INSTRUCTION SHEET
CADDY® EZ RISER
MODEL #510+
MODEL #512**
MODEL #520
Model #520 Size Range: 1/2” – 8”
Model #512(CQ) Size Range: 1”–3”, 4”-6”**
STEP 1.
STEP 2.
STEP 3.
WARNING:
1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative.
2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3. All instructions must be completely followed to ensure proper and safe installation and performance.
4. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury, and death.
6. All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described here in and are NEVER to be used for any other purpose. NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for: a. Conformance to all governing codes. b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer. c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are registered trademarks of ERICO International Corporation
TECHNICAL SUPPORT: CFS306_L 1 of 2 2008 ERICO International Corporation
www.erico.com
THIS PRODUCT PROVIDES SUPPORT FOR VERTICAL STEEL PIPE RISERS. INSTALL IN ACCORDANCE WITH ANSI/MSS-SP-69.
CLAMP IS FITTED FOR STEEL PIPE AND SHOULD BE INSTALLED BELOW A COUPLING OR SHEAR LUG, WITH BOLTS TORQUED TO *RECOMMENDED VALUE.
+
SIZES 2” THRU 8” ARE cULus LISTED. CONTROL NUMBER 507P
**MODEL #512(CQ), SIZES 1” THRU 3” AND 4” THRU 6” ARE cULus LISTED. CONTROL NUMBER 507P
STEP 1: LOOSEN BOLTS, AND SEPARATE TWO HALVES OF THE RISER. (NOTE: DO NOT REMOVE BOLTS, JUST LOOSEN NUTS).
STEP 2: PLACE EACH HALF OF THE RISER CLAMP AROUND THE PIPE, AS SHOWN. (NOTE: INSTALL THE SLOTTED HALF WITH OPEN SIDE OF SLOTS FACING UP AS SHOWN).
FOR
NOMINAL
PIPE SIZE
1/2" 255 3/4" 255
1" 255 1-1/4" 255 1-1/2" 255
2" 255 2-1/2" 390
3" 530
MAX.
RECOM.
LOAD LBS.
3-1/2" 670
STEP 3: SLIDE THE HALF WITH THE BOLTS INTO THE HALF WITH THE SLOTS, AS SHOWN. THEN LET THE RISER CLAMP SLIDE DOWN THE PIPE UNTIL IT RESTS ON THE FLOOR.
4" 810
5" 1160
6" 1570
8" 2500
10" 2500
STEP 4:
12" 2700
TIGHTEN (TORQUE) THE BOLTS.
**+ cULus IS A REGISTERED TRADEMARK OF UNDERWRITERS LABORATORIES.
APPLY FORCE TO BOLT WITH FINGER
RECOMMENDED TORQUE
Models 510 and 520 3/8-16 Bolt 19 ft. lbs 1/2-13 Bolt 50 ft. lbs. 5/8-11 Bolt 75 ft. lbs.
Model 512
3/8-16 Bolt 30 ft. lbs
STEP 4.
1/2-13 Bolt 50 ft. lbs.
INSTRUCTION SHEET
®
EZ RISER
CADDY
MODEL #511
STEP 1.
STEP 2.
THIS PRODUCT PROVIDES SUPPORT FOR VERTICAL COPPER TUBING RISERS. INSTALL IN ACCORDANCE WITH ANSI/MSS-SP-69. CLAMP IS FITTED FOR COPPER TUBING AND SHOULD BE INSTALLED BELOW A
COUPLING OR FITTING ON THE TUBING, WITH BOLTS TORQUED TO RECOMMENDED VALUE.
COPPER PLATING IS FOR IDENTIFICATION PURPOSES ONLY.
STEP 1: LOOSEN BOLTS, AND SEPARATE TWO HALVES OF THE RISER. (NOTE: DO NOT REMOVE BOLTS, JUST LOOSEN NUTS).
STEP 2: PLACE EACH HALF OF THE RISER CLAMP AROUND THE PIPE, AS SHOWN. (NOTE: INSTALL THE SLOTTED HALF WITH OPEN SIDE OF SLOTS FACING UP AS SHOWN).
STEP 3: SLIDE THE HALF WITH THE BOLTS INTO THE HALF WITH THE SLOTS, AS SHOWN. THEN LET THE RISER CLAMP SLIDE DOWN THE PIPE UNTIL IT RESTS ON THE FLOOR.
STEP 4: TIGHTEN (TORQUE) THE BOLTS.
FOR
NOMINAL
PIPE SIZE
RECOM.
LOAD LBS. 1/2" 75 3/4" 75
1" 120 1-1/4" 150 1-1/2" 150
2" 150 2-1/2" 300
3" 300
4" 300
5" 500
6" 600
MAX.
APPLY FORCE TO BOLT WITH FINGER
3/8-16 Bolt 19 ft. lbs.
Model 511
1/2-13 Bolt 50 ft. lbs. 5/8-11 Bolt 75 ft. lbs.
RECOMMENDED TORQUE
STEP 3.
WARNING:
1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative.
2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3. All instructions must be completely followed to ensure proper and safe installation and performance.
4. Improper installation, misuse, misapplication or other failure to completely follow ERICO’s instructions and warnings may cause product malfunction, property damage, serious bodily injury, and death.
6. All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described here in and are NEVER to be used for any other purpose. NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for: a. Conformance to all governing codes. b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer. c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
STEP 4.