ESAB FC-4 Potentiometer Assembly Installation manual

Page 1
INSTRUCTIONS for Installing
February , 1996
FC-4 POTENTIOMETER ASSEMBLY, P/N 18425
The enclosed assembly is a direct replacement for the potentiometer used in the FC-4 Foot Control P/N 679662; and it also replaces the potentiometer P/N 673303 used in earlier FC-4 Foot Controls P/N 676154. To install this replace­ment assembly, use the following sketch and pay particular attention to the placement location of the two brass washers marked with symbol (K).
the shoulder screw after installing shoulder screw.
Assembly Ref. Parts: 2-Brass WashersK
F-14-267-A
K Make sure that the two brass washers are located side-by-side between the angle support and the existing linear gear.
Apply Loctite to threaded hole
Current Control Plug
Copper Screw
Center Screw
Brass Screw
X Y Z
WHT
GRN
BLK
MAX
Shoulder Screw
Insulator Angle
Plastic Gear Hub.
Potentiometer Stem
Existing FC-4 Foot Switch Cover
Existing Linear Gear Attached To FC-4 Foot Pedal
Current Control Pot.
MAX
F-14-267-A
F-14-267-A 2/96 1M Printed in U.S.A.