Page 1 of 2
R27 - 2 Zone Programmer
Installation Instructions
For use in normal environments.
CAUTION! Installation and connection should only be carried out by a qualied
person and in accordance with national wiring regulations.
Before commencing any work on the electrical connections, you must rst disconnect the programmer
from the mains. None of the 230V connections must be live until the installation has been completed
and the housing is closed. Only qualied electricians or authorised service sta are permitted to open
the programmer. Disconnect from mains supply in the event of any damage to any buttons.
There are parts that carry mains voltage behind the cover. The programmer must not be left
unsupervised when open. (Prevent non specialists and especially children from gaining access to it.)
If the programmer is used in a way not specied by the manufacturer, its safety may be impaired.
Prior to setting the timeswitch, it is neccessary to complete all required settings described in this section.
Never remove this product from the electrical baseplate. Do not use sharp tools to push any button.
This programmer can be mounted in the following ways: 1. Directly wall mounted 2. Mounted to a recessed conduit box
1
2
This 2 zone programmer is designed to provide
ON/OFF control for 2 zones, with the value added
application of in built frost protection.
Impor tant: Kee p this document
Type
1C
EN60730
100
160.5
°C
50
122
°F
32
0
3
IP20
EN60529
5-95%RH
4
5 6
EPH Controls Ireland
sales@ephcontrols.com www.ephcontrols.com
EPH Controls UK
sales@ephcontrols.co.uk www.ephcontrols.co.uk
20180621_R27_InsIns_JW
Page 2 of 2
R27 - 2 Zone Programmer
Contents
1. Factory default settings
2. Specications & wiring
3. Master reset
1. Factory default settings
Contacts: 230 Volt
Program: 5/2D
Backlight: On
Keypad: Unlocked
Frost Protection: O
Clock type: 24 Hr Clock
Day-Light Saving
2. Specications & wiring
Power Supply: 230 Vac
Ambient Temp: 0~35°C
Contact Rating: 250 Vac 3A(1A)
Program Memory
backup: 1 year
Battery: 3Vdc Lithium LIR 2032
Backlight: Blue
IP rating: IP20
Backplate: British System Standard
Pollution degree 2: Resistance to voltage surge 2000V
as per EN 60730
Automatic Action: Type 1.C
Software: Class A
Installation Instructions
For use in normal environments.
Z1
ON
Z2
ON
200-240Vac
50Hz-60Hz
Z1
OFFZ2OFF
CONTACT RATING: 250Vac~/3(1)A
3. Master reset
Lower the cover on the front of the programmer. There are four hinges
holding the cover in place.
Between the 3rd and 4th hinges there is a circular hole. Insert a ball point
pen or similar object to master reset the programmer.
After pressing the master reset button, the date and time will now need to
be reprogrammed.
EPH Controls Ireland
sales@ephcontrols.com www.ephcontrols.com
EPH Controls UK
sales@ephcontrols.co.uk www.ephcontrols.co.uk
20180621_R27_InsIns_JW