Equalizer HP350S, HP350D, HP1000S, HP550S, HP1000D Operator's Instruction Manual

...
OPERATOR INSTRUCTION MANUAL
HP350S/HP350D HP550S/HP550D HP1000S/HP1000D
EQUALIZER INTERNATIONAL LTD
www.equalizerinternational.com
HYDRAULIC SEALED HAND PUMPS
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
1
CONTENTS
1. INTRODUCTION
2. TOOL SAFETY
2.1 GENERAL SAFETY
2.2 PERSONNEL COMPETENCY
2.3 DISCLAIMER
2.4 DEFINITION OF TERMS
2.5 HAZARDS
3. GENERAL HAND PUMP OPERATION
3.1 GENERAL GUIDANCE
3.2 HP350S, HP550S & HP1000S INSTALLATION AND OPERATION
3.3 HP350D, HP550D & HP1000D INSTALLATION AND OPERATION
3.4 USE OF EQUALIZER INTERNATIONAL TOOLS WITH A HYDRAULIC MANIFOLD
4. HAND PUMP MAINTENANCE
4.1 INSPECTION
4.2 CLEANING
4.3 MAINTENANCE
4.4 STORAGE & TRANSPORTATION
4.5 SUB-SEA USAGE
4.6 LONG-TERM STORAGE - MAINTENANCE PLAN
5. TECHNICAL SPECIFICATIONS
5.1 TECHNICAL DATA
5.2 KIT CONTENTS
5.3 HP350S, HP550S & HP1000S WEIGHTS AND
DIMENSIONS
5.4 HP350D, HP550D & HP1000S WEIGHTS AND
DIMENSIONS
6. TROUBLESHOOTING
6.1 HP350S/HP550S/HP1000S HP350D/HP550D/
HP1000D TROUBLESHOOTING
7. REGULATORY INFORMATION
7.1 REGISTERED HEAD OFFICE
8. PARTS LISTS & SERVICE KITS
15/05/2018
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
2
1.
INTRODUCTION
The Equalizer™ HP-S hydraulic single-port sealed hand pump and HP-D hydraulic twin-port sealed hand pump replace the Equalizer P142 hydraulic hand pump.
The HP350S, HP550S, HP1000S and HP350D, HP550D and HP1000D are tailored for use with Equalizer International Ltd hydraulic equipment. Their output is regulated to 700 bar (10 000psi) and is delivered from an output port
threaded ⅝” NPT.
The HP350S and HP350D can be used with any 700 bar (10 000 psi) rated hydraulic equipment with an oil capacity of 350 cc (21.4 in
3
) or less.
The HP550S and HP550D can be used with any 700 bar (10 000 psi) rated hydraulic equipment with an oil capacity of 550 cc (33.6 in
3
) or less.
The HP1000S and HP1000D can be used with any 700 bar (10 000 psi) rated hydraulic equipment with an oil capacity of 1000 cc (61.0 in
3
) or less.
The diaphragm oil reservoir means that, unlike conventional hand pump units, the HP-S and HP-D pump ranges are operable at all angles and are highly resistant
to accidental spillage of hydraulic uid.
PRESSURE RATING:
1st stage: 13.8 bar (197 psi)
2nd stage: 700 bar (10 000 psi)
2.
TOOL SAFETY
2.1
GENERAL SAFETY
These instructions cover the safe operation and maintenance of THE EQUALIZER HP350S, HP550S, HP1000S, HP350D, HP550D and HP1000D HYDRAULIC SEALED HAND PUMPS. The use of these tools should be as part of a broader task-based risk assessment, which should be carried out by the operation supervisor or other competent person.
Failure to comply with the safety information contained within this manual could result in personal injury or equipment damage. Read all instructions, warnings and cautions carefully, and follow all safety precautions.
The safety of the operator, any assisting personnel and the general public is of paramount importance. Always work in accordance with applicable national, local, site & company-wide safety procedures.
2.2
PERSONNEL COMPETENCY
Only personnel deemed competent in the use of mechanical and hydraulic equipment should use these tools.
2.3
DISCLAIMER
Equalizer cannot be held responsible for injury or damage resulting from unsafe product use, lack of maintenance or incorrect product and/or system operation. If in doubt as to the safety precautions and applications, contact Equalizer using the contact details at the back of this manual.
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
3
2.4
DEFINITION OF TERMS
A CAUTION is used to indicate correct operating or maintenance procedures and practices to prevent damage to, or destruction of equipment or other property.
A WARNING indicates a potential danger that requires correct procedures or practices to avoid personal injury.
A DANGER is only used when your action or lack of action may cause serious injury or even death.
DO: an illustration showing how the tool should be used.
DON’T: an illustration showing an incorrect way to use a tool.
2.5
HAZARDS
IMPORTANT: Operator must be competent in
the use of hydraulic equipment. The operator must have read and understood all instructions, safety issues, cautions and warnings before starting to operate the Equalizer equipment.
WARNING: To avoid personal injury and possible equipment damage, make sure all hydraulic components are rated to a safe working pressure of 700 bar (10,000 psi)
WARNING: Do not overload equipment. Overloading causes equipment failure and possible personal injury.
CAUTION: Make sure that all system components are protected from external sources of damage, such as excessive heat,
ame, moving machine parts, sharp edges and
corrosive chemicals.
CAUTION: Avoid sharp bends and kinks that will cause severe back-up pressure in hoses. Bends and kinks lead to premature hose failure. Do not drop heavy objects onto hoses. A sharp impact may cause internal damage to hose wire strands; applying pressure to a damaged hose may cause it to rupture. Do not place heavy weights on the hoses, or allow vehicles to roll over the hoses; crush damage will lead to premature hose failure.
WARNING: Immediately replace worn or damaged parts with genuine Equalizer parts.
Equalizer parts are designed to t properly and
withstand rated loads. For repair or maintenance service contact your Equalizer distributor or service centre.
DANGER: To avoid personal injury keep hands and feet away from the tool and workpiece during operation.
WARNING: Always wear suitable clothing and Personal Protective Equipment (PPE).
DANGER: Do not handle pressurised hoses. Escaping oil under pressure can penetrate the skin, causing serious injury. If oil is injected under the skin, seek medical attention immediately.
WARNING: Never pressurize unconnected couplers. Only use hydraulic equipment in a connected system.
IMPORTANT: Do not lift hydraulic equipment by the hoses or couplers. Use the carrying handle or other means of safe transport.
CAUTION: Do not operate the equipment without lubricating all moving parts. Use only high pressure molybdenum disulphide grease.
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
4
3.
GENERAL HAND PUMP OPERATION
3.1
GENERAL GUIDANCE
The release valve is closed fully by rotating clockwise until hand tight
CLOSE RELEASE
VALVE
The pump handle is raised, which creates a vacuum in the piston chamber which sucks oil from the reservoir into the chamber
The pump handle is depressed, which pumps the oil from the chamber through the outlet port and into the system to which the pump is connected
Steps 2 & 3 are repeated, which will pump oil into the system until the maximum pressure of 700 bar (10 000 psi) is achieved, at which point the safety release valve will open and the oil will cycle back to the reservoir
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
5
3.2
HP350S, HP550S & HP1000S CONNECTION AND OPERATION
WARNING: Never attempt to pressurise the
pump when the pressure gauge is not connected or the pump is not connected to a system.
DANGER: Always check the hydraulic system in which the pump is to be used, is rated for 700 bar (10 000 psi). Over pressurizing a hydraulic system will result in component failure and personal injury.
1. Prior to using the pump the hydraulic gauge must be
tted. Push the male connector on the gauge fully
into the female connector on the gauge adaptor and rotate the locking ring counterclockwise until fully tight.
LOCKING
RING
2. Ensure the hydraulic system you wish to pressurise
has been bled and is free from air and leaks. Connect the pump into the system using the screw connector supplied with the pump, push the male and female connectors together fully and rotate the locking ring clockwise until fully tight.
WARNING: Never disconnect the pump or other components when the system is pressurised.
LOCKING
RING
MALE AND FEMALE
CONNECTORS
3. Close the release v alve fully by rotating clockwise until
hand tight.
CLOSE RELEASE
VALVE
4. Pressurise the system by raising and depressing the
pump handle until the desired pressure is indicated on the pressure gauge. N.B. max. pressure 700 bar (10 000 psi).
5. To depressurise the system, gently open the release
valve by rotating the release knob anti-clockwise
OPEN RELEASE
VALVE
6. Once the system has been fully depressurised,
the pump can be disconnected by unscrewing the connectors.
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
6
3.3
HP350D, HP550D & HP1000D CONNECTION AND OPERATION
The HP350D, HP550D and HP1000D pumps have been designed for use with Equalizer maxi kit systems; however the HP350D, HP550D and HP1000D can be used in any situations where two separate hydraulic systems require to be pressurised and controlled independently by the same operator.
WARNING: Never attempt to pressurise the pump when the pressure gauge is not connected or the pump is not connected to a system.
DANGER: Always check the hydraulic system in which the pump is to be used, is rated for 700 bar (10 000 psi). Over pressurizing a hydraulic system will result in component failure and personal injury.
1. Prior to using the pump, the hydraulic gauges must
be tted. Push the male connector on the gauges
fully into the female connector on the gauge adaptors and rotate the locking ring counterclockwise until fully tight.
2. Ensure the hydraulic systems you wish to pressurise
have been bled and are free from air and leaks. Connect the pump into the systems using the screw connectors supplied with the pump, push the male and female connectors together fully and rotate the locking rings clockwise unti fully tight.
WARNING: Never disconnect the pump or other componnents when the system is pressurised.
MALE AND FEMALE
CONNECTORS
LOCKING
RING
LOCKING
RING
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
7
3. The HP-D pumps are tted with two control valves and
a release valve. This enables the operator to adjust the pressure on both hydraulic systems independently or simultaneously.
CONTROL VALVE 1
CONTROL VALVE 2
RELEASE VALVE
a. If control valves 1 and 2 are set to the fully open
position and the release valve is screwed fully, when the pump handle is raised and lowered both hydraulic systems will be pressurised to an equal pressure (max. 700 bar (10 000 psi)).
b. If control valve 1 is open and control valve 2
is closed with the release valve screwed fully, when the pump handle is raised and lowered only the system connected to control valve 1 will be pressurised (max. 700 bar (10 000 psi)).
c. If control valve 2 is open and control valve 1 is
closed with the release valve screwed fully, when the pump handle is raised and lowered only the system connected to control valve 2 will be pressurised (max. 700 bar (10 000 psi)).
OPERATOR INSTRUCTION MANUAL
IM_HP_Rev10_A4
HP350S; HP350D; HP550S; HP550D; HP1000S; HP1000D
HYDRAULIC SEALED HAND PUMPS
8
d. If after pressurising one system the control valve
for the unpressurised system is opened then the pressure in both systems will adjust until they are equal.
4. a.
To depressurise both systems simultaneously, open both control valves and gently open the release valve by rotating the release knob anti­clockwise.
b. To depressurise only one system, open only the
control valve for that system and gently open the release valve by rotating the release knob anti-clockwise.
5. At any time, during pressurisation of the systems,
the appropriate control can be closed to hold one
system at a xed pressure while the pressure in
the other system can be increased by raising and lowering the pump handle or decreased by opening the release valve.
6. Once both systems have been fully depressurized
the pump can be disconnected by unscrewing the couplers