Epcos B 82503 Service Manual

www.DataSheet4U.com
I Core Chokes
Rated voltage 400 Vac/450 Vdc Rated current 0,5 to 10 A Rated inductance 0,1 to 47 mH
Construction
Chokes with winding of enamel copper wire
Low power dissipation
Broadband interference suppression
Applications
Attenuation of differential
and common-mode interference
High-performance power supplies
Industrial applications
Terminals
Tab connectors
Marking
Manufacturer, ordering code, rated inductance, rated current, VDE mark
Approvals
Approval mark Standard
VDE 0565-2
B82503Chokes for Power Lines
Dimensional drawing
311 04/00
B82503Chokes for Power Lines
I Core Chokes
General technical data
Inductance tolerance ± 20 % Rated current DC resistance
I
R
R
typ
Referred to 50 Hz and 40 °C ambient temperature Typical value, measured at 20 °C ambient temperature
Climatic category 40/125/56 (– 40 °C/+ 125 °C/56 days damp heat test)
in accordance with IEC 60068-1
Permissible operating current at 400 Hz 0,75 ·
I
R
Weight Approx. 70 to 90 g For further technical data see page 308
Characteristics and ordering codes
I
R
A
L
mH
R
R
typ
Ordering code
0,5 47 10 B82503-U-A5 1 15 2,7 B82503-U-A8 2 3,3 0,7 B82503-U-A10 4 0,68 0,2 B82503-U-A12 6 0,33 0,1 B82503-U-A13
10 0,1 0,03 B82503-U-A14
Impedance |Z|
versus frequency
f
312 04/00