The KTG-Series is a free standing, pole mount solution for multiple displays.
KTG-320 / KTG-325
KTG-220 / KTG-225
KTG-440 / KTG-445
KTG-230
KTG-330
BEFORE YOU BEGIN
CAUTION!
To prevent damage to the Kit, which could affect or void the Factory warranty, and to the equipment that will be
attached to it, thoroughly study all instructions and illustrations before you begin the installation.
4900 Industry Drive
Central Point, OR 97502
1-800-888-6024
www.ergoindemand.com
Model: KTG-SeriesInstallation Instruc tions
TOOLS REQUIRED FOR INSTALLATION
•Drill and 1/2" drill bit (larger if mounting through a flat surface and using cable management)
•Phillips Head Screw Driver
•3/4" Wrench
•3/32" Hex Key (provided)
•5/32" Hex Key (provided)
•7/32" Hex Key (provided)
INSPECT MOUNT BEFORE ASSEMBLY
Carefully inspect componen ts for shipping damage . If damage is apparent, call your carrier claims agent and do not
continue with installation until the carrier has revie wed the damage.(see Figure 1)
2
Installation InstructionsModel: KTG-Series
Table 1: Parts
QUANTITY By MODEL
ITEM DESCRIPTION220225230320325330440445
10CENTRIS HEAD ASSEMBLY, Pole Mount2
20ARRAY ASSEMBLY, Dual, 27"112
ARRAY ASSEMBLY, Dual, 34"2
30ARRAY ASSEMBLY, Triple, 42"11
ARRAY ASSEMBLY, Triple, 54"1
40PIPE CAP, 1.75 OD11111111
50POLE, Freestand, 14"1111
60POLE, Freestand, 28"1111
70*POLE, Freestand, 42"
80SHEATH, Cable Man agement, 8"11211222
90N/AN/AN/AN/AN/AN/AN/AN/A
100SCREW, Cable Management Grommet Mounting, 3/8-16 x 6"11111111
110GROMMET, Mounting22222222
120KEY, Hex, 5/32"11112111
130KEY, Hex, 3/16"11112111
140KEY, Hex, 7/32"1
160** SCREW, Phi llips Pan H ead, M4 x 12mm8881212241616
170** SCREW, Phi llips Pan H ead, M4 x 20mm8881212241616
180** SCREW, Phi llips Pan H ead, M4 x 30mm8881212241616
190** SPACER, Nylon, 3/8" (used with item 170)8881212241616
200** SPACER, Nylon, 3/4" (used with item 180)8881212241616
210CLAMP, Front, Pole Mount2
220CLAMP, Rear, Pole Mount2
230SCREW, Button Head Cap, 1/4-20 x 1 1/4"66
240CLAMP, Back, Array mounting1111222
250WASHER, Flat, 1/4"2222444
260SCREW, Button Head Cap, 1/4-20 x 3/4"2222444
* Indicates an available optional accessory not included with above models. For additional information pertaining to
available accessories contact a Chief Customer Service represenatative or visit us at www.chiefmfg.com.
** Quantity varies depending upon the number of displays being installed.
3
Model: KTG-SeriesInstallation Instruc tions
(30)
(20)
240
(10 Includes 210, 220, 230)
260
(70)
(50)
250
(60)
(110)
(120)
(80)
(130)
(140)
(100)
(160)
(180)
(200)
(190)
(170)
(40)
Figure 1: Parts
ASSEMBLY AND INSTALLATION
Grommet Mount Installation
To install on a flat surface:
1. Locate desired point on surface where mount is to be
installed. (see Figure 2)
2. Drill a 1/2" dia. hole through surface.
3. Slide one 3/8-16 x 6" HHCS (100) upward through
lower grommet (110), through hole in surface and
through upper grommet (110).
4. Place pole (50, 60, 70) onto upper grommet (110)
aligning threaded hole in pole bottom with threaded
end of 3/8-16 x 6" HHCS (100).
5. Thread 3/8-16 x 6" HHCS (100) into pole bottom (50,
60, 70) and tighten to secure pole and gromme ts
(110) to surface.
6. Add pipe cap (40) to top of pole.
7. Mount Centris head assembly or array assembly to
rail following the instructions outlined in KTG-220,
320, And 440 Assembly section of this document.
(50, 60, 70)
(110)
(110)
(100)
1/2" dia.
through hole
Figure 2: Grommet installation
Mount Assembly
KTG-230 Assembly
8. Place front pole clamp with Centris Head (210)
against pole in approximate mounting location.
9. Place three BHCS (230) into rear p ole clamp (220)
and place against pole aligning with front pole clamp
(210). (see Figure 3)
4
Installation InstructionsModel: KTG-Series
CAUTION!
3. Secure pole mount back (240) to pole mount front and
pole by tightening two BHCS (260) using a 5/32" hex
(210)
key.
(60)
(220)
(230)
Figure 3: Mount Centris Head with Pole Clamp
NOTE: Equally tighten screws (230) against front pole
mount (210) and the rear pole clamp (220). (see
Figure 4)
(230)
Pole
Pole Mount front
with Array
(250)
(260)
Pole Clamp Back (240)
Figure 5: Assemble Array Rail to Pole
Display Installation
Attach Centris Head to Flush Mount Display
(220)
Keep equal
distance between
mount and
clamp when
tightening
(210)
Figure 4: Tightening clamp to mount
10. Secure rear pole clamp (220) to fro nt pole mount
(210) and pole by tightening three BHCS (230) using
5/32" hex key (120). (see Figure 3)
KTG-220, 320, And 440 Assembly
To assemble the KTG-220, 32 0, and 440:
NOTE: If mount is being installed without the base
through a flat surface, proceed to Grommet
Mount Installation.
1. Assemble pole (50) to base (40) using one 3/8-16 x 1"
FHCS (90). (see Figure 2)
CAUTION: If display uses a screw size other than
those included in the kit, DO NOT use the screws
provided. Using the wrong screws could result in
damage to your monitor.
1. Install two M4 x 12mm Phillips pan head screws (160)
into two upper mounting holes in display back.
(see Figure 6)
NOTE: DO NOT fully tighten at this time.
2. Hang display on Centris head. (see Figure 7)
3. Install bottom two M4 x 12mm Phillips pan head
screws (160) through Centris head mounting hol es
and into lower mounting holes in display back.
4. Tighten ALL four M4 x 12mm Phillips pan head
screws (160). (see Figure 8)
2. Assemble pole clamp back (240) to pole mount front
using two FW (250) and two BHCS (260) using a
5/32" hex key. (see Figure 5)
5
Model: KTG-SeriesInstallation Instruc tions
Attach Centris Head to Recessed Mount Display
M4 x 12mm Phillips Pan Head Screw (30)
Display
Figure 6: Prepare Display
NOTE: Refer to Table 1 to select the applicable screw
and spacer combination.
1. Uninstall end lock using the 5/32" hex key (120).
(see Figure 9)
2. Remove Centris head from array rail (20, 30).
Centris Head
Square Nut
(20, 30)
Centris Head
Centris Head
Figure 7: Hang Display
Display
Display
End Lock
(20, 30)
Figure 9: Remove End Lock(s)
(20, 30)
Centris Head
Figure 10: Slide Centris Bracket off Array Rail
3. Place display face down on a clean dry surface.
4. Place four 3/8" or 3/4" nylon spacers (190 or 200)
over four mounting holes in display back (see Figure
11).
(20, 30)
(160)
Figure 8: Secure Display to Cen tris Bracket
6
5. Align Centris head mounting holes with four nylon
spacers (see Figure 11).
6. Secure Centris head to display using four
M4 x 20mm Phillips pan h ead screws (170), or four
M4 x 30mm Phillips pan head screws (180)
(see Figure 11).
Installation InstructionsModel: KTG-Series
Phillips Pan Head Screw
(170 or 180)
End Lock
Centris Head
Spacer
(190 or 200)
(20, 30)
Display
Figure 11: Mount Centris Bracket to Display
7. Slide display with Centris bracket onto array rail (20,
30) (see Figure 12).
NOTE: Repeat previous steps for each additional display.
8. Reinstall end locks into mounting rail using the 5/32"
hex key (120) (see Figure 13).
Display with Centris Bracket
End Lock Retaining Screw
Figure 13: Reinstall End Lock(s)
Centris Head
ADJUSTMENTS
Display Adjustment
The KTG Series mount allows horizontal, pitch, and
rotational adjustment of each display.
The KTG Series mount also allows a full 360 deg. of
display rotation with a maximu m pitch range of 15° up
and 15° down.
Display Horizontal Position Adjustment
To adjust display horizontal position:
1. Loosen Centris bracket rear adjustment knob (see
Figure 14).
2. Slide Centris bracket with display left or right until
properly positioned on array rail.
3. Tighten Centris bracket rear adjustment knob.
(20, 30)
Figure 12: Mount Display with Centris Bracket to
Array Rail
Horizontal
Adjustment
Knob
Figure 14: Display Horizontal Adjustment
7
Model: KTG-SeriesInstallation Instruc tions
Display Pitch and Roll Adjustment
To adjust display pitch or roll position:
1. Loosen Centris bracket front adjustment knob.
(see Figure 15)
2. Tilt display up or down, or adjust display roll left or
right until properly positioned.
3. Tighten Centris bracket front adjustment knob.
Pitch/Roll
Adjustment
Knob
Cable Clips
(80)
Figure 16: Cable Management
Figure 15: Display Pitch and Roll Adjustment
CABLE MANAGEMENT
The KTG Series mount includes cable management
features used to properly route and secure display
cables.
To use the cable management features:
1. Connect cables to display.
2. Route cables through cable clips on array rail.
3. Route cables down pole and away from mount and
secure to pole using sheath (80).
8
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.