ESAB Bombardier Digipulse Dual Wire Feeders Instruction manual

Page 1
CRATER FILL OPTION
P/N 37377
INSTALLATION AND OPERATION
Bombardier Digipulse Dual Wire Feeders
(this kit is designed for the Bombardier Digipulse Dual Feeder only)
F-15-451
April, 1998
INSTALLATION (See Figure 1.)
1. Make sure control cable is disconnected from the Power Source or Digipulse Dual Wire Feeder.
2. Remove the cover of the Digipulse Dual control box.
3. Remove the plastic knock-out plug in the center of the Digipulse feeder front panel.
4. Position the Crater label (P/N 954754 supplied in kit) over the hole in the control front panel and press firmly in place.
5. Insert and mount the supplied crater toggle switch assembly in the front panel center hole using the hardware provided. Rotate the switch so that the white wire is on top (12 oclock) position and the blue wire at the bottom (6 oclock) position. See Figure #1 on reverse side.
6. Remove plug P6 from the MPU PC board and in­sert the white wire connector into plug terminal po­sition #14 (P6-14) . The wire connector will lock into position when inserted properly.
7. Insert the blue wire connector into terminal posi­tion #2 (P6-2) of plug P6. The wire connector will lock into position when inserted properly.
8. Connect the yellow wire with the spade connector to the terminal strip (T1-1) in the Digipulse Dual control box at position #1 (common).
9. Reconnect the P6 plug to the MPU PC board.
10. Remove EPROM 18090 from the MPU PC board and replace it with EPROM 99513606 supplied with the kit. EPROMs are static sensitive so handle with care. Note the orientation of the notched end of the EPROM. Notch should be facing left.
11. Replace wire feeder control cover and connect the control cable to Power Source.
OPERATION
The Crater Fill feature allows the operator to preset a special welding wire feed speed (IPM), arc length (VOLTS) and time (TIMES) to control the shape and size of the weld crater upon termination of the welding process.
Each weld schedule can be preset with a unique crater fill IPM and VOLTS condition but only one crater fill TIME can be programmed for each torch. The Digipulse Dual feeder can have 16 unique crater fill conditions and two unique crater fill times.
Note
When a crater TIME is programmed, the double click method of changing torch schedules by using the weld­ing torch trigger is automatically disabled for that torch.
Programming a Crater Condition
1. Momentarily depress the trigger of the torch to be programmed. Be sure the desired schedule num­ber is assigned to that torch. Schedules 1 - 4 are Pulse arc welding schedules and schedules 5 - 8 are Short Circuiting/Spray arc welding schedules.
2. Hold the Crater toggle switch in the TIMES posi­tion. The window corresponding to the torch be­ing used will illuminate. Simultaneously enter the desired crater time (in seconds) using the INC/DEC switch under the illuminated window. A zero (0) will disable the crater fill feature. For example, if the left torch trigger was depressed (see step #1) then the IPM window will illuminate.
3. Hold the Crater toggle switch in the CONDITIONS position and simultaneously enter the crater IPM and VOLTS settings desired using the INC/DEC toggle switches beneath their respective window.
4. During welding the crater fill schedule will be en­abled when the operator releases the torch trig­ger. The crater timer will start and the arc will ex­tinguish automatically when the preset crater time has timed out.
Be sure this information reaches the operator. You can get extra copies through your supplier.
Page 2
P6 Plug Position
Crater Toggle
Switch (950087)*
Label (954754)*
Location for EPROM (99513606)*
Digipulse Dual MPU Board
* Items supplied with
Crater Fill Kit, 37377.
End View of Plug P6
Crater Toggle Switch and Wiring
Terminal Strip T1
Figure 1
F-15-451 4/98 Printed in U.S.A.