Epcos B 84142 – B 8 – R Service Manual

www.DataSheet4U.com
2-Line Filters B84142-B*-R
for Converters and Power Electronics
Power line filters for single-phase systems Rated voltage 250 V~, 50/60 Hz Rated current 8 A to 25 A
Two-line filter
Metal case
Features
Very high insertion loss
due to two-stage construction
Low leakage current
Easy to install
Degree of protection: IP 20
Design complies with
1)
EN 133 200, UL 1283, CSA 22.2 No.8 1986
Optimized for long motor cables
and operation under full load
Applications
Frequency converters for motor drives, e.g.
elevatorsconveyor systemspumpstraction systemsHVAC systems (heating, ventilation and air conditioning)
Power supplies
Terminals
Safe-to-touch terminal blocks
Marking
Marking on component: Manufacturers logo, ordering code, rated voltage, rated current, rated temperature, date code
Minimum marking on packaging: Manufacturers logo, ordering code
1) In accordance with IEC 60529: 1989; EN 60529: 1991; DIN VDE 0470-1
179 03/01
2-Line Filters B84142-B*-R
for Converters and Power Electronics
Typical circuit diagram
LINE
L
N
Technical data
Rated voltage V Rated current I Test voltage V
R
R
P
250 V~, 50/60 Hz Referred to 40 °C ambient temperature 1770 V–, 2 s (line/line)
2700 V–, 2 s (lines/case)
Overload capability 1,5 · I
Leakage current I
at 250 V~, 50 Hz
leak
for 3 min per hour or
R
2,5 · I
for 30 s per hour
R
Climatic category 25/100/21 (– 25
in accordance with EN 60068-1
LOAD
L
N
SSB0772-K
°C/+ 100 °C/21 days damp heat test)
Characteristics and ordering codes
I
R
A 8 4 12 4 16 4 25 10
Terminal cross section
2
mm
I
leak
mA
< 3,5 42 1,35 B84142-B8-R < 3,5 30 1,45 B84142-B12-R < 3,5 21 1,45 B84142-B16-R < 3,5 9 3,7 B84142-B25-R
R
typ
m
180 03/01
Approx. weight kg
Ordering code