ESAB FC-5C Foot Operated Remote Current and Contactor Control Instruction manual

INSTRUCTIONS for
Interconnection of these functions to the main power source is provided by a single mating 25-ft. cable/plug assembly provided.
F-14-496-A
FC-5 FOOT OPERATED
REMOTE CURRENT AND CONTACTOR CONTROL
Make sure all primary power to Power Source is dis­connected before installation of these plugs.
By depressing the foot pedal, the weld-start sequence circuit will energize, and the welding current will increase or decrease semi--linearly within the range preset on the power source “Current” control potentiometer.
To use the remote control, proceed as follows:
1. Plug the FC-5 control cable into current/contactor control receptacle on the power source.
2. Set the Remote/Panel toggle switch to the Remote position.
3. Set the Current Control on the power source panel to the maximum current range to be used.
4. Depress foot pedal as desired to weld.