Epcos B 84132 MBS Service Manual

www.DataSheet4U.com
Customer-Specific Filters B84132-MBS
for Base Stations
Power line filters for base stations Rated voltage 250 V–/ 250 V~, 50/60 Hz Rated current 16 to 80 A
Two-line filter
Metal case
Features
Easy to install
Space-saving design
High insertion loss up to GHz range
Design complies with
EN 133200, CSA 22.2 No. 8 1986
Filter for 50 A: UL 1283 approval
Optimized for use under high climatic stress
Applications
Base stations
Power supplies
Terminals
Line: Litz wires
Load: Threaded studs
Marking
Marking on component: Manufacturers logo, ordering code, rated current, rated voltage, rated temperature, date code, terminal assignment, safety approvals
Minimum marking on packaging: Manufacturers logo, ordering code
316 03/01
Customer-Specific Filters B84132-MBS
for Base Stations
Circuit diagram
LINE LOAD
1
1
2
2
SSB1636-N
Technical data
Rated voltage V Rated current I Test voltage V
R
R
P
250 V/250 V~, 50/60 Hz referred to 60 °C ambient temperature 1700 V– , 2 s (line/line)
1700 V– , 2 s (lines/case)
Overload capability 1,5 · I
Leakage current I
leak
Climatic category 25/100/21 (– 25
for 3 min per hour or
R
2,5 · I
für 30 s per hour
R
at 250 V~, 50 Hz
°C/+100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
I
R
A
Terminal cross section
2
mm
I
leak
mA
R
m
typ
Approx. weight kg
Ordering code
16 4 17 4,8 0,8 upon request 25 4 17 2,9 1,0 50 8,35 17 0,8 1,2 80 25 17 0,7 1,8
317 03/01
Loading...
+ 3 hidden pages