The PBL 386 11/2 Subscriber Line Interface Circuit (SLIC) is a 90 V bipolar inte­grated circuit for use in DAML, FITL and other telecommunications equipment. The PBL 386 11/2 has been optimized for low total line interface cost and a high degree of flexibility in different applications.
The PBL 386 11/2 emulates a transformer equivalent dc-feed, programmable between 2x25 and 2x900 Ω, with short loop current limiting adjustable to max 65 mA.
Two- to four-wire and four- to two-wire voice frequency (vf) signal conversion is accomplished by the SLIC in conjunction with either a conventional CODEC/filter or with a programmable CODEC/filter, e.g. SLAC, SiCoFi, Combo II. The programmable line terminating impedance could be complex or real to fit every market.
Longitudinal line voltages are suppressed by a feedback loop in the SLIC and the longitudinal balance specifications meet Bellcore TR909 requirements.
The PBL 386 11/2 package are 28-pin PLCC and 28 pin SSOP.
Figure 1. Block diagram.
February 2000
PBL 386 11/2
Subscriber Line
Interface Circuit
Key Features
• Selectable overhead voltage principle – All adaptive: The overhead voltage follows 0.6 V
Peak
< signals < 5 V
Peak
. – Semi adaptive: The overhead voltage follows 2.5 V
Peak
< signals <
5 V
Peak
.
• Metering 1.6 V
rms
• High and low battery with automatic switching
• Battery supply as low as -10V
• Only +5V in addition to GND and battery (VEE optional)
• 35 mW on-hook power dissipation in active state
• Long loop battery feed tracks V
Bat
for
maximum line voltage
• 44V open loop voltage @ -48V battery feed
• Constant loop voltage for line leakage <5 mA
• On-hook transmission
• Full longitudinal current capability during on-hook
• Programmable loop & ring-trip detector threshold
• Ground key detector
• Analog temperature guard
• Silent polarity reversal
• Integrated Ring Relay Driver
28-pin plastic PLCC and 28-pin SSOP
1
VF Signal
Transmission
Off-hook Detector
Line Feed Controller
and
Longitudinal
Signal
Suppression
Ring Trip
Two-wire Interface
Input
Decoder and
Control
C1
C2
DET
REF
LP
VTX
RSN
DT
DR
TIPX
HP
RINGX
VCC
VEE
VBAT2
VBAT
AGND
C3
BGND
Comparator
Ground Key
Detector
Ring Relay
Driver
RRLY
PLD
PLC
PSGTS
AOV
VEE
PBL
386 11/2
PBL 386 11/2
PBL 386 11/2
2
Maximum Ratings
Parameter Symbol Min Max Unit
Temperature, Humidity
Storage temperature range T
Stg
-55 +150 °C
Operating temperature range T
Amb
-40 +110 °C
Operating junction temperature range, Note 1 T
J
-40 +140 °C
Power supply, 0°C T
Amb
+70°C
V
CC
with respect to AGND V
CC
-0.4 6.5 V
V
EE
with respect to AGND V
EE
V
Bat
0.4 V
V
Bat2
with respect to A/BGND V
Bat2
V
Bat
0.4 V
V
Bat
with respect to BGND, continuous V
Bat
-75 0.4 V
V
Bat2
with respect to BGND, 10 ms V
Bat2
-80 0.4 V
Power dissipation
Continuous power dissipation at T
Amb
+70 °CP
D
1.5 W
Ground
Voltage between AGND and BGND V
G
-5 VCC V
Relay Driver
Ring relay supply voltage BGND +13 V Ring relay current 75 mA
Ring trip comparator
Input voltage V
DT
, V
DR
V
Bat
V
CC
V
Input current I
DT
, I
DR
-5 5 mA
Digital inputs, outputs (C1, C2, C3, DET) Input voltage V
ID
-0.4 V
CC
V
Output voltage (DET not active) V
OD
-0.4 V
CC
V
Output current (DET) I
OD
30 mA
TIPX and RINGX terminals, 0°C < T
Amb
< +70°C, V
Bat
= -50 V
TIPX or RINGX current I
TIPX
, I
RINGX
-110 +110 mA
TIPX or RINGX voltage, continuous (referenced to AGND), Note 2 V
TA
, V
RA
V
Bat
2V
TIPX or RINGX, pulse < 10 ms, t
Rep
> 10 s, Note 2 VTA, V
RA
V
Bat
- 20 5 V
TIPX or RINGX, pulse < 1 µs, t
Rep
> 10 s, Note 2 VTA, V
RA
V
Bat
- 40 10 V
TIP or RING, pulse < 250 ns, t
Rep
> 10 s, Note 3 VTA, V
RA
V
Bat
- 70 15 V
Recommended Operating Condition
Parameter Symbol Min Max Unit
Ambient temperature T
Amb
0 +70 °C
V
CC
with respect to AGND V
CC
4.75 5.25 V
V
EE
with respect to AGND V
EE
V
Bat
-4.75 V
V
Bat
with respect to BGND V
Bat
-58 -10 V
V
Bat2
with respect to BGND V
Bat2
V
Bat
-10 V
Notes
1. The circuit includes thermal protection. Operation above max. junction temperature may degrade device reliability.
2. A diode in series with the VBat input increases the permitted continuous voltage and pulse < 10 ms to -85 V. A pulse ≤1µs is increased to the greater of |-70V| and |VBat -40V|.
3. R
F1
and RF2 20 is also required. Pulse is supplied to TIP and RING outside RF1 and RF2.
PBL 386 11/2
3
Figure 2. Overload level, V
TRO
, two-wire
port
1
<< R
L
, RL= 600
ωC R
T
= 120 kΩ, RRX = 120 k
Electrical Characteristics
0 °C T
Amb
+70 °C, VCC = +5V ±5 %, VEE = -5V ± 5%, V
Bat
= -58V to -40V, RLC=18.7k, (IL = 27 mA), ZL = 600 , RLD = 50 kΩ,
R
F1
, RF2 = 0 , R
Ref
= 15k, CHP = 68nF, CLP=0.33 µF, RT = 120 k, RSG = 24 k, RRX = 120 k, AOV and V
Bat2
-pin not connected, unless otherwise specified. Current definition: current is positive if flowing into a pin. Active state includes active normal and active reverse states unless otherwise specified.
Ref
Parameter fig Conditions Min Typ Max Unit
Two-wire port
Overload level, V
TRO
2 Active state
Off-Hook, I
LDC
10 mA 1% THD, Note 1 2.5 V
Peak
On-Hook, I
LDC
5 mA 1.4 V
Peak
Metering I
LDC
10 mA ZLM = 200 Ω, f = 16 kHz 2.3 V
Peak
Input impedance, Z
TR
Note 2 ZT/200
Longitudinal impedance, Z
LoT
, Z
LoR
0 < f < 100 Hz 20 35 /wire
Longitudinal current limit, I
LoT
, I
LoR
active state 12 mA
rms
/wire
Longitudinal to metallic balance, B
LM
IEEE standard 455-1985, ZTRX = 736
0.2 kHz < f < 1.0 kHz 53 70 dB
1.0 kHz < f < 3.4 kHz 53 70 dB
Longitudinal to metallic balance, B
LME
3 active state
E
Lo
B
LME
= 20 • Log 0.2 kHz f 1.0 kHz 53 70 dB
V
TR
1.0 kHz < f < 3.4 kHz 53 70 dB
Longitudinal to four-wire balance, B
LFE
3 active state
E
Lo
B
LFE
= 20 • Log 0.2 kHz f 1.0 kHz 59 70 dB
V
TX
1.0 kHz < f < 3.4 kHz 59 70 dB
Metallic to longitudinal balance, B
MLE
4 active state
VTR
B
MLE
= 20 • Log ;ERX = 0 0.2 kHz < f < 3.4 kHz 40 58 dB
V
Lo
Figure 3. Longitudinal to metallic (B
LME
)
and Longitudinal to four-wire (B
LFE
)
balance
1 << 150 , R
LR
= RLT = RL /2= 300
ωC R
T
= 120 kΩ, RRX = 120 k
PBL 386 11/2
TIPX
RINGX
RSN
VTX
R
T
R
RX
E
RX
R
L
V
TRO
I
LDC
C
PBL 386 11/2
TIPX
RINGX RSN
VTX
R
T
R
RX
V
TX
R
LT
C
V
TR
R
LR
E
Lo
PBL 386 11/2
4
Parameter fig Conditions Min Typ Max Unit
Four-wire to longitudinal balance, B
FLE
4 active state
E
RX
B
FLE
= 20 • Log
V
Lo
0.2 kHz < f < 3.4 kHz 40 58 dB
Two-wire return loss, r |Z
TR
+ ZL|
r = 20 • Log
|Z
TR
- ZL|
0.2 kHz < f < 0.5 kHz 25 dB
0.5 kHz < f < 1.0 kHz 27 dB
1.0 kHz < f < 3.4 kHz, Note 3 23 dB
TIPX idle voltage, V
Ti
active normal, IL = 0 - 1.2 V
RINGX idle voltage, V
Ri
active normal, IL = 0 V
Bat
+ 2.4 V
|V
TR
| active, IL = 0 |V
Bat
+4.5| |V
Bat
+ 3.6| V
Four-wire transmit port (VTX) Overload level, V
TXO
5
Off-hook, I
L
10mA Load impedance > 20 k, 1.25 V
Peak
On-hook, IL ≤ 5mA 1% THD, Note 4 0.7 V
Peak
Output offset voltage, ∆V
TX
-60 60 mV
Output impedance, z
TX
0.2 kHz < f < 3.4 kHz 5 20
Four-wire receive port (RSN) Receive summing node (RSN) dc voltage I
RSN
= 0 mA GND +25 mV Receive summing node (RSN) impedance 0.2 kHz < f < 3.4 kHz 10 50 Receive summing node (RSN) 0.3 kHz < f < 3.4 kHz current (I
RSN
) to metallic loop current (IL) 400 ratio
gain,α
RSN
Frequency response
Two-wire to four-wire, g
2-4
6 relative to 0 dBm, 1.0 kHz. ERX = 0 V
0.3 kHz < f < 3.4 kHz -0.15 0.15 dB f = 8.0 kHz, 12 kHz, 16 kHz -0.5 -0.1 0 dB
Figure 4. Metallic to longitudinal and four-wire to longitudinal balance
1 << 150 , R
LT
= RLR = RL /2 =300
ωC RT = 120 kΩ, RRX = 120 k
Figure 5. Overload level, V
TXO
, four-wire
transmit port
1 << R
L
, RL = 600
ωC R
T
= 120 kΩ, RRX = 120 k
Ref
PBL 386 11/2
TIPX
RINGX RSN
VTX
R
T
R
RX
E
RX
R
LT
C
V
TR
R
LR
V
Lo
PBL 386 11/2
TIPX
RINGX RSN
VTX
R
T
R
RX
R
L
I
LDC
C
E
L
V
TXO
PBL 386 11/2
5
Four-wire to two-wire, g
4-2
6 relative to 0 dBm, 1.0 kHz. EL = 0 V
0.3 kHz < f < 3.4 kHz -0.15 0.15 dB f = 8 kHz, 12 kHz, -1.0 -0.2 0 dB 16 kHz -1.0 -0.3 0 dB
Four-wire to four-wire, g
4-4
6 relative to 0 dBm, 1.0 kHz. EL = 0 V
0.3 kHz < f < 3.4 kHz -0.15 0.15 dB
Insertion loss
Two-wire to four-wire, G
2-4
6 0 dBm, 1.0 kHz, Note 5
V
TX
G
2-4
= 20 • Log ,ERX = 0
V
TR
-6.22 -6.02 -5.82 dB
Four-wire to two-wire, G
4-2
6 0 dBm, 1.0 kHz, Notes 5, 6
V
TR
G
4-2
= 20 • Log ,EG = 0
E
RX
-0.2 0.2 dB
Gain tracking
Two-wire to four-wire R
LDC
2k 6 Ref. -10 dBm, 1.0 kHz, Note 7
-40 dBm to +3 dBm -0.1 0.1 dB
-55 dBm to -40 dBm -0.2 0.2 dB
Four-wire to two-wire R
LDC
2k 6 Ref. -10 dBm, 1.0 kHz, Note 7
-40 dBm to +3 dBm -0.1 0.1 dB
-55 dBm to -40 dBm -0.2 0.2 dB
Noise
Idle channel noise at two-wire C-message weighting 7 12 dBrnC (TIPX-RINGX) Psophometrical weighting -85 -78 dBmp
Note 8
Harmonic distortion
Two-wire to four-wire 6 0 dBm, 1.0 kHz test signal -50 dB Four-wire to two-wire 0.3 kHz < f < 3.4 kHz -50 dB
Battery feed characteristics
Constant loop current, I
LConst
13 I
LProg
=
500
R
LC
18 < I
LProg
< 65 mA 0.92 I
LProgILProg
1.08 I
LProg
mA
Ref
Parameter fig Conditions Min Typ Max Unit
Figure 6. Frequency response, insertion loss, gain tracking.
1 << R
L
, RL = 600
ωC RT = 120 kΩ, RRX = 120 k
PBL 386 11/2
TIPX
RINGX RSN
VTX
R
T
R
RX
E
RX
R
L
V
TR
I
LDC
C
E
L
V
TX
PBL 386 11/2
6
Loop current detector
Programmable threshold, I
DET
I
LTh
=
500 0.9•I
LThILTh
1.1•I
LTh
mA
I
LTh
> 10 mA R
LD
Ground key detector
Ground key detector threshold I
LTIPX
and I
LRINGX
current difference to trigger ground key det. 11 15 19 mA
Ring trip comparator
Offset voltage, ∆V
DTDR
Source resistance, RS = 0 -20 0 20 mV
Input bias current, I
B
IB = (IDT + IDR)/2 -50 -20 nA
Input common mode range, V
DT
, V
DR
V
Bat
+1 -1 V
Ring relay driver
Saturation voltage, V
OL
IOL = 50 mA 0.2 0.5 V
Off state leakage current, I
Lk
V
OH
= 12 V 100 µA
Digital inputs (C1, C2, C3) Input low voltage, V
IL
0 0.5 V
Input high voltage, V
IH
2.5 V
CC
V
Input low current, |I
IL
|V
IL
= 0.5 200 µA
Input high current, I
IH
VIH = 2.5 V 200 µA
Detector output (DET) Output low voltage, V
OL
IOL = 1 mA 0.1 0.6 V
Internal pull-up resistor to V
CC
10 k
Power dissipation (V
Bat
= -48V, V
Bat2
= -32V)
P
1
Open circuit state, C1, C2, C3 = 0, 0, 0 10 14 mW
P
2
@ VEE=-5V Active state, C1, C2, C3 = 0, 1, 0 35 42 mW
P
3
@ VEE=-48V Longitudinal current = 0 mA, IL = 0 mA 39 46 mW
P
4
@ VEE = -5V RL = 300Ω (off-hook) 710 mW
P
5
@ VEE = -5V RL = 800Ω (off-hook) 340 mW
Power supply currents (V
Bat
= -48V)
V
CC
current, I
CC
Open circuit state 0.8 mA
V
EE
current, I
EE
C1, C2, C3 = 0, 0, 0 -0.2 -0.1 mA
V
Bat
current, I
Bat
-0.2 -0.1 mA
V
CC
current, I
CC
Active state 2.1 3.5 mA
V
EE
current, I
EE
C1, C2, C3 = 0, 1, 0 0.1 0.3 mA
V
Bat
current, I
Bat
, On-hook Long Current = 0 mA, IL = 0 mA -0.8 -0.5 mA
Power supply rejection ratios
VCC to 2- or 4-wire port Active State 30 45 dB V
EE
to 2- or 4-wire port C1, C2, C3 = 0, 1, 0 28.5 55 dB
V
Bat
to 2- or 4-wire port f = 1 kHz, Vn = 100mV 40 50 dB
V
Bat2
to 2- or 4-wire port 28.5 60 dB
Temperature guard
Junction threshold temperature, T
JG
140 °C
Parameter fig Conditions Min Typ Max Unit