Symbols used in this manual__________________________________ 42
Importance of this manual ___________________________________ 42
Envisaged use ______________________________________________ 42
Installer's qualifications ______________________________________ 42
Automatic safety elements ___________________________________ 42
Description of the product43
Elements of the complete installation __________________________ 43
Operator features___________________________________________ 44
Functioning modes _________________________________________ 45
Obstacle detection functioning _______________________________ 45
Manual drive_______________________________________________ 46
Declaration of Conformity ___________________________________ 46
Tools and materials _________________________________________ 48
Initial conditions and checks __________________________________ 48
Installing the operator _______________________________________ 49
Electrical connections _______________________________________ 51
Programming and startup53
Connection to the power supply and checking of turning direction _ 53
Controls and commands _____________________________________ 53
Radio code programming (for RSD only)________________________ 55
Total open/close programming________________________________ 56
Pedestrian open/close programming ___________________________ 57
Selection of modes and control panel functions (SW) _____________ 57
Potentiometer adjustment ___________________________________ 58
Starting up ________________________________________________ 58
This manual uses symbols to highlight specific texts. The
functions of each symbol are explained below:
SYMBOLS USED IN THIS MANUAL
Failure to respect the safety warnings could
lead to accident or injury.
O Instructions which must be followed to prevent
deterioration.
2
IMPORTANCE OF THIS MANUAL
Read this guide in its entirety before carrying
out the installation, and obey all instructions.
Failure to do so may result in a defective
installation, leading to accidents and failures.
3
This device has been designed for installation as part of
an automatic opening and closing system for sliding
doors and gates.
ENVISAGED USE
This device is not suitable for installation in
inflammable or explosive environments.
Work sequences or procedures.
Important details which must be respected for
correct assembly and operation.
Additional information to help the installer.
} Information on care for the environment.
Moreover, this guide provides valuable information
which will help you to carry out installation more
efficiently.
This manual is an integral part of the product. Keep
for future reference.
Failure to install or use as indicated in this
manual is inappropriate and hazardous, and
could lead to accidents or failures.
The installer shall be responsible for ensuring
the facility is set up for its envisaged use.
4
INSTALLER'S QUALIFICATIONS
Installation should be completed by a professional installer, complying with the following
requirements:
• He/she must be capable of carrying out
mechanical assemblies in doors and gates,
choosing and implementing attachment
systems in line with the assembly surface
(metal, wood, brick, etc) and the weight and
effort of the mechanism.
• He/she must be capable of carrying out
simple electrical installations in line with the
low voltage regulations and applicable
standards.
Installation should be carried out bearing in mind standards EN 13241-1 and EN 12453.
5
This device complies with all current safety regulations.
However, the complete system comprises, apart from
the operator referred to in these instructions, other
elements which should be acquired separately.
The safety of the complete installation depends on
AUTOMATIC SAFETY ELEMENTS
all the elements installed. Install only Erreka
components in order to guarantee proper
operation.
Respect the instructions for all the elements
positioned in the installation.
We recommend installing safety elements.
For further details, see “Fig. 1 Elements of the
complete installation” on page 43.
42 Installation Manual
Seguridad_95.fm - 19/12/11
DESCRIPTION OF THE PRODUCT
English
1
ELEMENTS OF THE COMPLETE INSTALLATION
1Gate
2Rack
3Operator with control panel
4Magnetic key or proximity key reader
5Wall pushbutton/key switch
6Antenna
7Closing safety photocells
8Limit switch magnets
9Mechanical strip
10 Traffic light
ELECTRICAL CABLING:
ElementNº threads x sectionMaximum length
A: Main power supply3x1.5mm
B: Flashing light2x0.5mm
C: Photocells (Tx / Rx)2x0.5mm
D: Pushbutton/wall key2x0.5mm
E: AntennaCoaxial cable 50
Fig. 1Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
11 Flashing light
12 Gate stopper (with spring)
2
2
2
/ 4x0.5mm
2
2
k (RG-58/U)5m
For greater safety, Erreka recommends installing
photocells (7) and safety strips (9).
30m
20m
30m
50m
Descripcion_145.fm - 26/4/11
PUMA operator for sliding gates43
DESCRIPTION OF THE PRODUCT
2
ModelPUS400ECPUS400ECM
Power supply (V/Hz)230/50125/60
Absorbed current (A)1,22,4
Power consumed (W)280280
Capacitor (μF)820
Protection class (IP)4444
Maximum torque (Nm)1212
Maximum speed (m/min)1012
LockingYesYes
Operating temperature (ºC)-20 / +55-20 / +55
Duty cycle S3 (%)2525
Weight (Kg)99
Maximum weight of gate (kg)400400
OPERATOR FEATURES
General features
PUMA operators are constructed to form part of a
sliding gate automation system.
This operator, with built-in control panel, is equipped
with a slowdown system which reduces speed at the
end of the opening and closing operations, in order
to prevent impacts and bangs to the gate.
This operator allows us to fulfil the requirements of
standard EN 12453 without the use of peripheral
elements.
• Power supply (earthed):
PUS400EC: 230Vac/50Hz
PUS400ECM: 125Vac/60Hz
• Control of open/close by way of encoder
• Adjustable maximum thrust
• Adjustable standby time in automatic cycle
Notable features
Flashing light
The light remains on during the opening and closing
operations.
The light goes off when the operation finishes. The light
goes off whenever operation is interrupted at an
intermediate point.
Operation advance warning function
(DIP2=ON)
This function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn us that operation is about to begin.
• Closing safety device cable connectors (photocells or
mechanical strips)
• Cable connector for emergency stop pushbutton
(STOP)
• Connector for plug-in receiver
• Connector for traffic light card
• 24Vdc cable connector for peripheral connection
Slowdown function (DIP 8=ON)
Function which reduces the speed of the motor at the
end of the opening and closing operation.
STOP pushbutton (emergency stop)
This control panel allows an emergency stop
pushbutton to be installed (STOP). This pushbutton is of
NC type (normally closed). The opening of this contact
produces the immediate halting of the gate.
Traffic light
A plug-in receiver can be connected if the AEPS1-001
card is installed. Using colour lights, these will indicate
the suitability or otherwise of crossing the gate.
• Off: gate closed
• Green light: gate open, free passage
• Red light: gate in movement, passage forbidden
• Flashing green light: open gate about to close (in
automatic mode)
44 Installation Manual
Descripcion_145.fm - 26/4/11
DESCRIPTION OF THE PRODUCT
3
FUNCTIONING MODES
Automatic mode (DIP4=ON)
Opening: this begins by activating the key command
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
command is activated during opening, the gate
comes to a halt. The gate closes if operated again.
• Collective opening (DIP3=OFF): during opening,
the control panel does not obey the key commands.
Step-by-step mode (DIP4=OFF)
Opening: this begins by activating the key command
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
command is activated during opening, the gate
comes to a halt. The gate closes if operated again.
• Collective opening (DIP3=OFF): during opening,
the control panel does not obey the key commands.
Standby: the gate remains open during the
programmed time.
• Automatic mode optional (only if DIP5=ON): if,
during standby, the key command is activated, the
gate begins to close.
• Non-automatic mode optional (DIP5=OFF): if,
during standby, the key command or the photocell
is enabled, standby time starts again.
Closing: the closing operation starts once stand-by
time is finished.
If, during closing, the key command is activated, the
gate stops and then inverts operation direction and
opens completely.
Standby: the gate remains open until a key command
is received.
Close: the closing process begins by running the key
command (transmitter, magnetic key, key switch, etc).
If, during closing, the key command is activated, the
gate stops and then inverts operation direction and
opens completely.
4
The gate can detect an obstacle in two ways:
A-
OBSTACLE DETECTION FUNCTIONING
Detection by photocell or strip
Closing safety device (SG.C)
During opening: the closing safety device (SG.C.) does
not run.
B-Direct detection (built-in safety) (DIP7=ON)
During opening
If, during opening, the gate collides with an obstacle,
the gate inverts the operation direction and gently
closes, remaining on standby until a new key command
is received.
During closing: if, during closing, the closing safety
device (SG.C) is enabled, the gate inverts operation
direction and opens completely.
During closing
If, during closing, the gate collides with an obstacle, it
inverts operation direction and opens completely.
Descripcion_145.fm - 26/4/11
PUMA operator for sliding gates45
DESCRIPTION OF THE PRODUCT
5
In the event of need, the gate may be operated manually:
Unlocking for manual operation
MANUAL DRIVE
Motorised operation locking
1 Turn the cover (1) 180º to reveal the cylinder.
2 Introduce the key (2) and turn clockwise
without forcing it.
The cylinder will protrude a few millimetres,
pushed by a spring.
3 Turn the handle (3) anti-clockwise 270º until it
reaches the stopper, without forcing it.
3
The gate can now be operated manually.
1 Turn the handle (3) anti-clockwise 270º until it
reaches the stopper, without forcing it. Turn
the key anti-clockwise and remove it.
2 Push the cylinder (4) inwards and turn the cover
(1) to cover it.
3 Move the gate manually until the operator
locks.
3
6
Erreka Automatismos declares that the PUMA operator
has been designed for use in a machine or for assembly
along with other elements in order to form a machine
in line with Directive 89/392 EEC and successive
modifications.
The PUMA operator allows us to carry out installations
in line with the standards EN 13241-1 and EN 12453.
46 Installation Manual
DECLARATION OF CONFORMITY
The PUMA operator complies with safety legislation in
line with the following directives and standards:
• 73/23 EEC and successive modification 93/68 EEC
• 89/366 EEC and successive modifications 92/31 EEC
and 93/68 EEC
• UNE-EN 60335-1
Descripcion_145.fm - 26/4/11