Eph controls R27 User Manual

Page 1 of 2
R27 - 2 Zone Programmer
Installation Instructions
For use in normal environments.
CAUTION! Installation and connection should only be carried out by a qualied
person and in accordance with national wiring regulations.
Before commencing any work on the electrical connections, you must rst disconnect the programmer
from the mains. None of the 230V connections must be live until the installation has been completed and the housing is closed. Only qualied electricians or authorised service sta are permitted to open the programmer. Disconnect from mains supply in the event of any damage to any buttons.
There are parts that carry mains voltage behind the cover. The programmer must not be left
unsupervised when open. (Prevent non specialists and especially children from gaining access to it.)
If the programmer is used in a way not specied by the manufacturer, its safety may be impaired.
Prior to setting the timeswitch, it is neccessary to complete all required settings described in this section.
Never remove this product from the electrical baseplate. Do not use sharp tools to push any button.
This programmer can be mounted in the following ways: 1. Directly wall mounted 2. Mounted to a recessed conduit box
1
2
This 2 zone programmer is designed to provide ON/OFF control for 2 zones, with the value added application of in built frost protection.
Impor tant: Kee p this document
Type
1C
EN60730
100
160.5
°C
50
122
°F
32
0
3
IP20
EN60529
5-95%RH
4
5 6
EPH Controls Ireland
sales@ephcontrols.com www.ephcontrols.com
EPH Controls UK
sales@ephcontrols.co.uk www.ephcontrols.co.uk
20180621_R27_InsIns_JW
Page 2 of 2
R27 - 2 Zone Programmer
Contents
1. Factory default settings
2. Specications & wiring
3. Master reset
1. Factory default settings
Contacts: 230 Volt Program: 5/2D Backlight: On Keypad: Unlocked Frost Protection: O Clock type: 24 Hr Clock Day-Light Saving
2. Specications & wiring
Power Supply: 230 Vac Ambient Temp: 0~35°C Contact Rating: 250 Vac 3A(1A) Program Memory backup: 1 year Battery: 3Vdc Lithium LIR 2032 Backlight: Blue IP rating: IP20 Backplate: British System Standard Pollution degree 2: Resistance to voltage surge 2000V as per EN 60730 Automatic Action: Type 1.C Software: Class A
Installation Instructions
For use in normal environments.
Z1
ON
Z2
ON
200-240Vac
50Hz-60Hz
Z1
OFFZ2OFF
CONTACT RATING: 250Vac~/3(1)A
3. Master reset
Lower the cover on the front of the programmer. There are four hinges holding the cover in place.
Between the 3rd and 4th hinges there is a circular hole. Insert a ball point pen or similar object to master reset the programmer.
After pressing the master reset button, the date and time will now need to be reprogrammed.
EPH Controls Ireland
sales@ephcontrols.com www.ephcontrols.com
EPH Controls UK
sales@ephcontrols.co.uk www.ephcontrols.co.uk
20180621_R27_InsIns_JW