ERNITEC BDR-510/2, BDR-514/2 Installation Instruction

Installation Instruction
for BDR-510/2 & BDR-514/2
Digital Camera Stations
3020-00025 / 98.02.19
1 Introduction
1.1 ERNA Format:
The BDR-510/2 and BDR-514/2 are controlled via the ERNA protocol (Ernitec Asynchronious Serial One-way Camera Control). With this camera control protocol it is possible to use standard modems between a system and a camera station (or between two BDR-5XX) if the distance is more than 1200 meter. The new ERNA protocol can be generated from a PC, which means that camera control can be made via the PC's RS-232-C port. The format of this protocol is as follows (Version 2.0, Release 961016):
1.1.1 Physical format:
Baudrate = 2400 Parity Bit = None Data Bit = 8 Stop Bit = 1
1.1.2 Frame format:
Header Address Command Data 1 Data 2 Checksum
STX 0-255 1-17 0-255 0-255 Sum of previous bytes
02 Hex 255=Broadcast
Installation Manual
Page 2 3020-00025
1.1.3 Commands:
Comman
d
Function Data 1 Description Data 2 Description CS Type
1 Relays 0-255 Bit 0 Pan right
1 Pan left 2 Tilt up 3 Tilt down 4 Zoom wide 5 Zoom tele 6 Focus near 7 Focus far
0-255 Bit 0 Iris open
1 Iris close 2 AUX1 3 AUX2 4 AUX3 5 AUX4 6 AUX5 7 AUX6
ALL
2 Call preposition 1-128 Prepos number ---- Not used BDR-55X/575 3 Start Sequence prepos 0 ---- Not used 55x/575/ICU
4 Text on/off 0 ---- Not used BDR-55x 5 Save prepos 1-128 Prepos number ---- Not used 55x/575/ICU 6 Insert prepos in stack 1-128 Prepos number ---- Not used 55x/575/ICU 7 Delete prepos from stack 1-128 Prepos number ---- Not used 55x/575/ICU 8 Clear seq. stack 0 ---- Not used 55x/575/ICU 9 Show seq. stack 0 ---- Not used BDR-55x
10 Latch AUX 0-255 Bit 2 AUX1
3 AUX 2 4 AUX 3 5 AUX 4 6 AUX 5 7 AUX 6 Low=Latch High=No latch
---- Not used BDR-55x
11 Sequence dwelltime 0-255 Seconds ---- Not used 55x/575/ICU 12 Homepos 0-255 Prepos number
0=Disabled
0-255 10*1sec time-out 55x/575/ICU
13 AUX on/ off 1-8 Relay number 0-1 0=Off 1=On 55x/575/ICU 14 PT Speed 0-255 Pan Speed 0-255 Tilt Speed BDR-575/ICU 15 Auto-paning 1 Speed 0-255 BDR-575/ICU
2 Limits 1/2 3 Start 0
16 Camera Set-up 1 Mode 0-255 Bit 0 Gain Ctrl. remote.
1 White bal. remote. 2 Contour corr. remote. 3 Shutter speed remote. 4 Gain auto. 5 White val. auto.
ICU
2 Gain control. 0-255 0=low 255=high 3 White balance. 0-255 0=Warm 255=Cold 4 Contour corr. 0-255 0=Sharp 255=Soft 5 Shutter speed 0-255 0=Fast 255=Slow 6 Background comp. 0 Not used
Installation Manual
3020-00025 Page 3
Comman
d
Function Data 1 Description Data 2 Description CS Type
17 Alarms 1 Configuration 0-255 Bit 0 Alarm 1
0=NC 1=NO 1 Alarm 2 0=NC 1=NO 2 Alarm 1 relay 0=Off 1=On 3 Alarm 2 0=Off 1=On 4 Alarm 1 priority 0=Low 1=High 5 Alarm 2 0=Low 1=High 6 Alarm 1 0=Disable 1=Enable 7 ALarm 2 0=Disable 1=Enable
ICU
3 Alarm 1 Set-up 0-255 Bit 0-5 Preposition
6 Relay 1 0=Disable 1=Enable 7 Relay 2 0=Disable 1=Enable
2 Alarm 2 Set-up 0-255 Bit 0-5 Preposition
6 Relay 1 0=Disable 1=Enable 7 Relay 2 0=Disable 1=Enable
Installation Manual
Page 4 3020-00025