WARNING! READ CAREFULLY AND UNDERSTANDALL INSTRUCTIONS BEFORE STARTING INSTALLATION. FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN DEATH OR SERIOUS PERSONAL INJURY.
IMPORTANT
•Equipment should not be altered or modified from its original design without consultation with the manufacturer.
•Equipment which is damaged or becomes damaged during use, handling, or shipping should be set aside and not used.
•WARNING! Failure to anchor unit properly with the correct layout dimensions can result in product damage not covered under warranty –product is not designed to be self supported without anchor bolts. Failure to secure all fasteners may result in death or serious personal injury.
•Do not assemble unit off of anchor bolts and then lift onto them. System should only be assembled in its final location. Never move an assembled system.
•WARNING! Backing plates must be used where designated in the instruction manual. Failure to use backing plates where designated may cause equipment to fail and may result in death or serious personal injury.
•WARNING! After a usage period of 60-90 days, check all fasteners to ensure connections are secure. Periodic inspection is recommended to insure all fasteners are secured. Failure to secure all fasteners may result in death or serious personal injury.
4-29-16
1
Page 3
UNIVERSAL MODULAR PLATFORM SYSTEM
ASSEMBLY CRITERIA
Verify proper installation according to ErectAStep installation manual. In addition, make sure to check the following specifically.
•Ensure all anchor bolts are installed properly at the stair base and tower.
•Ensure leading edge of platform and stair gusset are flush.
•Ensure tower is vertically plumb.
•Ensure all bolts are properly tightened according to ErectAStep installation manual.–No impact wrenches are to be used –tighten all bolts by hand.
•Ensure that stair guardrail posts are vertically plumb.
24-29-16
Page 4
UNIVERSAL MODULAR PLATFORM SYSTEM
INTRODUCTION:ErectAStep modular platform and stair systems are
pre-engineered and designed for unlimited configurations. This universal design allows for optimum flexibility to gain access and egress over and/or around obstructions,equipment, walls, etc.
ErectAStep uses only the highest quality material in the construction of its modular system to ensure the quality, strength, and dependability for years. It is very important to follow configuration guidelines and installation instructions for your ErectAStep system. Design limitations can exist with respect to required supports, adequate footings, and prescribed application.
34-29-16
Page 5
COMPONENTS
PLATFORMS
HANDRAILS
STAIR UNITS
TOWER SUPPORTS
•Complimentary tool kit included in shipment.
•Min 2 people are recommended for assembly.
•Forklifts or cranes may be required based on height and complexity of assemblyconfiguration.
LADDERS
44-29-16
Page 6
SYSTEM ANCHOR LAYOUT
PLAN VIEW
PAD LAYOUT
ANCHOR BOLT POSITION
•Anchor bolt positions should be laid out by mathematically calculating positions of anchors. (see component anchor layout or ErectAStep configurator pad layout for your system)
•NOTICE -Four anchor bolts required for stair unit when six step or greater.
•Layout area for location of your ErectAStep system using measuring tape and chalk lines, keeping anchor lines square and parallel.
•Drill or wet set anchor bolts in the mathematically correct location prior to assembly. Follow any curing procedures recommended by your concrete/anchor bolt supplier.
•Using a level slab/foundation is recommended for anchoring the ErectAStep unit to achieve a good contact point between the bottom of the stairs/supportsand the concrete in lieu of utilizing leveling anchors and shims.
•Once pad layout is complete and you are ready to assemble unit, continue with instructions. Assemble unit on anchor bolts starting with supports, stairs and then connecting platforms, handrails, gussets, etc.
•NOTICE -Do not assemble unit off of anchor bolts and then lift onto them. System should only be assembled in its final location. Never move an assembled system.
54-29-16
Page 7
COMPONENT ANCHOR LAYOUT
Stair Unit5/8” diameter anchor bolts required for 3/4” diameter holes in
base plate.
Two (2) anchor bolts required for units less than 6 step.Four (4) anchor bolts required per stair unit for 6 step stair units
and greater.
Dimensions:A = B + 9”B = # of step X9”
4-29-16
Tower Supports5/8” diameter anchor bolts required for 3/4” x 1 ¼”
slots in base plate.
Four (4) anchors required per tower.
6
Page 8
STACKING COMBINATIONS
STACKINGThree thru six step towers, ladders and stairs can be
stacked to create systems taller than six steps. See samples below:
Recommended larger step sections positioned at bottom of stacked sections.
WARNING!15 step is maximum size without special stair rules.
For 16 step thru 20 step, see ErectAStep configurator or sales representative. Failure to adhere to special stair rules may result in death or serious injury.
4-29-16
NOTICE:One and two step towers, ladders and stairs are not
used in stacking.
7
Page 9
PLATFORM SLOT USAGE
Platforms are designed with slots to allow for adjusting positions of handrails and stair units.
CAUTION!Certain configurations can create pinch
points.
Platform slot design allows for mounting adjustments to deter pinch points.
Handrails or stair units can make use of these slots in order to avoid pinch points.
NOTICE: Be sure to account for dimensional change in anchor bolt layout when sliding stair unit over.
84-29-16
Page 10
TOWER COMPONENTS
1 AND 2 STEP
Tower order part numbers1 Step –Part #900112 Step –Part #90012
Hardware kit for 1 or 2 StepPart #55996
NOTICE: 1 and 2 steps can not be used when stacking towers.
STEP 2: Attach hardware as shown and tighten hardware.
NOTICE: Some components may ship pre-assembled. Disassemble base from tower if used as middle or upper section when stacking.
124-29-16
Page 14
TOWER INSTRUCTIONS –TOP MEMBER
STEP 3: Orient components as shown.
STEP 4: Attach hardware and tighten as shown.
NOTICE: Some components may ship pre-assembled. Disassemble top member from tower if used as middle or lower section of stacking.
134-29-16
Page 15
TOWER INSTRUCTIONS –TOP BRACKETS
STEP 5: Orient components and add hardware as shown.
STEP 6: Tighten hardware.
144-29-16
Page 16
TOWER INSTRUCTIONS –STACKED SECTION
STEP 1: Orient components as needed for the desired tower height.
STEP 2: At each stacked section joint, attach brackets and add hardware as shown and tighten hardware.
See previous sheets for instruction on base, top member, and top bracket connections.
NOTICE: If ladder assembly is to be attached to the tower, this should be done at this time prior to installation at final anchor location (for ease of installation).
154-29-16
Page 17
TOWER/PLATFORM CONNECTIONS
Flush bolting arrangement used when supporting one platform.
Bolting diagramFlush bolting (shown) uses
outside set of holes in tower.
Split bolting arrangement used when supporting two platform (tower located at joint between platforms).
Split bolting uses inside set of holes in tower.
NOTICE: Bolt orientation should be with bolt head up.
164-29-16
Page 18
TOWER/PLATFORM CONNECTIONS
When tower and stairs are both used at the end of a platform, omit indicated hardware from tower assembly. These bolts will interfere with top step of stair unit.
Tower base plate and top cross member are slotted. Slide the tower as indicated to allow for flush mount of the stair unit to the platform.
Notice: Stair unit brackets will not be used in this configuration.
174-29-16
Page 19
LADDER/TOWER COMPONENTS
1 AND 2 STEP
Ladder/tower order part numbers1 Step –Part #900312 Step –Part #90032
Hardware kit for 1 or 2 StepPart #55988
NOTICE: 1 and 2 steps can not be used when stacking ladders.
184-29-16
Page 20
LADDER/TOWER COMPONENTS
3 THRU 6STEP
Ladder/tower order part numbers3 Step –Part #900334 Step –Part #900345 Step –Part #900356 Step –Part #90036
Hardware kit for 3 thru 6stepPart #55995
See tower instructions for tower section of ladder/tower unit.
194-29-16
Page 21
LADDER INSTRUCTIONS
LADDER CONFIGURATION 3 STEPTHRU 6 STEPASSEMBLY
NOTICE: May ease erection by mounting ladder to tower during tower assembly prior to setting towers.
STEP 1Orient components as shown for non-stacked sections
(3 thru 6 step).
STEP 2With set screw removed, slide couplers into lower section, insert set
screw thru hole of lower section and loosely secure. Then slide upper section over couplers and secure by tightening both set screws.
204-29-16
Page 22
LADDER/TOWER INSTRUCTIONS
LADDER CONFIGURATION 3 STEP THRU 6 STEPASSEMBLY
STEP 3:Attach assembled ladder to tower as
shown. Upper hardware will attach to platform. Tighten hardware both sides of ladder (only one side shown).
NOTICE: Ladder step size must match tower size in order for mounting holes to line up.
NOTICE: Backing plates supplied with platform
4-29-16
WARNING! Backing plate must be used at this connection. Failure to use backing plates may cause equipment to fail and may result in death or serious personal injury.
21
Page 23
LADDER INSTRUCTIONS
LADDER CONFIGURATION STACKED ASSEMBLIES (GREATER THAN 6 STEP)
STEP 1:Orient components as shown for stacked
assemblies. (See instructions for connecting ladder sections.)
NOTICE: Ladder step size configuration must match tower size configuration in order for mounting holes to line up.
Example: If tower is configured as 6 step on bottom and 4 step on top, then lower unit of ladder must be 6 step and upper unit of ladder must be a 4 step.
NOTICE: Ladder spacer section is only used between stacked units.
NOTICE: May ease erection by mounting ladder to tower during tower assembly prior to setting towers.
224-29-16
Page 24
LADDER INSTRUCTIONS
LADDER CONFIGURATION STACKED ASSEMBLIES (GREATER THAN 6 STEP)
STEP 2With set screw removed, slide couplers into lower section, insert set
screw thru hole of lower section and loosely secure. Then slide upper section over couplers and secure by tightening set screw.
NOTICE:Repeat procedure for every ladder joint.
234-29-16
Page 25
LADDER/TOWER INSTRUCTIONS
LADDER CONFIGURATION STACKED ASSEMBLIES (GREATER THAN 6 STEP)
STEP 3:Attach assembled ladder to tower as
shown. Upper hardware will attach to platform. Tighten hardware both sides of ladder (only one side shown).
NOTICE: Ladder step size configuration must match tower size configuration in order for mounting holes to line up.
Example: If tower is configured as 6 step on bottom and 4 step on top, then lower unit of ladder must be 6 step and upper unit of ladder must be a 4 step.
4-29-16
WARNING! Backing plate must be used at this connection. Failure to use backing plates may cause equipment to fail and may result in death or serious personal injury.
24
Page 26
STAIR COMPONENTS
1 AND 2 STEP
Stair order part numbers1 Step –Part #900012 Step –Part #90002
NOTICE: 1 and 2 steps not used when stacking stairs.
254-29-16
Page 27
STAIR COMPONENTS
3 THRU 6 STEP
Stair order part numbers3 Step –Part #900034 Step –Part #900045 Step –Part #900056 Step –Part #90006
Hardware kit for 3 thru 6 step -Part #56000
Some components may ship pre-assembled.
NOTICE: Stair rail mid section and casting stair connectors are only used in stacking configurations.
264-29-16
Page 28
STAIR COMPONENTS
3 THRU 6 STEP(CON’T)
Some components mayship pre-assembled.
274-29-16
Page 29
STAIR RAIL INSTRUCTIONS
3 THRU 6 STEP
STEP 1Orient components as
shown.
STEP 2Insert pipe couplers into the filler pipes.
Insert coupler set screw and loosely tighten.
STEP 3Slide all components together, then
securely tighten coupler set screw.
284-29-16
Page 30
STAIR STRINGER INSTRUCTIONS
3 THRU 6 STEP
4-29-16
STEP 1Orient components as
shown.
STEP 2Insert and securely tighten hardware (see
next sheet for detailed views).
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
Some components may ship
pre-assembled.
29
Page 31
STAIR STRINGER INSTRUCTIONS
3 THRU 6 STEP
4-29-16
NOTICE:Some holes are used to connect both casting to stringer as well as connect
stair steps and/or handrails.Hardware to bolt to platform must be inserted prior to installing stair handrails.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
30
Page 32
STRINGER/STAIR RAIL INSTRUCTIONS
Some components may ship pre-assembled.
3 THRU 6 STEP
STEP 1Slide rail insert into stair handrails.Orient steel side towards stringer.(May require tape to hold in place while assembling).STEP 2Position stair handrails on to stringer with handrail spacers
(spacers only needed at stringer connection –castings have spacer incorporated.
STEP 3Insert hardware and tighten hardware.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
4-29-16
31
Page 33
STAIR UNIT INSTRUCTIONS
3 THRU 6 STEP
STEP 1Orient left and right stringer assembly sections as shown and
bolt in all steps.STEP 2Securely tighten all step hardware.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
4-29-16
32
Page 34
STAIR UNIT INSTRUCTIONS
3 THRU 6 STEP
STEP 3Attach both left and right brackets with backing plate as shown and securely tighten
hardware.STEP 4Attach cross brace under stairs as shown and securely tighten hardware. Position of cross
brace should be in middle of stringer.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
NOTICE: The hardware orientation for stair cross braces should be installed with bolt head down to avoid injury when accessing under stair unit.
4-29-16
33
Page 35
STAIR UNIT INSTRUCTIONS
STAIR CONFIGURATION STACKED ASSEMBLIES (GREATER THAN 6 STEP)
Upper stacked section
NOTICE:Follow all instructions for the 3 thru 6 step units.
However when stacking stair units, stinger and stair handrails are connected using the stair rail mid section and the casting stair connector between each stacked section.
Crossbrace under stairs should alternate direction from one stacked section to another.
4-29-16
Lower stacked section
34
Page 36
PLATFORM COMPONENTS
Platform order part numberPlatform –Part #11394
Hardware kit for platform –Part #56003
PLATFORM
BACKING
PLATE
4-29-16
PLATFORM
35
Page 37
PLATFORM CONNECTIONS
STEP 1Align platforms as shown.
STEP 2Insert hardware and tightensecurely as shown.
WARNING! Backing plate must be used at this connection. Failure to use backing plates may cause equipment to fail and may result in death or serious personal injury.
Position backing plates as close to platform corners as possible .
PLATFORM TO PLATFORM
NOTICE:No more than 3 platforms can be
connected without supports.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
4-29-16
36
Page 38
PLATFORM CONNECTIONS
HANDRAIL TO PLATFORM
STEP 1Slide rail insert into handrails. Orient steel side towardsplatform. May require tape to hold in place while assembling.STEP 2Position handrails on to platform as shown.STEP 3Insert hardware and tighten hardware.
NOTICE: Metal piece should be oriented so that nuts are facing plastic.
WARNING! Backing plate must be used at this connection. Failure to use backing plates may cause equipment to fail and may result in death or serious personal injury.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
4-29-16
37
Page 39
PLATFORM CONNECTIONS
STAIRS TO PLATFORM
STEP 1Position platform and stairs as shown . Connect vertical face of
stairs to vertical face of platform using bolt inserted during stair stringer instructions. Securely tighten hardware.
WARNING! Backing plate must be used at this connection. Failure to use backing plates may cause equipment to fail and may result in death or serious personal injury.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
4-29-16
STEP 2Connect platform to stair bracket with hardware as shown and
securely tighten.
38
Page 40
PLATFORM CONNECTIONS
PLATFORM TO BOTTOM OF STAIRS
STEP 1Position platform and stairs as shown. Connect using hardware and backing plates
as shown. Securely tighten hardware.
NOTICE: When using this configuration, bolts used to attach platform to stair must be installed before attaching stair handrails.
WARNING! Backing plate must be used at this connection. Failure to use backing plates may cause equipment to fail and may result in death or serious personal injury.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
4-29-16
39
Page 41
PLATFORM CONNECTIONS
REMOVABLE HANDRAILTO PLATFORM
STEP 1Loosely attach handrail sockets using hardware and backing plates.
4-29-16
STEP 2Slide handrails into sockets for fit and alignment, then tighten hardware.
NOTICE:Sockets should be plumb and square to allow handrails to slide in and out.
WARNING! Backing plate must be used at this connection. Failure to use backing plates may cause equipment to fail and may result in death or serious personal injury.
WARNING! Do not use impact wrench. May cause damage to unit which could result in serious personal injury or death. See torque data.
40
Page 42
HARDWARE CONNECTIONS
Ladder hardware kit1 & 2 step: Bolt ½” x 1 ½” , Bolt ½” x 5 ½”, Nut ½”3 step thru 6 step: Bolt ½” x 1 ½”, Nut ½”, 2” Square Coupling (set screw 3/8” x 1 5/8” Long –3/16 allenwrench)
OSHA 1910.23(e)(1) A standard railingshall consist of top rail, intermediate rail,and posts, and shall have a vertical heightof42 inches nominal from upper surface oftop rail to floor, platform, runway, orramp level. The top rail shallbe smooth surfacedthroughout the length of the railing. The intermediate rail shall be approximatelyhalfwaybetween the top rail andthe floor, platform, runway, or ramp. The ends ofthe railsshallnot overhangthe terminalposts except where such overhangdoes not constitute a projection hazard.
OSHA 1910.23(e)(5)(iv)The mountingof handrailsshallbe such that the completed structure iscapable ofwithstandingaload ofat least 200 pounds applied in any direction at anypoint on the rail.
OSHA 1910.23(e)(6) All handrails and railingsshall be provided with a clearance ofnot less than 3 inches between thehandrail or railingand anyother object.
OSHA 1910.23(e)(3)(ii) For pipe railings, posts and top and intermediate railingsshall be at least 1-1/2 inches nominaldiameterwith posts spaced not morethan 8 feet on centers.
OSHA 1910.23(e)(2) A stair railingshall be ofconstruction similar to a standard railingbut the vertical height shall be notmore than 34 inches nor less than 30 inches from uppersurface oftop railto surface oftread inline with face ofriseratforward edge oftread.
OSHA 1910.24(c)“Stair strength.” Fixed stairways shallbe designed and constructed to carrya load offivetimes thenormal live load anticipated but neverofless strength than to carrysafely a movingconcentrated load of1,000 pounds.
OSHA 1910.24(e) “Angleofstairwayrise.”Fixed stairsshall be installed at angles to the horizontalofbetween 30 deg.and 50 deg. Any uniformcombination ofrise/tread dimensions may be used that will result in a stairwayat an angle to thehorizontal within the permissible range. Table D-1 gives rise/tread dimensions which will produce a stairway within thepermissible range, statingthe angle to the horizontalproduced byeach combination. However,the rise/tread combinationsare not limited to those given in Table D-1.
Angle to horizontalRise (in inches) Table D-1Tread run (in inches)30 deg. 35’6-1/21132 deg. 08’6-3/410-3/433 deg. 41’710-1/235 deg. 16’7-1/410-1/436 deg. 52’7-1/21038 deg. 29’7-3/49-3/440 deg. 08’89-1/241 deg. 44’8-1/49-1/443 deg. 22’8-1/2945 deg. 00’8-3/48-3/446 deg. 38’98-1/248 deg. 16’9-1/48-1/449 deg. 54’9-1/28
OSHA 1910.24(f) “Stairtreads.”Alltreads shallbe reasonablyslip-resistant and the nosings shallbe ofnonslipfinish.Welded bargratingtreads without nosingsare acceptable providingthe leadingedge can be readilyidentified bypersonneldescendingthe stairwayand provided the tread is serrated or is ofdefinite nonslipdesign. Rise height and tread width shallbe uniformthroughout anyflight ofstairs includingany foundation structure used as one or moretreads ofthe stairs.
OSHA 1910.144(a)(3)Yellow.Yellowshallbe the basic colorfordesignatingcaution and formarkingphysicalhazards suchas: Strikingagainst, stumbling,falling, tripping, and “caught in between.”
OSHA 1926.451(f)(16)Platforms shallnot deflect morethan 1/60 of the span when loaded.
424-29-16