Equalizer HP350SD, HP550SD, HP1000SD Operator's Instruction Manual

HP350SD, HP550SD HP1000SD
DOUBLE ACTING HYDRAULIC SEALED
HAND PUMPS
Operator Instruction Manual
info@equalizerinternational.com
www.equalizerinternational.com
INDEX
SECTION CONTENTS PAGE NO.
1 INTRODUCTION 1
2 SAFETY INFORMATION 2-3
3 KIT COMPONENTS 4
4 TECHNICAL DATA 5
5 HOW THE HAND PUMPS WORK 6
6 INSTALLATION AND OPERATION 7-9
6.1 HP350SD, HP550SD, HP1000SD
7-9
7 EXAMINATION, MAINTENANCE AND STORAGE 10
8 PARTS LISTS 11-13
9 WEIGHTS AND DIMENSIONS 14
10 TROUBLESHOOTING 15-16
1. INTRODUCTION
The HP350SD, HP550SD and HP1000SD Hydraulic Hand Pumps output is regulated to 700
bar (10,000 psi) and is delivered from an output port threaded ⅜” NPT. The HP350SD,
HP550SD and HP1000SD can be used with any double acting 700 bar (10,000 psi) rated hydraulic equipment.
The diaphragm oil reservoir means that, unlike conventional hand pump units, the HP350SD, HP550SD and HP1000SD are operable at all angles and are highly resistant to accidental
spillage of hydraulic uid.
Pressure rating:
1st stage: 13.8 bar (197 psi)
2nd stage: 700 bar (10,000 psi)
HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL
HPSD_IM_REV_04
06/06/14
PAGE 1
2. SAFETY INFORMATION
The operator MUST read this manual prior to using the tools.
Failure to comply with the following cautions and warnings could cause equipment
damage and personal injury; read the manual fully!
Read all the following instructions, warnings and cautions carefully. Follow all safety
precautions to avoid personal injury or property damage during system operation.
Equalizer International Ltd cannot be responsible for damage or injury resulting from unsafe
product use, lack of maintenance or incorrect product and/or system operation. Contact
Equalizer International Ltd when in doubt as to the safety precautions and applications. To
protect your warranty, use only good quality hydraulic oil of the grade 15cSt.
Only people competent in the use of hydraulic equipment should use these tools.
In all installations the site safety requirements must be adhered to. ALSO the safety of the
operator, and when present, any assisting personnel, is of paramount importance along with
the safety of others including, when present, the general public.
These instructions are only to cover the safe operation of THE EQUALIZER HP350SD, HP550SD
AND HP1000SD HYDRAULIC SEALED HAND PUMPS during normal maintenance/installation
operations. All other safety aspects must be controlled by the operation supervisor.
HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL
PAGE 2
A CAUTION is used to indicate correct operating or maintenance procedures and practices to prevent damage to, or destruction of equipment or other property.
A WARNING indicates a potential danger that requires correct procedures or practices to avoid personal injury.
A DANGER is only used when your action or lack of action may cause serious injury or even death.
IMPORTANT: Operator must be competent in the use of hydraulic equipment. The operator must have read and understood all instructions, safety issues, cautions and warnings before starting to operate the Equalizer equipment.
WARNING: To avoid personal injury and possible equipment damage, make sure all hydraulic components are rated to a safe working pressure of 700 bar (10,000 psi)
WARNING: Do not overload equipment. Over­loading causes equipment failure and possible personal injury.
CAUTION: Make sure that all system compo­nents are protected from external sources of damage, such as excessive heat, ame, mov­ing machine parts, sharp edges and corrosive chemicals.
CAUTION: Avoid sharp bends and kinks that will cause severe back-up pressure in hoses. Bends and kinks lead to premature hose failure. Do not drop heavy objects onto hoses. A sharp impact may cause internal damage to hose wire strands; applying pressure to a damaged hose may cause it to rupture. Do not place heavy weights on the hoses, or allow vehicles to roll over the hoses; crush damage will lead to pre­mature hose failure.
WARNING: Immediately replace worn or damaged parts with genuine Equalizer
parts. Equalizer parts are designed to t
properly and withstand rated loads. For repair or maintenance service contact your Equalizer distributor or service centre.
DANGER: To avoid personal injury keep hands and feet away from the tool and workpiece during operation.
WARNING: Always wear suitable clothing and Personal Protective Equipment (PPE).
DANGER: Do not handle pressurised hos­es. Escaping oil under pressure can pen­etrate the skin, causing serious injury. If oil is injected under the skin, seek medical attention immediately.
WARNING: Never pressurize unconnected couplers. Only use hydraulic equipment in a connected system.
IMPORTANT: Do not lift hydraulic equip­ment by the hoses or couplers. Use the car­rying handle or other means of safe trans­port.
CAUTION: Do not operate the equipment without lubricating all moving parts. Use only high pressure molybdenum disulphide grease.
HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL
PAGE 3
3. KIT COMPONENTS
HP350SD KIT COMPONENTS
1 x HP350SD Pump Unit 1 x Pressure Gauge
1 x ⅜” Port Gauge Adaptor
1 x Instruction Manual 1 x Cardboard Packaging
Product Code: HP350SDMIN
HP550SD KIT COMPONENTS
1 x HP550SD Pump Unit 1 x Pressure Gauge
1 x ⅜” Port Gauge Adaptor
1 x Instruction Manual 1 x Cardboard Packaging
Product Code: HP550SDMIN
HP1000SD KIT COMPONENTS
1 x HP1000SD Pump Unit 1 x Pressure Gauge
1 x ⅜” Port Gauge Adaptor
1 x Instruction Manual 1 x Cardboard Packaging
Product Code: HP1000SDMIN
HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL
PAGE 4
Loading...
+ 12 hidden pages