Customer-Specific Filters B84132-MBS
for Base Stations
Power line filters for base stations
Rated voltage 250 V–/ 250 V~, 50/60 Hz
Rated current 16 to 80 A
Construction
■ Two-line filter
■ Metal case
Features
■ Easy to install
■ Space-saving design
■ High insertion loss up to GHz range
■ Design complies with
EN 133200, CSA 22.2 No. 8 1986
■ Filter for 50 A: UL 1283 approval
■ Optimized for use under high climatic stress
Applications
■ Base stations
■ Power supplies
Terminals
■ Line: Litz wires
■ Load: Threaded studs
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated current, rated voltage,
rated temperature, date code,
terminal assignment, safety approvals
Minimum marking on packaging:
Manufacturer’s logo, ordering code
316 03/01

Customer-Specific Filters B84132-MBS
for Base Stations
Circuit diagram
LINE LOAD
1
1’
2
2’
SSB1636-N
Technical data
Rated voltage V
Rated current I
Test voltage V
R
R
P
250 V−/250 V~, 50/60 Hz
referred to 60 °C ambient temperature
1700 V– , 2 s (line/line)
1700 V– , 2 s (lines/case)
Overload capability 1,5 · I
Leakage current I
leak
Climatic category 25/100/21 (– 25
for 3 min per hour or
R
2,5 · I
für 30 s per hour
R
at 250 V~, 50 Hz
°C/+100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
I
R
A
Terminal
cross section
2
mm
I
leak
mA
R
mΩ
typ
Approx.
weight
kg
Ordering code
16 4 17 4,8 0,8 upon request
25 4 17 2,9 1,0
50 8,35 17 0,8 1,2
80 25 17 0,7 1,8
317 03/01