ESAB A32, A33, A34 Caddy Instruction manual

US
Caddy
®
A32, A33, A34
Instruction manual
Valid from program version 1.030460 449 187 US 20120322
1 INTRODUCTION 3...................................................
1.1 Control panel A32 3.........................................................
1.2 Control panel A33 4.........................................................
1.3 Control panel A34 5.........................................................
2 SMAW WELDING 6..................................................
2.1 Settings 6..................................................................
2.2 Symbol and Function explanations 6...........................................
2.3 Hidden functions SMAW welding 7............................................
3 GTAW WELDING 8...................................................
3.1 Settings 8..................................................................
3.2 Symbol and Function explanations 8...........................................
4 WELDING DATA MEMORY 9..........................................
5 FAULT CODES 9....................................................
5.1 List of fault codes 10..........................................................
5.2 Fault code descriptions 10.....................................................
ORDERING NUMBER 11.................................................
TOCa
- 2 -
US
1 INTRODUCTION
The manual describes use of A32, A33 and A34 control panels.
For general information about operation see user's instructions for the power source.
When mains power is supplied the unit runs a self diagnosis of the LEDs and the display, the program version is displayed and in this example the program version is 0.18.
NOTE! Differences in the panel function may occur, depending on which product is installed.
Instruction manuals in other languages can be downloaded from the website, www.esab.com.
1.1 Control panel A32
Display
Knob for setting the current
Choice of welding method SMAW or GTAW
Setting from panel or connecting remote control unit
Display of VRD function (reduced open-circuit voltage) .
Measured value in the display for welding current A, is arithmetic average value = rectified average value.
bi20a
- 3 -
© ESAB AB 2008
US
1.2 Control panel A33
Display
Indication of which parameter is shown in the display (current or percent)
Knob for setting data (current or percent)
Buttons for weld data memory settings. See title 4 .
Button for choosing parameters ”Hot start” or arc pressure ”Arc force”
when SMAW-welding
Choice of welding method SMAW or GTAW
Setting from panel and connecting remote control unit
Display of VRD function (reduced open-circuit voltage) This function is not yet
fully supported.
Measured value in the display for welding current A, is arithmetic average value = rectified average value.
bi20a
- 4 -
© ESAB AB 2008
US
1.3 Control panel A34
Display
Indication of which parameter is shown in the display (current, voltage or
percent)
Display of measurement value for current (A) or voltage (V) during welding.
Knob for setting data (current or percent)
Buttons for settings in welding data memory. See title 4 .
Button for choosing parameters ”Hot start” or arc pressure ”Arc force”
when SMAW-welding
Choice of welding method SMAW or GTAW
Choice of electrode type ”Basic”, ”Rutile” or ”Cellulose” when SMAW-welding
Setting from panel and connecting remote control unit
Display of VRD function (reduced open-circuit voltage).
Measured value in the display for arc voltage V, and welding current A, is arithmetic average value = rectified average value.
bi20a
- 5 -
© ESAB AB 2008
US
2 SMAW WELDING
2.1 Settings
Function Setting range A32 A33 A34 Default
value
Current 4 A - max
Active panel OFF or ON x x x ON
Remote control unit OFF or ON x x x OFF
Hot start 0 - 99% x
Arc force 0 - 99% x
Drop welding OFF or ON x
VRD - x x x -
1)
The setting range is dependent on the power source used.
2)
Hidden function
1)
x x x 100
2)
2)
2)
x x 0
x x 5
2)
x
2)
x
OFF
2.2 Symbol and Function explanations
SMAW welding
SMAW welding may also be referred to as welding with coated electrodes. Striking the arc melts the electrode, and its coating forms protective slag.
Setting current
A higher current produces a wider weld pool, with better penetration into the workpiece.
Active panel
Settings are made from the control panel.
Remote control unit
Settings are made from the remote control unit.
The remote control unit must be connected to the remote control unit socket on the machine before activation. When the remote control unit is activated the panel is inactive.
Hot Start
Increases the welding current during a fixed time at the start of the welding process. Set the value of the hot start current by using the knob. This reduces the risk of incomplete fusion at the start of the weld.
bi20a
- 6 -
© ESAB AB 2008
US
Arc force
The arc force is important in determining how the current changes in response to a change in the arc length. A lower value gives a calmer arc with less spatter.
VRD (Voltage Reducing Device)
The VRD function ensures that the open-circuit voltage does not exceed 35 V when welding is not being carried out. This is indicated by a lit VRD LED.
The VRD function is blocked when the system senses that welding has started.
If the VRD function is activated and the open-circuit voltage exceeds the 35 V limit, this is indicated by an error message (16) appearing in the display and welding cannot be started whilst the error message is displayed.
Contact an authorised ESAB service technician to activate the function.
2.3 Hidden functions SMAW welding
There are hidden functions in the control panel.
To access the functions in A32, use the method button, .
To access the functions in A33 and A34, hold button depressed for 5 seconds. The display shows a letter and a value. The correct function is selected by pressing the buttons. The knob is used to change the value of the selected function.
Function letter Function
C Arc Force
H Hotstart
d Drop welding
To leave the function in A32, hold the button depressed for 5 seconds. For
A33 and A34, hold the button depressed for 5 seconds.
Arc force
The arc force is important in determining how the current changes in response to a change in the arc length. A lower value gives a calmer arc with less spatter.
bi20a
- 7 -
© ESAB AB 2008
US
Hot Start
Increases the welding current during a fixed time at the start of the welding process. Set the value of the hot start current by using the knob. This reduces the risk of binding defects at the start of the weld.
Drop welding
Drop welding can be used when welding with stainless electrodes. The function involves alternately striking and extinguishing the arc in order to achieve better control of the supply of heat. The electrode needs only to be raised slightly to extinguish the arc.
3 GTAW WELDING
3.1 Settings
Function Setting range A32 A33 A34 Default
value
Current 4 max
Active panel OFF or ON x x x ON
Remote control unit OFF or ON x x x OFF
VRD - x x x -
1)
The setting range is dependent on the power source used.
1)
x x x 60 A
3.2 Symbol and Function explanations
GTAW welding
GTAW welding melts the metal of the workpiece, using an arc struck from a tungsten electrode, which does not melt itself. The weld pool and the electrode are protected by shielding gas.
”LiveTig start”
With “LiveTig start” the arc strikes when the tungsten electrode is brought into contact with the workpiece and then lifted away from it.
bi20a
- 8 -
© ESAB AB 2008
US
Active panel
Settings are made from the control panel.
Remote control unit
Settings are made from the remote control unit.
The remote control unit must be connected to the remote control unit socket on the machine before activation. When the remote control unit is activated the panel is inactive.
VRD (Voltage Reducing Device)
The VRD function ensures that the open-circuit voltage does not exceed 35 V when welding is not being carried out. This is indicated by a lit VRD LED.
The VRD function is blocked when the system senses that welding has started.
If the VRD function is activated and the open-circuit voltage exceeds the 35 V limit, this is indicated by an error message (16) appearing in the display and welding cannot be started whilst the error message is displayed.
Contact an authorised ESAB service technician to activate the function.
4 WELDING DATA MEMORY
Two different welding data programs can be stored in the control panel memory.
Press button or for 5 seconds to store the welding data in the memory. The welding data is stored when the green indicator lamp starts to flash.
To switch between the different welding data memories press button or
.
The welding data memory has a back-up so that the settings remain even if the machine has been switched off.
5 FAULT CODES
Fault codes are used to indicate that a fault has occurred in the equipment. It is indicated in the display by an E followed by a fault code number.
A unit number is displayed to indicate which unit has generated the fault, for example U 0.
If several faults have been detected only the code for the last occurring fault is displayed. Press any function button or turn the knob to remove the fault indication from the display.
bi20a
- 9 -
© ESAB AB 2008
US
NOTE! If the remote control unit is activated, deactivate the remote control unit by
pressing to remove the fault indication.
5.1 List of fault codes
Unit number:
U 0 = welding data unit U 2 = power source
U 4 = remote control unit
5.2 Fault code descriptions
The fault codes that the user can correct themselves are given below. If a different code appears, call a service technician.
Fault code
E 6 High temperature
E 14 Communication error (bus off)
E 16 High open-circuit voltage
E 19 Memory error
Description
The thermal overload cut-out has tripped.
The current welding process is stopped and cannot be restarted until the temperature has fallen.
Action: Check that the cooling air inlets or outlets are not blocked or clogged with dirt. Check the duty cycle being used, to make sure that the equipment is not being overloaded.
Serious interference on the CAN bus.
Action: Check that there are no faulty units connected on the CAN bus. Check the cables. Send for a service technician if the fault persists.
Open circuit voltage has been too high.
Action: Turn off the mains power supply to reset the unit. Send for a service technician if the fault persists.
Content of existing memory is incorrect. Basic data will be used.
Action: Turn off the mains power supply to reset the unit. Send for a service technician if the fault persists.
bi20a
- 10 -
© ESAB AB 2008
A32, A33, A34
Ordering number
Ordering no. Denomination
0460 250 883 Control panel Caddyt A32
0460 250 888 Control panel Caddyt A33
0460 250 885 Control panel Caddyt A34
File name Denomination
0460 449 170 Instruction manual SE 0460 449 171 Instruction manual DK 0460 449 172 Instruction manual NO 0460 449 173 Instruction manual FI 0460 449 174 Instruction manual GB 0460 449 175 Instruction manual DE 0460 449 176 Instruction manual FR 0460 449 177 Instruction manual NL 0460 449 178 Instruction manual ES 0460 449 179 Instruction manual IT 0460 449 180 Instruction manual PT 0460 449 181 Instruction manual GR 0460 449 182 Instruction manual PL 0460 449 183 Instruction manual HU 0460 449 184 Instruction manual CZ 0460 449 185 Instruction manual SK 0460 449 186 Instruction manual RU 0460 449 187 Instruction manual US 0460 449 189 Instruction manual EE 0460 449 190 Instruction manual LV 0460 449 191 Instruction manual SI 0460 449 192 Instruction manual LT 0460 449 193 Instruction manual CN
Instruction manuals are available on the Internet at www.esab.com
- 11 -
bi20o
© ESAB AB 2008
ESAB Welding & Cutting Products, Florence, SC Welding Equipment
COMMUNICATION GUIDE - CUSTOMER SERVICES
A CUSTOMER SERVICE QUESTIONS:
Telephone: (800) 362-7080 / Fax: (800) 634-7548 Hours: 8.00 AM to 7:00 PM EST
Order Entry Product Availability Pricing Order Information Returns
B ENGINEERING SERVICE:
Telephone: (834) 664-4416 / Fax: (800) 446-5693 Hours: 7.30 AM to 5:00 PM EST
Warranty Returns Authorized Repair Stations Welding Equipment Troubleshooting
C TECHNICAL SERVICE:
Telephone: (800) ESAB-123 / Fax: (843) 664-4452 Hours: 8.00 AM to 5:00 PM EST
Part Numbers Technical Applications Specifications Equipment Recommendations
D LITERATURE REQUESTS:
Telephone: (843) 664-5562 / Fax: (843) 664-5548 Hours: 7.30 AM to 4:00 PM EST
E WELDING EQUIPMENT REPAIRS:
Telephone: (843) 664-4487 / Fax: (843) 664-5557 Hours: 7.30 AM to 3:30 PM EST
Repair Estimates Repair Status
F WELDING EQUIPMENT TRAINING:
Telephone: (843) 664-4428 / Fax: (843) 679-5864 Hours: 7.30 AM to 4:00 PM EST
Training School Information and Registrations
G WELDING PROCESS ASSISTANCE:
Telephone: (800) ESAB-123 Hours: 7.30 AM to 4:00 PM EST
H TECHNICAL ASST. CONSUMABLES:
Telephone: (800) 933-7070 Hours: 7.30 AM to 5:00 PM EST
IF YOU DO NOT KNOW WHOM TO CALL
Telephone: (800) ESAB-123
Fax: (843) 664-4452
Hours: 7:30 AM to 5:00 PM EST
20120322
or
visit us on the web at http://www.esabna.com
The ESAB web site offers:
Comprehensive Product Information
Material Safety Data Sheets
Warranty Registration
Instruction Literature Download Library
Distributor Locator
Global Company Information
Press Releases
Customer Feedback & Support
ESAB Welding & Cutting Products
PO BOX 100545, Florence SC 29501-0545
backp3us
- 12 -
© ESAB AB 2008
Loading...