![](/html/bf/bf31/bf31251fde2fa5fe2e7ff255d84de460c1dc59bca5076bded8d4c501d326caed/bg1.png)
Installation Instruction
for BDR-510/2 & BDR-514/2
Digital Camera Stations
![](/html/bf/bf31/bf31251fde2fa5fe2e7ff255d84de460c1dc59bca5076bded8d4c501d326caed/bg2.png)
1 Introduction
A Digital Camera Station forms the receiver end of a digital remote control system. A digital
remote control system is used to control camera functions such as pan, tilt, zoom, focus and
iris, light on/off and open/close gates etc..
A digital remote control system has the advantage of long transmission distance and low cable
installation cost due to the fact that a standard 2 x 0.6 mm twisted pair cable may be used for
the control of up to 12 functions.
The Digital Camera Stations BDR-510/2 and BDR-514/2 is designed with special attention to
transmission safety and stability.
The BDR-510/2 and BDR-514/2 camera stations are addressable which means that up to 64
units can be controlled via one twisted pair line.
The BDR-510/2 and BDR-514/2 are delivered as self-contained units with a mains change-over
switch for selection between 230 VAC and 115 VAC mains voltage.
The BDR-510/2 and BDR-514/2 is housed in an IP65 rated ABS-box and can be used in
connection with SYSTEM 500M and SYSTEM 1000M. Besides the BDR-510/2 and BDR-514/2
can be controlled and programmed directly from the keyboards 1500M, 1501M, 1502M and
1503M.
1.1 ERNA Format:
The BDR-510/2 and BDR-514/2 are controlled via the ERNA protocol (Ernitec Asynchronious
Serial One-way Camera Control).
With this camera control protocol it is possible to use standard modems between a system and
a camera station (or between two BDR-5XX) if the distance is more than 1200 meter.
The new ERNA protocol can be generated from a PC, which means that camera control can be
made via the PC's RS-232-C port.
The format of this protocol is as follows (Version 2.0, Release 961016):
1.1.1 Physical format:
Baudrate = 2400
Parity Bit = None
Data Bit = 8
Stop Bit = 1
1.1.2 Frame format:
Header Address Command Data 1 Data 2 Checksum
STX 0-255 1-17 0-255 0-255 Sum of previous bytes
02 Hex 255=Broadcast
Installation Manual
Page 2 3020-00025
![](/html/bf/bf31/bf31251fde2fa5fe2e7ff255d84de460c1dc59bca5076bded8d4c501d326caed/bg3.png)
1.1.3 Commands:
Comman
d
Function Data 1 Description Data 2 Description CS Type
1 Relays 0-255 Bit 0 Pan right
1 Pan left
2 Tilt up
3 Tilt down
4 Zoom wide
5 Zoom tele
6 Focus near
7 Focus far
0-255 Bit 0 Iris open
1 Iris close
2 AUX1
3 AUX2
4 AUX3
5 AUX4
6 AUX5
7 AUX6
ALL
2 Call preposition 1-128 Prepos number ---- Not used BDR-55X/575
3 Start Sequence prepos 0 ---- Not used 55x/575/ICU
4 Text on/off 0 ---- Not used BDR-55x
5 Save prepos 1-128 Prepos number ---- Not used 55x/575/ICU
6 Insert prepos in stack 1-128 Prepos number ---- Not used 55x/575/ICU
7 Delete prepos from stack 1-128 Prepos number ---- Not used 55x/575/ICU
8 Clear seq. stack 0 ---- Not used 55x/575/ICU
9 Show seq. stack 0 ---- Not used BDR-55x
10 Latch AUX 0-255 Bit 2 AUX1
3 AUX 2
4 AUX 3
5 AUX 4
6 AUX 5
7 AUX 6
Low=Latch
High=No latch
---- Not used BDR-55x
11 Sequence dwelltime 0-255 Seconds ---- Not used 55x/575/ICU
12 Homepos 0-255 Prepos number
0=Disabled
0-255 10*1sec time-out 55x/575/ICU
13 AUX on/ off 1-8 Relay number 0-1 0=Off 1=On 55x/575/ICU
14 PT Speed 0-255 Pan Speed 0-255 Tilt Speed BDR-575/ICU
15 Auto-paning 1 Speed 0-255 BDR-575/ICU
2 Limits 1/2
3 Start 0
16 Camera Set-up 1 Mode 0-255 Bit 0 Gain Ctrl. remote.
1 White bal. remote.
2 Contour corr. remote.
3 Shutter speed
remote.
4 Gain auto.
5 White val. auto.
ICU
2 Gain control. 0-255 0=low 255=high
3 White balance. 0-255 0=Warm 255=Cold
4 Contour corr. 0-255 0=Sharp 255=Soft
5 Shutter speed 0-255 0=Fast 255=Slow
6 Background comp. 0 Not used
Installation Manual
3020-00025 Page 3
![](/html/bf/bf31/bf31251fde2fa5fe2e7ff255d84de460c1dc59bca5076bded8d4c501d326caed/bg4.png)
Comman
d
Function Data 1 Description Data 2 Description CS Type
17 Alarms 1 Configuration 0-255 Bit 0 Alarm 1
0=NC 1=NO
1 Alarm 2
0=NC 1=NO
2 Alarm 1 relay
0=Off 1=On
3 Alarm 2
0=Off 1=On
4 Alarm 1 priority
0=Low 1=High
5 Alarm 2
0=Low 1=High
6 Alarm 1
0=Disable 1=Enable
7 ALarm 2
0=Disable
1=Enable
ICU
3 Alarm 1 Set-up 0-255 Bit 0-5 Preposition
6 Relay 1
0=Disable 1=Enable
7 Relay 2
0=Disable 1=Enable
2 Alarm 2 Set-up 0-255 Bit 0-5 Preposition
6 Relay 1
0=Disable 1=Enable
7 Relay 2
0=Disable 1=Enable
Installation Manual
Page 4 3020-00025