Erie water treatment pHneutralizer Series Technical Manual

© 2014 erie water treatment TM-EN-pHneutralizer-Rev2014.06
Technical Manual
WATER FILTER - pH correction
TABLE OF CONTENT
Page 2
Table of content ...................................................................................................................Page 2
Warning & Safety instructions ..............................................................................................Page 3
Operating conditions & Requirements .................................................................................Page 4
Assembly..............................................................................................................................Page 5
Installation ...........................................................................................................................Page 6
Start-up ................................................................................................................................Page 7
Electronic control panel .......................................................................................................Page 8
Maintenance ........................................................................................................................Page 12
Hydraulic flow diagrams .......................................................................................................Page 14
Troubleshooting ...................................................................................................................Page 15
Electrical wiring diagram ......................................................................................................Page 16
Default parameter settings ..................................................................................................Page 17
Exploded view - System ........................................................................................................Page 18
Exploded view - Timer head .................................................................................................Page 20
Exploded view - Valve body ..................................................................................................Page 22
Technical data ......................................................................................................................Page 24
WARNING & SAFETY INSTRUCTIONS
Page 3
Before you begin the installation of the water filter, we advise you read
and carefully follow the instructions contained in this manual. It contains important information about safety, installation, use and maintenance of the product. The actual system that you have received, may differ from the pictures/illustrations/descriptions in this Technical Manual.
Failure to follow the instructions could cause personal injury or damage
to the appliance or property. Only when installed, commissioned and serviced correctly, the water filter will offer you many years of trouble­free operation.
The water filter is intended to improve certain parameters of the water.
The water filter will not purify polluted water or make it safe to drink!
Installation of the water filter should only be undertaken by a competent
person, aware of the local codes in force. All plumbing and electrical connections must be done in accordance with local codes.
Before setting up the water filter, make sure to check it for any externally
visible damage; do not install or use when damaged.
Use a hand truck to transport the water filter. To prevent accident or
injury, do not hoist the water filter over your shoulder. Do not lay the water filter on its side.
Keep these Instructions in a safe place and ensure that new users are
familiar with the content.
The water filter is designed and manufactured in accordance with current
safety requirements and regulations. Incorrect repairs can result in unforeseen danger for the user, for which the manufacturer cannot be held responsible. Therefore repairs should only be undertaken by a competent technician, familiar and trained for this product.
In respect of the environment, this water filter should be disposed of in
accordance with Waste Electrical and Electronic Equipment requirements. Refer to national/local laws and codes for correct recycling of this water filter.
OPERATING CONDITIONS & REQUIREMENTS
Page 4
APPLICATION LIMITATIONS:
incoming pH: pHneutralizer: 6,0 - 7,0 pHneutralizerXL: 5,0 - 6,0
If the pH of the incoming water is below the stated levels, insufficient correction of the pH may occur, i.e. the pH at the outlet of the water filter may not be raised as expected.
incoming hardness: max. 100 mg/L as CaCO3 (= 10 °f or 5,6 °dH); at higher
hardness levels the water filter will still function, but the filter media will become ‘caked’, reducing its lifespan; increasing the regeneration frequency (i.e. reducing the number of days between 2 regenerations) may prevent this from happening.
outgoing hardness: as a result of the dissolution of the filter media, the water
hardness at the outlet of the filter will increase; a water softener may become necessary.
OPERATING PRESSURE: min. 2,0 / max. 8,3 bar
this system is configured to perform optimally at an operating pressure of 3
bar (±½ bar); in case of a higher operating pressure the performance may be affected negatively!
if installed on a well, verify that the well pump is powerful enough to provide
sufficient flow rate for the regeneration cycle.
check water pressure regularly. install a pressure reducer ahead of the water filter if necessary.
OPERATING TEMPERATURE: min. 4 / max. 38 °C
do not install the water filter in an environment where high ambient
temperatures (e.g. unvented boiler house) or freezing temperatures can occur.
the water filter cannot be exposed to outdoor elements, such as direct sunlight
or atmospheric precipitation.
do not install the water filter too close to a water heater; keep at least 3 m of
piping between the outlet of the water filter and the inlet of the water heater; water heaters can sometimes transmit heat back down the cold pipe into the control valve; always install a check valve at the outlet of the water filter.
ELECTRICAL CONNECTION: 230V-50Hz
this water filter only works on 24VAC; it is equipped with a 230/24V-50Hz
transformer; always use it in combination with the supplied transformer.
make sure to plug the transformer into a power outlet, which is installed in a
dry location, with the proper rating and over-current protection.
ASSEMBLY
Page 5
For ease of transportation and installation, the filter
media is NOT loaded in the pressure tank, but delivered in separate bags of 1 Cuft; it must be loaded on-site, after positioning of the pressure tank.
The gravel underbedding is already preloaded in the
pressure tank.
FILTER MEDIA LOADING
1. Move the pressure tank to the correct installation location; position it on a flat and level surface. Make sure to leave enough space for ease of service.
2. Position the riser assembly upright and centred in the pressure tank; plug the top of the riser tube with a piece of tape or clean rag, to prevent filter media from entering the tube.
3. Place a funnel on the pressure tank opening and fill the pressure tank with the filter media; make sure the riser assembly remains centered in the pressure tank.
4. Rinse the pressure tank opening to remove any filter media from the threaded section.
5. Unplug the top of the riser tube.
CONTROL VALVE
6. Make sure the O-ring in the riser insert and the tank O­ring (around the threaded section of the control valve) are in the correct position.
7. Screw the top distributor onto the control valve.
8. Lubricate the threaded section of the pressure tank, the top of the riser tube and the tank O-ring of the control valve; use a silicon-based lubricant.
9. Lower the control valve straight down onto the riser tube, until the riser tube is correctly inserted in the riser insert; then push it down firmly and screw it onto the pressure tank.
INSTALLATION
Page 6
INLET & OUTLET
Check the water pressure at the place of installation of
the water filter; it should never exceed 8,3 bar.
We strongly recommend the use of flexible hoses to
connect the water filter to the water distribution system; use hoses with a large diameter in order to limit the pressure loss.
If the water filter is not equipped with the factory bypass
(optional), we strongly recommend to install a 3-valve bypass system (not included with this product!) to isolate the water filter from the water distribution system in case of repairs. It allows to turn off the water to the water filter, while maintaining (untreated) water supply to the user.
WITH FACTORY BYPASS (optional)
Picture 1
= mains water supply (untreated water) = inlet of water filter (untreated water) = outlet of water filter (treated water) = house/application (treated water)
1. Screw the factory bypass onto the in/out ports on the control valve (&); make sure to install the gasket seals. Tighten the nuts firmly by hand.
2. Screw the connection kit with nuts onto the factory bypass (&); make sure to install the gasket seals. Tighten the nuts firmly by hand.
3. Connect the mains water supply to the adaptor on the inlet port of the factory bypass ().
4. Connect the house/application to the adaptor on the outlet port of the factory bypass ().
WITH 3-VALVE BYPASS SYSTEM (not included)
Picture 2
= inlet of water filter (untreated water) = outlet of water filter (treated water)
1. Install the 3-valve bypass system.
2. Screw the connection kit with nuts onto the in/out ports on the control valve (&); make sure to install the gasket seals. Tighten the nuts firmly by hand.
3. Connect the 3-valve bypass system to the adaptors on the in () and out () port of the control valve.
4. Connect the mains water supply to the inlet of the 3-valve bypass system ().
5. Connect the house/application to the outlet of the 3-valve bypass system ().
DRAIN
We recommend the use of a stand pipe with air trap. To prevent backflow from the sewerage system into the
water filter, always install and use the included air gap with double hose barb, to connect the drain hose to the sewerage system.
Lay-out the drain hose in such a way that pressure loss
is minimized; avoid kinks and unnecessary elevations.
Make sure that the sewerage system is suitable for the
rinse water flow rate of the water filter.
Picture 3
1. Install the air gap to the sewerage system; it fits over a 32 mm pipe or inside a 40 mm pipe adaptor. Ensure a permanent and watertight connection.
2. Connect a 13 mm hose to the drain connection of the control valve (); secure it by means of a clamp.
3. Run the drain hose to the air gap and connect it to one of the hose barbs; secure it by means of a clamp. This drain line operates under pressure, so it may be installed higher than the water filter.
ELECTRICAL
Picture 4
1. Plug the transformers output lead into the socket on the control valves power cord; secure it by means of the TwistLock clamp.
2. Plug the transformer into an electrical outlet.
START-UP
Page 7
PRESSURIZING
1. Make sure the bypass system is in 'bypass' position.
2. Make sure the electronic controller of the water filter is in service mode.
3. Open the mains water supply.
4. Open a cold treated water faucet nearby the water filter and let the water run for a few minutes until all air is purged and all foreign material that may have resulted from the installation is washed out; close the tap.
5. Gently pressurize the water filter, by putting it into service:
factory bypass:
1. open the 'outlet' valve;
2. slowly open the 'inlet' valve.
3-valve bypass:
1. close the 'bypass' valve;
2. open the 'outlet' valve;
3. slowly open the 'inlet' valve.
6. After 2-3 minutes, open a cold treated water faucet nearby the water filter and let the water run until all air is purged from the installation and the filter media is properly rinsed (it is normal for the rinse water to show some discoloration!); let the water run until the rinse water is clear; close the tap.
7. Check the water filter and all hydraulic connections for leaks.
Calcium/magnesium will be added to the water when it
passes through the water filter, to raise its pH. As a consequence the hardness of the treated water will be raised also!
ELECTRONIC CONTROL PANEL
8. Program the electronic controller.
PERFORM REGENERATION
9. Manually initiate a regeneration, by pressing the scroll  button repeatedly until the display shows:
10. Leave the water filter in this position; the countdown timer will countdown to 0 sec and start a regeneration.
Regen in 10 sec
ELECTRONIC CONTROL PANEL
Page 8
Picture 5
symbol
button
function
SCROLL
to advance to the next
parameter
UP
to increase the value of the
parameter
DOWN
to decrease the value of the
parameter
POWER-UP
After power-up, the power LED will light up and the display will show the installed software version, f.e.:
After 5 seconds, it will automatically revert back to the service mode.
POWER FAILURE
In the event of a power failure, the program will remain stored in the NOVRAM® during an undefined period, while an incorporated SuperCap (capacitor) will maintain the correct time of day during a period of several hours; consequently, in case of prolonged power failure, the time of day might not be maintained; if this happens, the time of day will be reset to 8:00 when the power supply is re-established, while the indication will flash, indicating that the time of day needs to be set.
When the power failure occurs during the execution of an automatic regeneration, the control valve will remain in its last position; when the power supply is re-established, the control valve will return to the service position, stay there for 60 sec. and restart a complete regeneration from the beginning.
TIMER FAILURE
In the event of a timer failure, the display will show the message:
If powering off/on the water filter doesn’t solve this problem, professional service is required.
SERVICE MODE
In service mode the display shows the time of day and the number of days remaining until the next regeneration:
REGENERATION MODE
In regeneration mode the display shows the remaining regeneration time and the remaining cycle time:
The control valve can be reset to service mode at any time by pressing the scroll  button, as such manually advancing it through the regeneration cycles.
MANUAL REGENERATION
It is possible to manually initiate a regeneration.
1. Press the scroll  button repeatedly until the display shows:
If the control valve is left in this position, the
countdown timer will countdown to 0 sec and start a regeneration.
To cancel this mode, press the scroll  button before
the countdown timer has reached 0 sec; the control valve will return to the service mode.
2. Press the scroll  button again if you want to manually advance the control valve to the next regeneration cycle.
DRIVE MOTOR SPEED
The drive motor of the control valve, that drives the valve body to its different regeneration positions, will start-up at low speed to reduce its noise level. To increase the speed of the drive motor, simply press the scroll  button as soon as the drive motor is activated.
Service Required
Rgn:123 CycY:456
EZRFTg EZ Rot0.8
8:00
7 DAY REM
Regen in 10 sec
20:51 7 DAY REM
ELECTRONIC CONTROL PANEL
Page 9
PROGRAMMING INSTRUCTIONS –
INSTALLER
Before entering the programming mode, make sure that
the control valve is in the service mode.
1. Press the scroll  button; the display will show:
Press the up  or down button to set the
language.
2. Press the scroll  button again; the display will show:
Press the up  or down button to set the time of
day.
3. Press the scroll  button again; the display will show:
Press the up  or down button to set the number
of days between regenerations.
The regeneration cycle is necessary to prevent ‘caking’
of the filter media during the service cycle, which may result in an increase of pressure drop over the water filter. Typically a regeneration every 7 days should be sufficient. In case of high flow rates, excessive water usage or a high concentration of impurities in the incoming water, it may be necessary to lower the number of days between regenerations.
Language:English
Set time: 20:51
Interval:7 Days
ELECTRONIC CONTROL PANEL
Page 10
PROGRAMMING INSTRUCTIONS -
PARAMETER SET LEVEL
All configuration parameters on this water filter have
been pre-programmed in the factory, to offer optimal performance in a wide range of applications and situations. See table at the end of this manual for default factory parameter settings. Nevertheless it may be necessary or desirable to change any of these parameters, to further optimize the water filters performance or to adapt it to the specific requirements of the installation.
Before entering the programming mode, make sure that
the control valve is in the service mode.
1. Press the scroll  button and hold it for 5 sec until the display shows:
2. Within 10 sec, press the up  button; the display will show:
Press the up  or down button to set the length
of the regeneration cycle.
Press the scroll  button again to advance to the next
regeneration cycle.
Cycle 1
Backwash
Cycle 2
Purge
3. Press the scroll  button again; the display will show:
Press the up  or down button to set the time of
regeneration.
4. Press the scroll  button again; the display will show:
Press the up  or down button to save the
program into the NOVRAM® and exit the programming level.
System Check
Cycle 1: 8 min
Regen @ 0:00
Exit
Page 11
MAINTENANCE
Page 12
ROUTINE CHECKS
Regularly the user should perform a basic check to verify if the water filter is functioning correctly, on the basis of the following control points:
1. Check settings of electronic control panel.
2. Check water composition before/after water filter.
3. Check drain line from control valve; there shouldn’t be any water flow (unless water filter is in regeneration).
4. Check water filter and surrounding area; there shouldn’t be any water leakages.
BYPASSING THE WATER FILTER
Occasionally it may be necessary to put the unit hydraulically in bypass, i.e. to isolate it from the water distribution system; f.e.:
replenishment of filter media; in case of an urgent technical problem; when it is not necessary to supply treated water to the
house/application.
WITH FACTORY BYPASS (optional)
Picture 6.a
SERVICE POSITION
= inlet valve to water filter is OPEN = outlet valve from water filter is OPEN
Picture 6.b
BYPASS POSITION
= inlet valve to water filter is CLOSED = outlet valve from water filter is CLOSED
Picture 6.c
MAINTENANCE POSITION
= inlet valve to water filter is OPEN = outlet valve from water filter is CLOSED
WITH 3-VALVE BYPASS SYSTEM (not included)
Picture 7.a
SERVICE POSITION
= bypass valve is CLOSED = inlet valve to water filter is OPEN = outlet valve from water filter is OPEN
Picture 7.b
BYPASS POSITION
= bypass valve is OPEN = inlet valve to water filter is CLOSED = outlet valve from water filter is CLOSED
Picture 7.c
MAINTENANCE POSITION
= bypass valve is OPEN = inlet valve to water filter is OPEN = outlet valve from water filter is CLOSED
FILTER MEDIA
The filter media inside this water filter consists of 'self­sacrificing' minerals, that dissolve in the acidic water to raise its pH to neutral level. In order to maintain the optimum performance of the water filter, the filter media needs to be replenished regularly. Ideally the level of filter media inside the pressure tank is kept between 1/2 and 2/3 of the pressure tank height. The frequency of replenishment depends on the water usage and pH of the incoming water, but is typically once or twice per year.
Picture 8
The user should make sure there is always a sufficient amount of filter media in the pressure tank. Therefore he should periodically check the level of filter media and refill it if necessary. The easiest way to do this is by holding a bright light against the semi-transparent pressure tank, so that the top level of the filter media inside the pressure tank becomes visible.
If the level of filter media has dropped below the minimum level, the user should refill it.
1. Put the bypass system of the water filter in 'bypass' position.
2. Manually initiate a regeneration, by pressing the scroll  button repeatedly until the display shows:
3. Leave the water filter in this position; the countdown timer will countdown to 0 sec and start a regeneration.
4. Wait until the drive motor has driven the control valve in backwash position; the display will show:
5. Wait for 10-15 sec for the pressure inside the water filter to be relieved.
6. Unscrew the cap from the media fill opening on the pressure tank.
7. Via the media fill opening, pour filter media in the pressure tank as needed to reach the desired height.
8. Clean the threaded section of the media fill opening and screw the cap back on.
9. Manually initiate a regeneration, by pressing the scroll  button repeatedly until the display shows:
10. Put the bypass system of the water filter back in 'service' position.
Regen in 10 sec
Rgn: 10 Cyc1: 8
Regen in 10 sec
MAINTENANCE
Page 13
SANITIZING THE WATER FILTER
This water filter is manufactured from premium quality material and assembled in safe conditions to assure it is clean and sanitary. If installed and serviced correctly, this water filter will not infect or contaminate your water supply. However, as in any 'device' plumbed-in in your water distribution system, a proliferation of bacteria is possible, especially in case of 'stagnant water'. Therefore this water filter will automatically rinse the filter media periodically.
If the power supply to the water filter is disconnected for a longer period of time, we recommend, when the power supply is re-established, to manually initiate a complete regeneration.
HYDRAULIC FLOW DIAGRAMS
Page 14
SERVICE BACKWASH
PURGE
TROUBLESHOOTING
Page 15
PROBLEM
CAUSE S
OLUTION
Untreated
water to
service
Open or defective bypass
Close
or replace
bypass
Water
filter in regeneration
Wait until regeneration finishes or
manually
advance regeneration to end
Valve
body and timer out of synchronisation
Synchronise valve body and timer
Low level
of
filter
media
Replenish filter media
Excessive service flow rate
Lower service flow rate
Increase filter capacity by increasing volume of filter media
Leak at riser
tube Verify that riser tube is seated correctly and is not
cracked
Water filter
fails to
start a regeneration
Faulty electrical supply
Verify electrical service (fuse, transformer,...)
Defective PCB
Replace PCB
Defective
drive motor
Replace
drive
motor
Regeneration frequency not programmed
Program regeneration frequency
Loss of water pressure
Build-up of impurities
in
pressure
tank Clean
filter media
and control valve; increase
regeneration frequency
Plugged lower and/or upper distributor
Verify that distributors are free of debris
Crushed lower and/or upper distributor
Replace distributor(s)
Control valve cycles
continuously
Defective drive motor micro switch
Replace drive motor micro switches
Defective PCB
Replace PCB
Drain line
from control
valve flows continuously
Water filter
in regeneration
Wait until regeneration finishes or
manually
advance regeneration to end
Faulty electrical supply
Verify electrical service (fuse, transformer,...)
Defective
drive motor
Replace
drive
motor
Defective micro switch
Replace micro switches
Defective PCB
Replace PCB
Valve body and timer out of synchronisation
Synchronise valve body and timer
Loss of
filter media
Lower and/or upper distributor damaged
Replace distributor(s)
Leak
between riser tube and upper distributor
Verify that riser tube is seated correctly and is not
cracked
Water filter fails to
backwash properly
Low operating pressure
Check
operating pressure; must
be higher than
2,0
bar
Insufficient water supply
Check water supply (flow rate/dynamic pressure)
Restricted drain line
Verify drain line for kinks or restrictions
Excessive b
uild-up of impurities
in
pressure
tank Clean or replace
filter media
and control valve;
increase regeneration frequency
Plugged backwash flow control
Clean or replace backwash flow control
Plugged top or bottom distributor
Verify that top and bottom distributor are clean and
slots are not clogged by iron or other impurities
Filter media is completely ‘caked’ (solid
block)
Replace filter media and reduce regeneration
interval
ELECTRICAL WIRING DIAGRAM
Page 16
= position switches
= power lead
= drive motor
= auxilliary contact (24V, max. 500mA)
= key pad
DEFAULT PARAMETER SETTINGS
Page 17
Model pHneutralizer pHneutralizerXL Filter media, quantity (Cuft - Ltr) 1 - 28 1,5 - 42 1 - 28 1,5 – 42
Interval (days) 7 7 7 7 Cycle 1: BACKWASH (min) 8 8 8 8 Cycle 2: SLOW RINSE (min) 0 0 0 0 Cycle 3: PURGE (min) 2 2 2 2 Regen @ 0:00 0:00 0:00 0:00
EXPLODED VIEW - SYSTEM
Page 18
EXPLODED VIEW - SYSTEM
Page 19
Item PN Description Remark (*)
1 PT/1040/BA/DH Pressure tank 10x40 1 Cuft
PT/1054/BA/DH Pressure tank 10x54 1,5 Cuft
2 39042 Calcite multiple of 0,5 Cuft
39043 Calcite/Corosex (70-30% mix) multiple of 0,5 Cuft 3 A1000 Gravel (4,3 kg) to be ordered per kg 4 38534 Riser tube assembly to be cut to length 5 28/298/11 Transformer 230/24V - 50 Hz, 24VA, EuroT plug 6 287/166/LS Top distributor 7 2400TF/JN/AUX Control valve 8 568/303/1 Connection kit 1” BSP male 9 38522 Drain hose to be ordered per meter
10 38521 Clamp, drain hose (2x) 11 74163 Air gap with double hose barb
(*) Recommended Spare Part
EXPLODED VIEW - TIMER HEAD
Page 20
EXPLODED VIEW - TIMER HEAD
Page 21
Item PN Description Remark (*)
1 70971 Power lead with plug 2 72263 Clamp 3 28/244/1 Plug (large) 4 71502 Screw, timer cover (3x) 5 15/222 Screw, back plate (2x) 6 70962 Back plate 7 2100/206 Drive shaft 8 15/222 Screw, drive motor assy (2x) 9 28/245/4 Cable clamp
10 71502 Strain relief, power lead 11 72261 Drive motor 12 568/227/2 Worm 13 19/48 Retaining ring 14 70965 Switch cam 15 568/386 Bracket, micro switches 16 568/310 Gear, switch cam 17 15/184/7 Locking screw, switch cam 18 15/173/12 Screw, micro switches (2x) 19 72451 Micro switch assy 20 71679 Cable set, drive motor
21 15/102 Screw, PCB (2x) 22 72703 Printed Circuit Board 23 72614 Timer cover assembly
(*) Recommended Spare Part
EXPLODED VIEW - VALVE BODY
Page 22
EXPLODED VIEW - VALVE BODY
Page 23
Item PN Description Remark (*)
1 21/83 Drain connection 2 568/271/N Backwash flow control N (22,7 Ltr/min) 3 72678 Bolt, valve cover (6x) 4 568/254/3 Valve cover 5 185/154/1 O-ring, valve cover 6 186/112 O-ring, Teflon 7 72327 Washer, PE 8 568/260 Worm gear
9 568/259 Rotor cam 10 185/041/1 O-ring, rotor 11 568/345/2 Rotor plate 12 568/256 Seal disk 13 568/383 Insert plate 14 568/384 Gasket 15 413/62 Spring, float valve 16 568/270/4 Float valve 17 568/274/5 Injector (green) 18 186/118 O-ring, plug (small) 19 541/273 Plug (small) 20 541/254 Spring clip, plug (small) 21 570/251 Gasket, riser 22 568/334 Riser insert 23 185/214/1 O-ring, riser tube 24 185/337/1 O-ring, tank 25 541/232 Adapter ring 26 15/207/12 Screw, adapter ring (2x) 27 72772 Packing gland nut (plastic) 28 185/211/1 O-ring, packing gland nut 29 186/115 O-ring, worm drive shaft (2x) 30 568/208/2 Worm drive shaft 31 14/43 Washer, worm drive shaft 32 185/208/1 O-ring, plug (large) 33 21/72/3 Plug (large) 34 72800 Valve body
A RK/568/259/2 Repair kit rotor
B RK/75154 Repair kit packing gland nut
(*) Recommended Spare Part
TECHNICAL DATA
Page 24
Technical specifications:
Model pHneutralizer pHneutralizerXL Filter media, quantity (Cuft - Ltr) 1 - 28 1,5 - 42 1 - 28 1,5 – 42
Operating pressure min/max (bar) 2,0/8,3 Operating temperature min/max (°C) 4/38 Electrical connection (V/Hz) 230/50
(1)
Max. power consumption (VA) 12 Hydraulic connection inlet/outlet 1” BSP Male
(1) Supplied with 230/24V-50Hz transformer.
Performances @ 3 bar operating pressure:
Model pHneutralizer pHneutralizerXL Filter media, quantity (Cuft - Ltr) 1 - 28 1,5 - 42 1 - 28 1,5 – 42
Recommended max. service flow (m3/hr)
(2)
1,4 1,6 1,4 1,6
Nominal backwash flow = flow to drain (Ltr/min) 23 Rinse water usage per regeneration (Ltr) 227
(2) = continuous service flow rates; higher (up to x2) short-period peak flow rates are possible.
Dimensions and weights:
Model pHneutralizer pHneutralizerXL Filter media, quantity (Cuft - Ltr) 1 - 28 1,5 - 42 1 - 28 1,5 – 42
Width (mm) 268 268 268 268 Height (mm) 1.191 ±10 1.556 ±10 1.191 ±10 1.556 ±10 Depth (mm) 290 290 290 290 Depth, incl. factory bypass (mm) 371 371 371 371 Height inlet/outlet (mm) 1.053 1.418 1.053 1.418 Weight (kg) 51,5 74,0 49,5 71,0
© 2012 Aquion, Inc. PP-Neutralizer-Rev2014.03
r
1.a
r
1.b
2.a
2.b
3.a
3.b
© 2012 Aquion, Inc. PP-Neutralizer-Rev2014.03
r
4.a
r
4.b
5
r
6.a
r
6.b
© 2012 Aquion, Inc. PP-Neutralizer-Rev2014.03
r
6.c
7.a
7.b
r
7.c
© 2012 Aquion, Inc. PP-Neutralizer-Rev2014.03
r
8
AQUION, INC.
Lammerdries-Oost 30c
B-2250 Olen
Belgium
+32 (0) 14-28.51.71 +32 (0) 14-28.51.70
RPR/RPM Turnhout
BWT/TVA/VAT BE 0882.738.206
infobelgium@eriewatertreatment.com
www.eriewatertreatment.com