![](/html/6b/6bb2/6bb2de928f24568f11aeb0e37e0b734cdbc52b44051878b65522da5db8b4e2fc/bg1.png)
Page 1 of 2
R17 - 1 Zone Timeswitch
Contents
1. Factory default settings
2. Factory program settings
3. Resetting the timeswitch
4. Setting the date and time
5. ON/OFF period selection
6. Adjusting the program settings
7. Copy function
8. Reviewing the program settings
9. Boost function
10. Advance function
11. Holiday mode
12. Backlight mode selection
13. Keypad lock and unlock
14. Frost protection
15. Master reset
1. Factory default settings
Program: 5/2D
Backlight: On
Keypad: Unlocked
Frost Protection: O
2. Factory program settings
Mon-Fri
Sat-Sun
All 7 days
Everyday
P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF
6:30
7:30 10:00 12:00 12:00 17:00 23:00
P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF
6:30
P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF
6:30
8:30
8:30
8:30
12:00
12:00
12:00
5/2D
12:00
7D
12:00
24H
12:00
3. Resetting the timeswitch
It is necessary to press the RESET button prior to initial programming.
This button is located behind the cover on the front of the unit.
Impor tant: Kee p this document
This 1 zone timeswitch is designed to
provide ON/OFF control for 1 zone, with
the value added application of in built
frost protection.
16:30
16:30
16:30
22:30
22:30
22:30
Operating Instructions
CAUTION!
Before commencing, disconnect the
device from the mains. There are parts that
carry mains voltage behind the cover. Never
leave unsupervised when it is open. (Prevent
non specialists and especially children from
gaining access to it.)
Never remove this product from the
electrical baseplate. Disconnect from mains
supply in the event of any damage to any
buttons. Do not use sharp tools to push any
button.
5. ON/OFF period selection
There are 4 modes available on this timeswitch for users to choose for their
individual application.
AUTO The timeswitch operates 3 ‘ON/OFF’ periods per day.
ALL DAY The timeswitch operates 1’ON/OFF’ period per day.
This operates from the rst ON time to the third OFF time.
ON The timeswitch is permanently on. **ON**
OFF The timeswitch is permanently o. **OFF**
Lower the cover on the front of the unit. By pressing the button,
you can change between AUTO / ALL DAY / ON / OFF for Zone 1.
6. Adjusting the program settings
Lower the cover on the front of the unit.
Move the selector switch to the PROG SET position.
You can now program zone 1.
Press the or buttons to adjust the P1 ON time.
Press the or buttons to adjust the P1 OFF time.
Repeat this process to adjust the ON & OFF times for P2 & P3.
When completed, move the selector switch to the RUN position.
7. Copy function
CLOCK
SET
RUN
Press
Press
PROG
SET
RUN
4. Setting the date and time
CLOCK
SET
Lower the cover on the front of the unit.
Move the selector switch to the CLOCK SET position.
Press the or buttons to select the day.
Press the or buttons to select the month.
Press the or buttons to select the year.
Press the or buttons to select the hour.
Press the or buttons to select the minute.
Press the or buttons to select 5/2D, 7D or 24H
Press
Press
Press
Press
Press
Press
The date, time and function are now set. Move the selector switch to the
RUN position to run the program, or to the PROG SET position to change
the program setting.
EPH Controls Ireland
Sitecast Industrial Estate, Pouladu,
Cork, T12 W665, Ireland
sales@ephcontrols.com www.ephcontrols.com
PROG
SET
Copy function may only be used if the timeswitch is in the 7d mode.
Lower the cover on the front of the timeswitch.
Move the selector switch to the PROG SET position.
CLOCK
SET
RUN
PROG
SET
Set the ON & OFF times for the day of the week you wish to copy from.
COPY
Press button for 2 seconds. The next day of the week will begin to
Holiday
ash.
Press the button to copy the ON & OFF times to this day.
Press the button to skip a day.
ON & OFF times can be copied to muliple days by using the button.
Press the button when copying has been completed.
When completed, move the selector switch to the RUN position.
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
sales@ephcontrols.co.uk www.ephcontrols.co.uk
20170310_AW1077_R17_OpIns_JW
![](/html/6b/6bb2/6bb2de928f24568f11aeb0e37e0b734cdbc52b44051878b65522da5db8b4e2fc/bg2.png)
Page 2 of 2
R17 - 1 Zone Timeswitch
8. Reviewing the program settings
ZONE
ADV.
1
CLOCK
SET
CLOCK
SET
RUN
Lower the cover on the front of the unit.
Move the selector switch to the PROG SET position.
By pressing this will review each of the ON/OFF times for P1 to P3.
When completed, move the selector switch to the RUN position.
9. Boost function
This function allows the user to extend the ON period for 1, 2 or 3 hours.
If the zone that you wish to Boost is timed to be OFF, you have the
facility to switch it ON for 1, 2 or 3 hours.
ZONE
1
Press once, twice or three times respectively.
Boost
To cancel the boost function, simply press the button again.
ZONE
Boost
1
10. Advance function
This function allows the user to bring forward the next switching time. If the
zone is currently timed to be OFF and the ADV is pressed, the zone will be
switched ON until the end of the next switching time. If the zone is currently
timed to be ON and the ADV is pressed, the zone will be switched OFF until
the end of the next switching time.
ZONE
1
Press for this function.
ADV.
To cancel the ADVANCE function, simply press the button again.
11. Holiday mode
Lower the cover on the front of the unit.
Move the selector switch to the RUN position.
Press the button.
The current date and time will ash on the creen.
It is now possible to enter the date and time when you plan to return.
Press the or buttons to adjust the holiday period required.
Press the button.
The timeswitch is now switched OFF for the selected number of days.
By pressing the button again, this will cancel the holiday mode,
thereby returning the timeswitch to the normal setting.
12. Backlight mode selection
Holiday
On
RUN
PROG
SET
13. Keypad lock and unlock
PROG
SET
To lock the keypad, press and hold the and buttons for
5 seconds.
will appear on the screen. The keypad is now locked.
To unlock the keypad, press and hold the and buttons for
5 seconds.
will disappear from the screen. The keypad is now unlocked.
14. Frost protection function
Selectable range 5~20°C. This function is set to protect pipes against
freezing or to prevent low room temperature when the timeswitch is
programmed to be OFF or is manually OFF.
Frost protection can be activated by following the procedure below.
Move the selector switch to the RUN position.
Press both the and buttons for 5 seconds, to enter selection mode.
Press either the or buttons to to turn On or turn O frost
protection.
Press the button to conrm.
Press either the or buttons to increase or decrease the desired
frost protection setpoint.
Press the button to select.
Zone 1 will be switched ON in the event of room temperature falling below
the frost protection setpoint.
When frost protection is enabled, “Frost” will be visible on the screen.
When frost protection is activated, “Frost” will ash on the screen.
15. Master reset
Lower the cover on the front of the timeswitch.
There are four hinges holding the cover in place.
Between the 3rd and 4th hinges there is a circular hole.
Insert a ball point pen or similar object to master reset the timeswitch.
After pressing the master reset button, the date and time will now need
to be reprogrammed.
Operating Instructions
Unlocked
Holiday
Holiday
O
RUN
CLOCK
SET
PROG
SET
There are two settings for selection. The factory default setting is ON.
ON The backlight is permanently ON.
AUTO On pressing any button the backlight stays on for 10 seconds.
To adjust the backlight setting, lower the cover on the front of the unit.
RUN
Move the selector switch to the RUN position.
Press the button for 5 seconds.
CLOCK
SET
PROG
Press either the or buttons to select the ON or AUTO mode.
Press the button.
EPH Controls Ireland
Sitecast Industrial Estate, Pouladu,
Cork, T12 W665, Ireland
sales@ephcontrols.com www.ephcontrols.com
SET
20170310_AW1077_R17_OpIns_JW
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom