Ergotron APB-1112G, APB-1112H, LifeKinnex, APB-1112, APB-1112B User Manual

...
1 of 15
888-83-080-G-00 rev. B • 01/19
www.ergotron.com |
USA: 1-800-888-8458
|
Europe: +31 (0)33-45 45 600
|
|
Japan: japansupport@ergotron.com
English, Español, Français, Deutsch, Nederlands, Italiano, Svenska, 日本語, 汉语
Power Module
User's Guide
English
For the latest User Installation Guide please visit: www.ergotron.com
The LiFeKinnex Power Module is intended to provide uninterrupted AC power to support AC powered computer equipment. The Power Module is not intended to power medical products or devices. Please review this manual before installing your equipment to learn how to use this product safely. This product is a certifi ed medical power module according to IEC/EN 60601-1, as class I equipment. This power module is intended for use with IEC 60601-1 certifi ed equipment in the patient Environment and IEC 60601-1 and IEC 60950-1 certifi ed equipment outside of patient environment. AC input: 100-240V~ 50/60-Hz. Max amps: 4.8 - 2.1A. Manufactured for Ergotron by Green Cubes Technology www.greencubestech.com Patents Ergotron.com/patents Battery Sold Separately.
2 of 15
888-83-080-G-00 rev. B • 01/19
CAUTION: To avoid the potential to pinch cables it is important to follow the cable routing instructions in this manual. Failure to follow these instructions may result in equipment damage or personal injury.
Equipment Electrical Safety
WARNING: Failure to observe the following Electrical Safety notices can result in fi re or death by electric shock.
Electrical cables can be hazardous. Misuse can result in fi re or death by electrical shock.
• Inspect power cables thoroughly before each use.
• Do not use cables that are damaged.
• Insert the plug completely into the outlet.
• Grasp the plug to remove from the outlet.
• Do not unplug by pulling on the cable.
• Do not use excessive force to make connections.
• Do not plug the cable into an extension cable.
• Do not remove, bend or modify any metal prongs or pins of cable.
• Do not drive, drag or place objects over the cable.
• Do not walk on the cable.
• Avoid overheating.
• Do not run cable through doorways, holes in ceilings, walls or fl oors.
Keep away from water.
• Do not use it when wet.
• Do not place in close proximity to fl ammable liquids or gases.
WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is
necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
WARNING: Use of accessories, transducers and cables other than those specifi ed or provided by the manufacturer of this equipment could result in increased
electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
CAUTION: The power disconnect for this equipment is the AC power cable. Do not use this unit outdoors. Never unplug this product from the outlet when your hands are wet. Any modifi cations made to this device that are not approved, may void the authority granted to the user by the FCC to operate this equipment. Ensure the product is connected to an outlet having the same confi guration as the plug. No adapter should be used with this product.
Ergotron does not accept any liability for damage if the unit is misused, incorrectly operated or inadequately repaired. Under these circumstances the warranty will be void.
DANGER! Electrical cables can be hazardous. Misuse can result in fi re or death by electrical shock.
These symbols alert users of a safety condition that demands attention. All users should be able to recognize and understand the signifi cance of the following Safety Hazards if encountered on the product or within the documentation. Children who are not able to recognize and respond appropriately to Safety Alerts should not use this product without adult supervision!
Hazard Symbols Review
Safety
Symbol Signal Word Level of Hazard
INSTRUCTIONS
Refer to instruction manual/booklet. Follow instructions for use.
CAUTION
A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING
A WARNING indicates either potential for property damage, personal injury, or death.
DANGER
A DANGER indicates a hazardous situation that, if not avoided, will result in death or serious injury.
3 of 15
888-83-080-G-00 rev. B • 01/19
Do not attempt to connect the power modules in serial or parallel with any other power modules. This system was not designed to serve this purpose. This power module shall be installed by qualifi ed personnel only. The system shall be always installed in the vertical direction as shown in the picture on cover page.
WARNING: DO NOT charge battery with any other charger.
WARNING: Battery contains magnets. Magnets may be harmful to persons with implanted medical devices. Keep battery at least 6" (152 mm) away from any
implanted medical devices.
WARNING: Keep battery and Power Module cool or at room temperature Operating Temperature: 10°C to 40°C (50°F to 113°F) Storage Temperature: -20°C to 45°C (-4°F to 113°F)
WARNING: Never attempt to open or service the battery.
WARNING: Never attempt to short circuit the battery or the Power Module intentionally.
WARNING: DO NOT drop, puncture or crush battery or expose to water.
WARNING: DO NOT dispose battery in fi re in any circumstances. Keep battery pack away from any hot source.
WARNING: DO NOT use battery if physical damage is evident.
WARNING: To avoid risk of electric shock, do not expose electrical component to water, cleaning solution or other potentially corrosive liquids or substances.
WARNING: To avoid risk of electric shock, this equipment must be connected to AC mains with protective earth.
WARNING: In rare case, if the power module and battery protection features fail, the battery may become overcharged and in some instances, it may become extremely hot, possibly melting the plastics and releasing smoke. If a battery begins to smoke or melts:
Unplug the cart, or if possible disconnect the battery from Power Module immediately. Move the cart to a well-ventilated area. Use a Carbon Dioxide, Dry Chemical, or appropriate foam fi re extinguisher to spray the hot battery. If a fi re extinguisher is not available, use copious amounts of
water, or cover the battery with sand. Exposure to vapor released from the battery is irritating to the eyes, skin, mucous membranes, and respiratory tract. This may cause nausea, dizziness, and headache. In case of direct contact to the battery's electrolyte: Immediately fl ush eyes with water for at least 15 minutes. Thoroughly rinse hands and other aff ected areas with water. Promptly remove and wash any contaminated clothing. In all cases, seek immediate medical attention!
Placement: Do not expose the Power Module to direct sunlight or other heat source. Ensure the operating environment is well ventilated to allow adequate dissipation of heat. Ensure the Power Module surrounding area is clean and free from moisture. Do not put heavy objects on the Power Module. The socket outlet should be easily accessible and should be installed near the equipment.
AC Inlet power cords: AC mains plug shall have the protective earth pin. By connecting the plug to the Power Module, it shall have not more than 200mΩ to any part of the system metal case. The connector shall be an IEC 60320 compliant C13 plug. The power cords shall be IEC 60227 or HO5VV compliances. AC Outlet power cords: The connector shall be an IEC 60320 compliant C14 inlet. The power cords shall be IEC 60227 or HO5VV compliant.
Safety
4 of 15
888-83-080-G-00 rev. B • 01/19
Features & Specifi cations
EMC levels are evaluated according to IEC60601-1-2/EN60601-1-2. This power module was not designed to be water proof, therefore, its classifi ed as IPX0 and also not evaluated as AP/APG equipment.
Certifi cation: UL 60601-1 Safety of Medical Electrical Equipment CAN/CSA C22.2 No. 601.1 IEC 60601-1 ICES-003 Issue 5, Class A FCC Part 15 Class A RoHS and REACH compliant material used.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation. CAN ICES3(A)/NMB-3(A). Changes or modifi cations not expressly approved by the Ergotron could void the user's authority to operate the equipment. Intended for institutional use. Note: The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals (CISPR 11 class A). If it is used in residential environment (For which CISPR 11 class B is normally required) this equipment might not off er adequate protection to radio-frequency communication services. Mitigation measures, such as relocating or re-orienting the equipment may be necessary.
Regulatory Model Number APB-1112G APB-1112H APB-1112B APB-1112 APB-1112C APB-1112D APB-1112F
Part Number 916-501-00 916-338-00 916-499-00 916-334-00 916-337-00 916-336-00 916-335-00
Input Voltage Range 100~ 240Vac
Frequency 50 / 60 Hz
Power Factor PF>0.94/230Vac PF>0,98/115Vac
Output Voltage Range (+/-3%) 100Vac 100Vac 120Vac 120Vac 127Vac 220Vac 230Vac
Frequency (+/-1 Hz) 50 60 50 60 60 60 50
Wave form Pure Sine Wave
Output Power (Continuous) 150VA
Output Power (Maximum) 180VA average up to 5 minutes
Output Power (Peak) 200VA average up to 1 second
Swappable
Battery
Lithium Iron
Phosphate
245Wh
916-333-00
Nominal Voltage 12.8V
Nominal Capacity 19.2Ah/245Wh
Charging Voltage 14.4V
Maximum Charging Current 15A
Maximum Discharge Current 21A
Approximate Weight 6.2lbs
Communication SMBUS
Operating Ambient Temperature 10° to 40°C
Transportation Temperature/Humidity -20° to +70°C/ 5% to 95%
Storage Temperature/Humidity -20° to +45°C/ 5% to 95%
Ambient Relative Humidity 20 to 90% Non-Condensing
Operating Altitude 4000 meters
5 of 15
888-83-080-G-00 rev. B • 01/19
AB CD
1
2
3
4
mm
1x
1x
1x
4x
1x
1x
1x
1x
1x
1x
2x
1x
M3 x 8mm
5x
M5 x 10mm
4x
M4 x 8mm
1x
Battery Sold Separately.
Lithium Iron Phosphate 245Wh, 916-333-00
Tools Needed
Components
Power Module
Display
Cable Wrap
Cable Tie
Display Base
Hex Wrench
Bottom Cover
Power Strip
Screw
Back Cover
Coiled Cord
Screw
Mounting Bracket
T-Slot Bracket
Screw
Loading...