EPH Elektronik DLS 24/ 10, DLS 24/ 20 User guide

Assembly instruction / User manual
1-Q motor speed control unit digital, type DLS 24/xx-460
Technical data under reserve technical changes
Please read these instruction before using and please keep safe for future. You may download further technical advice under www.eph-elektronik.de.
Seite 1 von 8 Stand: August 2018 Z314-MG
Table of contents
1. Safety Instructions and Safeguarding ......................................................................... 3
1.1. Installation note................................................................................................... 3
1.2. ESD-Protection / Hazard note............................................................................. 3
2. Getting started DLS24/xx-460 with 6/4-pole spring clamp terminal ............................. 4
3. Technical features ....................................................................................................... 5
4. Technical data ............................................................................................................. 5
5. Connecting .................................................................................................................. 6
5.1. Control connection .............................................................................................. 7
5.2. Connecting diagram ............................................................................................ 7
6. CE Declaration of Conformity ...................................................................................... 8
Seite 2 von 8 Stand: August 2018 Z314-MG
Attention during
Danger to burn
-
Danger to fire
-
1. Safety Instructions and Safeguarding
1.1. Installation note
An external mains adapter is required for the electrical supply of the controller EPH 460. If this mains adapter is itself supplied with a voltage >50V DC or >75V AC the following points have to be considered: The unit should only be installed by qualified specialist personnel. Installation and operation of the unit should comply with the local regulations for electrical installations as well as health and safety regulations. The protection of people and property must be warranted by applying the currently applicable safety regulations (VDE, electrical safety regulations, IEC, etc.). High start-up currents can occur at the moment of tuning on a controller device / mains adapter due to charging process of the intermediate circuit. An effective safeguard is therefore required on the mains input side (e.g. a C-Rated 16A line circuit breaker). The use of RCD circuit breakers before control unit / mains adapter is not recommended because of the leakage currents generated by EMC interference suppressing devices. The regulator card / mains adapter must not be operated without an effective connection to earth! The connection to earth must comply with local regulations.
1.2. ESD-Protection / Hazard note
installation of the electronic board!
It must be warranted on your part that there is sufficient ESD-protection.
Seite 3 von 8 Stand: August 2018 Z314-MG
Parts of this controller card can be reach a temperature up to 80°C. Increased risk at controller cards without protective cover.
Beware!
Beware!
Unprofessional handling and installation can cause a fire.
Danger to life-Beware!
Parts of this controller card are under intermediate circuit voltage and remain energised >50VAC respectively 75VDC after turning main power off. Coming into contact with the terminals, lines and unit parts can cause serious injuries or result in death!