
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Equipment marked IP2X is designed for indoor use.
5 INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
WARNING!
When welding in an environment with increased electrical danger, only power sources intended
for this environment may be used. These power sources are marked with the symbol .
5.1 Lifting instructions
Ordering number for the lifting eye can be found on page 24.
Note! If another mounting device is used, this should be insulated from the wire feed
unit.
GB

-- 8 --
bm29d1ea
5.2 Terminating resistors
In order to avoid communication interference, the
ends of the CAN bus must be terminated by resistive
loads.
One end of the CAN bus is at the wire feed unit control panel,
which incorporates a terminating resistor. The other end is in
the power source and it must be fitted with a terminating resistor,
as shown in the diagram to the right.
5.3 Connection of multiple wire feed units
When connecting multiple wire feed units (maximum 4), use wire feed units without
control panel and with control box U8.
Two feed units are to be connected according to the picture.
When connecting more than two feed units, an authorised ESAB service technican
must perform the installation.
GB

-- 9 --
bm29d1ea
6 OPERATION
General safety regulations for the handling of the equipment can be found on
page 3. Read through before you start using the equipment!
WARNING!
Assure that the side panels are closed during operation.
To prevent the reel from sliding off the hub: Lock the reel in place by
turning the red knob as shown on the warning label attached next to
the hub.
WARNING!
WARNING!
Rotating parts can cause injury, take great care.
WARNING!
There is a risk of tipping if the wire feed unit is fitted with a counterbalance arm. Secure the
equipment, especially if used on an uneven or sloping surface.
When moving the equipment use intended handle. NOTE! Never pull on the gun.
GB