INSTRUCTIONS for
F-15-126-A
February , 2002
FC-5B EHD FOOT OPERATED
REMOTE CURRENT AND CONTACTOR CONTROL
This remote control is designed for use with any power source
that employs a single (common) current and contactor control
14-pin Amphenol receptacle. It contains a potentiometer which
controls the current output when the Panel/Remote Switch
(PRS) on the power source is placed in the “Remote” position.
This remote control also consists of a switch when the PRS is
placed in the “Remote” position. Both the potentiometer and
switch are operated when the FC-5B EHD pedal is depressed.
See the schematic diagram in your respective power source
instruction literature.
Interconnection of these functions to the main power source is
provided by a single mating 30-ft. cable/plug assembly provided.
Make sure all primary power to power source is
disconnected before installing this control.
Pedal - 676152
Spring - 672749
Pin - 672750
By depressing the foot pedal, the weld-start sequence circuit
will energize, and the welding current will increase or decrease
semi-linearly within the range preset on the power source “Current” control potentiometer.
To use the remote control, proceed as follows:
Plug the FC-5B EHD control cable into current/contactor
1.
control receptacle on the power source.
Set the Remote/Panel toggle switch to the Remote posi-
2.
tion.
Set the Current Control on the power source panel to the
3.
maximum current range to be used.
Depress the foot pedal as desired to weld.
4.
Roll Pin, .094 X .501
Rack - 676147
Connector - 951019
Cover - 676151
Switch - 674592
To Nor Closed Terminal
To Com. Terminal
Ground
Roll Pin, .094 X .438
WHT
To Connector
GRN
Control
BLK
RED
BOTTOM VIEW
F-15-126-A 2/02 Printed in U.S.A.
SIDE VIEW
(4) Foot - 182W12
Cable Assy., 30 Ft. - 951520
Gear Hub - 673305
Potentiometer - 950715
FC-5B EHD Foot Switch Assembly - P/N 33841
FACE VIEW
G
H
F
E
M
DA
C
BLACK
A
WHITE
B
RED
D
ORANGE
E
BLUE
F
G
GREEN
H
I
N
J
K
L
B