Rights reserved to alter specifications without notice.
TOCe
-- 2 --
GB
1DIRECTIVE
ESAB AB, Welding Equipment, SE--695 81 Laxå, Sweden, gives its unreserved guarantee that weld-
DECLARATION OF CONFORMITY
ing power source Arc 150i from serial number 620 complies with standard IEC/EN 60974--1, in accordance with the requirements of directive (73/23/EEC) and addendum (93/68/EEC) and with standard IEC/EN 60974--10 in accordance with the requirements of directive (89/336/EEC) and addendum (93/68/EEC).
Kent Eimbrodt
Global Director Equipment and Automation
ESAB AB
695 81 LAXÅ
SWEDENTel: + 46 584 81000Fax: + 46 584 411924
2SAFETY
Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who works on or near the equipment
observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of welding
equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace.
All work must be carried out by trained personnel well--acquainted with the operation of the welding equipment. Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment.
1.Anyone who uses the welding equipment must be familiar with:
S its operation
S location of emergency stops
S its function
S relevant safety precautions
S welding
2.The operator must ensure that:
S no unauthorized person is stationed within the working area of the equipment when it is started up.
S no--one is unprotected when the arc is struck
3.The workplace must:
S be suitable for the purpose
S be free from drafts
4.Personal safety equipment
S Always wear recommended personal safety equipment, such as safety glasses, flame--proof clothing, safety gloves.
S Do not wear loose--fitting items, such as scarves, bracelets, rings, etc., which could become trapped or cause burns.
5.General precautions
S Make sure the return cable is connected securely.
S Work on high voltage equipment may only be carried out by a qualified electrician.
S Appropriate fire extinquishing equipment must be clearly marked and close at hand.
bh26d1e
-- 3 --
GB
WARNING
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAUTIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE
BASED ON MANUFACTURERS’ HAZARD DATA.
ELECTRIC SHOCK -- Can kill
SInstall and earth the welding unit in accordance with applicable standards.
SDo not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
SInsulate yourself from earth and the workpiece.
SEnsure your working stance is safe.
FUMES AND GASES -- Can be dangerous to health
SKeep your head out of the fumes.
SUse ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone
and the general area.
ARC RAYS -- Can injure eyes and burn skin.
SProtect your eyes and body. Use the c orrect welding screen and filter lens and wear protective
clothing.
SProtect bystanders with suitable screens or curtains.
FIRE HAZARD
SSparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.
NOISE -- Excessive noise can damage hearing
SProtect your ears. Use earmuffs or other hearing protection.
SWarn bystanders of the risk.
MALFUNCTION -- Call for expert assistance in the event of malfunction.
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
PROTECT YOURSELF AND OTHERS!
ESAB can provide you with all necessary welding protection an d accessories.
WARNING!
Read and understand the instruction manual before installing
or operating.
WARNING!
Do not use the power source for thawing frozen pipes.
This product is solely intended for arc welding.
bh26d1e
Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and returned to an
environmentally compatible recycling facility. As the owner of the equipment, you should
get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human health!
-- 4 --
GB
3INTRODUCTION
The Arc 150i is a welding current power source intended for use with coated
electrodes (MMA welding) and TIG welding.
3.1Equipment
The Arc 150i is supplied with 3 m of mains cable and an instruction manual.
ESAB’s accessories for the product can be found on page 18.
4TECHNICAL DATA
Arc 150i
Mains voltage230 V, 1 μ 50/60 Hz
Fuse (delayed--action)16 A
Primary current I
Primary current I
Voltage/current range (DC)4 A /20 V -- 150 A /26 V
Maximum permissible load at
25% duty cycle
35% duty cycle
60% duty cycle
100% duty cycle
Power factor at maximum current0,62
Efficiency at maximum current77%
Open--circuit voltage71--78 V
Operating temperature-- 1 0 ˚C-- +40˚ C
Constant A--weighed sound pressure<70db
Dimensions, l x b x h394 x 267 x 274 mm
Weight9kg
Enclosure classIP 23C
Application class
max
eff
36 A
21 A
150 A / 26 V
140 A / 26 V
110A/25V
90 A / 24 V
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a certain load without overloading.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
Application class
The symbolindicates that the power source is designed for use in areas with increased
electrical hazard.
bh26d1e
-- 5 --
GB
5INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
Note!
Connect the power source to the electricity mains with a network impedance of 0.210 ohm or lower. If the
network impedance is higher, there is a risk of flicker in the illuminators.
5.1Placing
Place the power source so that its cooling air inlets and outlets are not obstructed.
5.2Rating plate
The rating plate is located on the underside of the power source.
5.3Mains power supply
Make sure that the welding power source is connected to the correct supply voltage
and that it is protected by the correct fuse rating. The standards for the country in
question must be complied with as regards the mains cable area. A protective earth
connection must be made in accordance with regulations.
5.3.1Recommended fuse sizes and minimum cable areas
*) Note! The installed plug is approved for max. 16A.
North American version: The mains cable is approved for maximun 18 A.
Note!
The cable area and fuse rating above comply with Swedish regulations. Use the welding power source
in accordance with the relevant national regulations.
bh26d1e