Read all instructions before using your adjustable base. Save these instructions.
To reduce the risk of shock, burns, fire or injury:
• Always unplug the base from the electrical outlet before servicing any part of the base. To reduce
risk of electric shock, unplug the base before cleaning. To safely disconnect, ensure the base is in a
flat position with all motors o, and unplug from power source.
• Keep the power cord away from heated surfaces. Never operate the base when the air openings are
blocked. Keep air openings free of lint, hair and the like. Do not drop or insert any object into any
opening.
• Discontinue use of the bed base and contact a qualified service center if: it has a damaged cord or
plug, if it is not working properly, or it has been dropped into water.
• Only use this bed base for its intended use as described in this manual. Do not use accessories/
attachments that are not recommended by the manufacturer.
• Close supervision is required when the bed base is used by or near children, convalescents or
disabled persons.
Outlet Safety:
For optimal safety and operation, plug bed base into a
surge protector (not included).
The bed base should only be plugged directly into a
wall outlet or surge protector (strongly recommended).
Improper connection of the equipment can result in the
risk of electrical shock, electrical fire or faulty operation
of this bed base. If the plug does not fit your outlet,
contact a qualified electrician to install a suitable outlet.
Unauthorized modification or failure to use a wall outlet
or surge protector could void the electrical portion of
your warranty.
Warranty Warning:
Do not open or tamper with control box, motors, or
remote (with the exception of battery compartments).
The warranty will be void if the internal workings of
these components are tampered with.
For complete warranty information visit www.
ergomotion.com or refer to the warranty card included
with the base.
In-Home Use and Hospital Disclaimer:
Ergomotion adjustable bed bases are designed solely for
in-home use. This base was not designed as a hospital
bed and is not designed to meet hospital standards.
Do not use this base with TENT TYPE oxygen therapy
equipment or near explosive gases.
Pacemaker Notice:
It is possible that some pacemakers may falsely interpret
the optional massage feature vibrations as movement/
exercise. This is a common occurrence with any product
that creates a vibrating movement and may not aect the
pacemaker. Please consult your physician before using the
massage feature.
Pets and Small Children:
Immediately dispose of all packing materials as it may
pose a smothering risk to small children and pets. To
avoid injury, it is not advised to allow children and small
pets to play on or under the bed. Children should not
operate the bed base without adult supervision.
Safety Features:
Casters (optional leg accessory) are equipped with
locking wheels to prevent unwanted movement. Even
when locked and unable to roll, it is possible for the
casters to slide. Free release head and foot motors are
designed to lower the mattress by retracting only with
gravity, never pulling downwards, which minimizes pinch
points.
Product Ratings:
The lift motors are not designed to operate continuously
for more than [2] minutes in an [18] minute time
period or approximately 10% duty cycle. Attempting
to circumvent or exceed this rating will shorten the life
expectancy of the product and may void the warranty.
1
safety precautions and usage statements
Weight Limits:
This product is not rated to support weights exceeding
650 for the 40+ or 850 pounds for the 330/390. This
product is not rated to support weights in excess of
650/850 pounds inclusive of the mattress and bedding.
The base will structurally support this weight, provided it
is evenly distributed across the bed base. The adjustable
base is not designed to support or lift this amount in
the head or foot sections alone. Exceeding this weight
restriction could damage the bed and/or cause injury
and will void the warranty
Acoustics:
The massage function will emit a noticeable tone
during operation. As the massage intensity level is
increased, the tone will intensify. The volume of this
tone is directly related to the location environment.
For example, when demonstrated in a show room,
the surrounding environmental noise will cover some
of the massage noise. However, when installed in a
home setting with wooden floors, carpeted or not, the
massage volume will be more noticeable. In normal
base operation, the wheels which allow the bed to
maintain its distance from the wall, will make contact
with the steel platform supports of the base creating a
contact noise. When entering, exiting or shifting weight
on the base, this contact noise may be audible as the
wheels make contact. This is normal.
Fabric Care:
To prolong the life of your fabric, protect from direct
sunlight whenever possible. For spot cleaning, wipe area
with a light damp sponge or vacuum with a soft brush
attachment to remove particles. Keep at a minimum of
30cm (12 inches) away from direct heat sources.
For deeper cleaning, blot liquid spills with a clean dry
cloth. Wipe with a clean cloth dampened with warm
water. Do not wet excessively. A soft bristle brush may
be used to remove ingrained soil. Avoid scratching by
gentle brushing. Wipe with a clean cloth dampened
with warm water to remove residues. Dry in shade away
from direct heat.
If persistent marks remain visible after cleaning, seek
professional advice.
SAVE THESE INSTRUCTIONS
FCC Compliance:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC Compliance:
To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
change to the antenna or the device could result in the device exceeding the RF exposure requirement and void
and (2) this device must accept any interference received, including interference that may cause undesired operation.
user’s right to operate the device.
To comply with the FCC RF exposure requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device couldresult in the device exceeding the RF exposure requirement and void user’s right to operate the device.
Radio Frequency: 2.4 GHz
Radio Frequency: 2.4 GHz
2
SAVE THESE INSTRUCTIONS
parts list
All electronics and components that need to be installed are located in boxes under the base or
attached to the frame. Before discarding the packing materials, ensure all the parts are accounted for.
* These items are attached to the base for shipping purposes.
Carefully remove from base and set aside.
‡ Only included in Twin, Twin Long, Queen Split and Cal King
Split bases.
Wired Remote
Emergency Battery
PackY-Cord
‡
‡*
OPTIONAL (NOT INCLUDED):
Surge Protector9V Batteries
Actual product appearance and functionality may vary from photographs, illustrations and descriptions included in this manual.
9/16” & 1/2” Socket
and Crescent Wrench
3
390 base overview
Lumbar
Motor
USB PortUSB Port
Head
Massage
Motors
Foot
Motor
Tilt
Motor
Power
Down
Box
Underbed
Lighting
Underbed
Lighting
Head
Motor
Control
Box
Foot
Massage
Motors
Underbed
Lighting
Actual product appearance and functionality may vary from photographs, illustrations and descriptions included in this manual.
4
390 quick reference guide
Not to scale. For illustration purposes only. Read all instructions before beginning installation.
Connection to media
VIBRATION
VIBRATION
faceplates (installed
under the base)
Control
Box
Power
Cord
9V Batteries
(not included)
Power
Supply
Connection ports to
all motors (installed
under base)
Connection to under-
bed lighting (installed
under the base)
Input
Power
Cord
LED Light
Bluetooth 4.0
Power Down
Box
5
330 base overview
Head
Massage
USB Ports*
(optional)
Control
Box
Bluetooth
(optional)
Splitter
(optional)
USB Ports*
(optional)
Foot
Motor
Power
Down
Box
USB
Charger*
(optional)
Foot
Massage
* Available on select models. Actual product appearance and functionality may vary from photographs, illustrations and descriptions included in this manual.
6
Head
Motor
330 quick reference guide
Not to scale. For illustration purposes only. Read all instructions before beginning installation.
Control
Box
Power
Power
Cord
Supply
Input
Power
Cord
Connection ports
to head and foot
motors (massage
and lift). Installed
under the base.
Power Down
Box
9V Batteries
(not included)
* Available on select models. Actual product appearance and functionality may vary from photographs, illustrations and descriptions included in this manual.
7
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.