ESAB ESP-200 Troubleshooting instruction Pilot Arc Capacitor Polarity

www.esabna.com
DATE: February 12, 2004 BULLETIN NO: P_04_003
TITLE/ PRODUCT NAME: ESP-200 Pilot Arc Capacitor Polarity
RATING:
PRODUCT SERIES/ MODEL:
This service bulletin applies to ALL ESP-200 Consoles (36324 & 36974).
SERIAL NO:
All serial Numbers
SUMMARY:
Reverse polarity applied to C3 may cause premature failure of C3. Even if C3 were to fail, the console would continue to operate in a normal manner with the possibility that the pilot arc current may be higher than expected which may cause reduced consumable life
OPERATIONAL IMPACT:
Possibly improved consumable life.
ACTION:
Perform this service bulletin on any consoles that come into the repair station for repair. This change will prevent C3 from being subjected to voltages of the wrong polarity during the Pilot Arc phase of the cutting process.
EXPLANATION:
Capacitor C3 (4200 uF / 350 VDC), has been found to be wired with the polarity reversed.
_ DIRECTIVE _X_ ALERT
X_ INFORMATION _ _ PRODUCT IMPROVEMENT
X_ General Distribution _ _ Business Confidential
Replace C3 with a new (8)950627 (same part) by mounting the new part in the console with the vapor release (red dot) in the up position. Connect the Blue wire to the negative terminal of C3 (no marking) along with one end of R6 (10K 12W). Connect the Yellow wire to the positive (+) terminal of C3 along with the other lead from R6.
CONTACT:
ESAB Welding & Cutting Products Product & Service Information Group 843-664-4416 Phone 843-664-5539 FAX