Epicenter 2x8, 2x16 User Manual

Centerpoint 2x16 and 2x8
Installation and User’s Manual
Epicenter Inc. 211B Calle Pintoresco San Clemente, CA 92672 949-366-5370
www.epicenterinc.com
Epicenter, Inc. Centerpoint User Guide
The information contained in this guide is subject to change without notice. Epicenter Inc. shall not be liable for technical or editorial errors or omissions contained herein; nor
is it liable for incidental or consequential damages resulting from the furnishing, performance, or use of this material.
Product names mentioned herein may be trademarks and/or registered trademarks of their respec­tive companies. PC/AT, PS/2 and RS/6000 are registered trademarks of International Business Machines Corporation. Sun Microsystems and Sun SPARC are registered trademarks of Sun Mi­crosystems, Inc. Epicenter, Centerpoint, Centerview and Centercade are trademarks of Epicenter Inc.
Epicenter Inc.
211B Calle Pintoresco
San Clemente, CA 92672
Phone 949-366-5370
Fax 949-366-5380
Email sales@epicenterinc.com
Web site www.epicenterinc.com
PN:1100-00000294
Revision A2
T
Introduction................................................................................................ 4
Using This Manual..................................................................................... 5
Safety Warnings and Cautions................................................................... 6
Product Features ....................................................................................... 7
Rack Mount Installation.............................................................................. 8
Centerpoint Connections ....................................................................... 9
On-Screen Controls ................................................................................... 10
Operation................................................................................................... 14
TFT Setup and Controls............................................................................. 15
Appendices
One Year Warranty ........................................................................ 17
Factory Default Settings ................................................................. 18
Installing Updates........................................................................... 19
Fuse replacement and Maintenance .............................................. 20
Regulatory Information................................................................... 21
Specifications................................................................................. 22
Connecting to a Sun Server ........................................................... 23
ABLE OF CONTENTS
Epicenter, Inc.
Page 3
I
NTRODUCTION
PRODUCT OVERVIEW
The Fully Integrated KVM Solution Epicenter’s Centerpoint, 2x8 and 2x16 are Keyboard, Video and Mouse (KVM) solutions that inte-
grate 16 or 8 port switches with a 14.1” TFT display, keyboard and mouse control in a single 1.75” high unit. Centerpoint is a one-stop solution to managing your rack-mounted servers. One control unit eliminates wasted rack space and provides you with control of up to 16 or more servers in a single, compact, design.
FEATURES
Fill your rack with processing power! As server density increases, giving up valuable rack space for management consoles becomes a
critical issue. Centerpoint 2x8 and 2x16 can reduce the space requirements for your KVM switch, monitor, keyboard and mouse to only 1U.
16 or 8 port keyboard, video and mouse (KVM) switch
Access to any of the 8 or 16 ports by two users
Integrated 14.1” flat panel display
1U rack mount chassis - 1.75"
On-screen interface software for server selection
Full 83 key, low-profile, notebook keyboard
Glidepoint touch pad
Unique high density cable design reduces cable clutter and eases installation
Windows 98 and higher, Linux and Solaris compatible
Includes all rack mounting hardware
External video, keyboard and mouse ports for remote monitoring and control
Option for built-in long line drivers for remote monitoring and control
Multiple on-board processors monitor each port to assure availability
Epicenter, Inc.
Page 4
U
This manual covers the Centerpoint 2x8 and Centerpoint 2x16 two-user models. Centerpoint 2x8 provides two user access to up to eight servers through the eight integral KVM ports. Centerpoint 2x16 provides two user access to up to 16 servers through the 16 integral KVM ports.
Generally, all of this information in this user manual pertains to both products. However, the number of accessible ports ( 16 or 8) controls what will be seen on the On-Screen display. For example, in the section on On-Screen controls some of the sample screens show multiple pages to accommodate the 16 ports found on Centerpoint 2x16. If you are using the Centerpoint 2x8 models, only one page is required to display all of the available port options. Therefore, you will not see previous and next on those screens and only a single screen will be displayed.
SING THIS MANUAL
Epicenter, Inc.
Page 5
S
DO NOT open top cover, Hazardous Voltages Present!
When mounting Centerpoint 2x16 or Centerpoint 2x8 heating issues must be taken into account!
Centerpoint 2x8 and Centerpoint 2x16 must be mounted in a way that ensures
the integrity of the rack!
Use caution when lowering monitor! Fingers may be pinched.
Do not lean on drawer when pulled out!
DO NOT OPEN CENTERPOINT. There are no user serviceable parts inside and opening or remov­ing covers may expose you to dangerous shock hazards or other risks. Refer all servicing to quali­fied service personnel.
Do not spill any liquids into the cabinet or use your monitor near water.
Do not insert objects of any kind into the cabinet slots, as they may touch dangerous voltage points, which can be harmful or fatal or may cause electric shock, fire or equipment failure.
Do not place any heavy objects on the power cord. Damage to the cord may cause shock or fire.
Do not place this product on a sloping or unstable cart, stand or table, as the monitor may fall, causing serious damage to the monitor.
When operating Centerpoint 2x16 or Centerpoint 2x8 with AC 208-240V power supply, use a power supply cord that matches and is properly rated for the AC power outlet being used. The power sup­ply cord you use must have been approved by and comply with the safety standards of your coun­try.
The inside of the fluorescent tubes located within the LCD monitor contains mercury. Please follow the bylaws or rules of your municipality to dispose of the tube properly.
AFETY WARNINGS AND CAUTIONS
Epicenter, Inc.
Page 6
P
RODUCT FEATURES
Epicenter, Inc.
Page 7
R
ACK MOUNT INSTALLATION
FOR INSTALLATION YOU WILL NEED THE FOLLOWING:
Centerpoint 2x8 or 2x16 Product
Power cord
Rails with hardware
User Guide
Epicenter KVM Cables for connecting video, keyboard, and mouse
STANDARD 1U INSTALLATION
Use the following procedure to install Centerpoint 2x8 or 2x16 in the rack.
Centerpoint 2x8 and 2x16 are shipped with the side-mount rails already installed on the unit.
Insert a rack-mounting bracket into the rack at a level that will be comfortable for operating the keyboard, mouse and viewing the monitor. Align the screw holes at the front and back of the rack on both side rails. Use one screw to at­tach the mounting bracket to the front of the rack and two screws to attach the slide to the rear of the rack.
Once the rack mounts are in place you can now place the Cen­terpoint 2x8 or 2x16 unit in the rack.
Leave the upper screen panel closed as you guide the rack­mount slides into the rails mounted upon the rack. Once the system is in place depress the retaining but­tons and slide the unit com­pletely into the rack. Secure the outer slides in place with the included retention screws.
Warning!
To reduce the risk of personal injury or damage to the equip­ment, be sure that the following items are completed BEFORE performing any work on the rack:
The leveling jacks are extended to the floor.
The full weight of the rack rests on the leveling jacks.
The stabilizing feet are attached to the rack, if it is a single-rack installation.
The racks are coupled in multiple-rack installations.
Important
When mounting the rack slides
make sure that the end of the slides
with the extension brackets are installed to the rear of the rack.
Warning!
The Centerpoint products weigh in excess of 30 pounds and can be awkward to handle. Handle the product carefully and use sen­sible lifting procedures.
Take care to insure that the internal slide unit does not extend during transportation causing the unit to become unwieldy.