Epcos B 84101 Service Manual

www.DataSheet4U.com
4-Line Filters B84108
for Installations and Systems
Power line filters for three-phase systems Rated voltage 440/250 V~, 50/60 Hz Rated current 10 and 20 A
Four-line filter
Metal case
Features
Medium insertion loss
Small size (similar to SIFI)
Easy to install
Applications
Industrial electronics
Medical engineering
Elevators
Terminals
Tab connectors 6,3 × 0,8 mm
Marking
Marking on component: Manufacturers logo, ordering code, rated voltage, rated current, date code
Minimum marking on packaging: Manufacturers logo, ordering code
Circuit diagram
LINE
L1
L2
L3
N
LOAD
L1
L2
L3
N
SSB0334-1
292 03/01
4-Line Filters B84108
for Installations and Systems
Technical data
Rated voltage V Rated current I Test voltage V
R
R
P
440/250 V~, 50/60 Hz referred to 40 °C ambient temperature 1414 V–, 2 s (line/line)
2700 –, 2 s (lines/case)
Leakage current l
leak
at 400 V~, 50 Hz
Climatic category in accordance with EN 60068-1
25/085/21 (– 25
°C/+ 85 °C/21 days damp heat test)
Weight approx. 220 g
Characteristics and ordering codes
I
A 10
20
R
l
leak
mA < 3,5
< 3,5
Ordering code Approvals
B84108-S1004-A110 B84108-S1004-A120
× = approval granted
Dimensional drawing
84,5
15 14
74,5
565-3
×
50,8
31,5
4,7
Flachstecker
Tab connector A6,3 × 0,8
A6,3 x 0,8 DIN 46244
DIN 46244
38+0,8
63,5 89,5
SSB0335-R
293 03/01