查询B57891S0103F008供应商
NTC thermistors for
temperature measurement
Leaded NTCs,
lead spacing 2.5 mm
Series/Type: B57891
Date: March 2006
© EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained thereinwithout EPCOS' prior express consent is prohibited.
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
Applications
Dimensional drawing
Heating systems
Automotive electronics
Features
Favorable price/ performance ratio
Rugged design, epoxy resin encapsulation
Leads: copper-clad Fe wire, tinned
UL approval (E69802)
Options
Lead spacing 5 mm available on request
Delivery mode
Bulk (standard),
cardboard tape, reeled or in Ammo pack
Dimensions in mm
Approx. weight 0.2 g
General technical data
Climatic category (IEC 60068-1) 55/155/56
Max. power (at 25 ° C) P
200 mW
25
Resistance tolerance ∆ RR/RR±1, ±3, ±5 %
Rated temperature T
Dissipation factor (in air) δ
Thermal cooling time constant (in air) τ
Heat capacity C
th
c
25 ° C
R
approx. 4 mW/K
approx. 15 s
approx. 60 mJ/K
th
Electrical specification and ordering codes
R
25
Ω
No. of R/T
characteristic
B
K
25/100
Ordering code
2.2 k 1008 3560 ± 1.5% B57891S0222+008
5 k
10 k
20 k
100 k
+ = Resistance tolerance
F = ± 1%
H = ± 3%
J = ± 5%
Cautions and warnings at the end of this document.
2003 3980 ± 1.0% B57891S0502+008
4901 3950 ± 1.0% B57891S0103+008
2904 4300 ± 1.0% B57891S0203+008
4003 4450 ± 1.0% B57891S0104+008
Page 2 of 25Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
Reliability data
Test Standard Test conditions ∆ R25/R
(typical)
Storage in
dry heat
IEC
60068-2-2
Storage at upper
category temperature
< 3% No visible
T: 155 ° C
t: 1000 h
Storage in damp
heat, steady state
IEC
60068-2-78
Temperature of air: 40 ° C
Relative humidity of air: 93%
< 1% No visible
Duration: 56 days
Rapid temperature
cycling
IEC
60068-2-14
Lower test temperature: 55 ° C
Upper test temperature: 155 ° C
< 2% No visible
Number of cycles: 100
Endurance P
: 200 mW
max
< 3% No visible
t: 1000 h
Long-term stability
(empirical value)
Temperature: 70 ° C
t: 10000 h
< 3% No visible
Remarks
25
damage
damage
damage
damage
damage
Cautions and warnings at the end of this document.
Page 3 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
R/T characteristics
B57891S0222F008
R/T No. 1008
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
= 3560 K, R25= 2200 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
116830 107930
86499 80383
64515 60293
48466 45537
36666 34627
27931 26506
21395 20398
16538 15837
12838 12346
10051 9706
7931 7689
6306 6137
5040 4922
4056 3975
3282 3228
2674 2638
2200 2178
1825 1801
1510 1485
1256 1232
1056 1033
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
125730
92614
68738
51395
38706
29356
22392
17238
13329
10396
8173
6476
5157
4137
3337
2710
2222
1850
1535
1280
1079
7.6 1.2 6.1
7.1 1.2 6.0
6.5 1.1 5.8
6.0 1.1 5.7
5.6 1.0 5.5
5.1 0.9 5.4
4.7 0.9 5.2
4.2 0.8 5.1
3.8 0.8 4.9
3.4 0.7 4.8
3.1 0.7 4.7
2.7 0.6 4.5
2.3 0.5 4.4
2.0 0.5 4.3
1.7 0.4 4.1
1.4 0.3 4.0
1.0 0.3 3.9
1.3 0.4 3.8
1.6 0.4 3.7
1.9 0.5 3.6
2.2 0.6 3.5
50.0 892.0 870.3 913.7 2.4 0.7 3.4
55.0 751.7 731.5 771.9 2.7 0.8 3.3
60.0 636.9 618.3 655.6 2.9 0.9 3.2
65.0 543.7 526.5 560.9 3.2 1.0 3.1
70.0 466.0 450.2 481.9 3.4 1.1 3.1
75.0 400.3 385.8 414.8 3.6 1.2 3.0
80.0 345.0 331.7 358.2 3.8 1.3 2.9
85.0 299.0 286.9 311.1 4.1 1.4 2.8
90.0 260.1 249.0 271.2 4.3 1.5 2.8
95.0 227.5 217.3 237.6 4.5 1.7 2.7
100.0 199.6 190.3 208.9 4.6 1.8 2.6
105.0 175.2 166.7 183.7 4.8 1.9 2.6
110.0 154.2 146.5 162.0 5.0 2.0 2.5
115.0 136.2 129.1 143.2 5.2 2.1 2.4
120.0 120.5 114.0 127.0 5.4 2.3 2.4
125.0 107.2 101.2 113.1 5.5 2.4 2.3
130.0 95.51 90.05 101.0 5.7 2.5 2.3
135.0 85.19 80.18 90.19 5.9 2.6 2.2
Cautions and warnings at the end of this document.
Page 4 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0222F008
R/T No. 1008
T (° C) B
= 3560 K, R25= 2200 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
140.0 76.15 71.56 80.75 6.0 2.8 2.2
145.0 68.31 64.08 72.53 6.2 2.9 2.1
150.0 61.40 57.51 65.29 6.3 3.0 2.1
155.0 55.42 51.83 59.02 6.5 3.2 2.0
B57891S0222H008
R/T No. 1008
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
= 3560 K, R25= 2200 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
116830 105590
86499 78653
64515 59002
48466 44568
36666 33893
27931 25947
21395 19971
16538 15507
12838 12090
10051 9505
7931 7530
6306 6011
5040 4821
4056 3894
3282 3162
2674 2584
2200 2134
1825 1764
1510 1455
1256 1207
1056 1012
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
128060
94344
70028
52364
39439
29914
22820
17568
13585
10597
8332
6602
5258
4218
3403
2764
2266
1887
1565
1305
1100
9.6 1.6 6.1
9.1 1.5 6.0
8.5 1.5 5.8
8.0 1.4 5.7
7.6 1.4 5.5
7.1 1.3 5.4
6.7 1.3 5.2
6.2 1.2 5.1
5.8 1.2 4.9
5.4 1.1 4.8
5.1 1.1 4.7
4.7 1.0 4.5
4.3 1.0 4.4
4.0 0.9 4.3
3.7 0.9 4.1
3.4 0.8 4.0
3.0 0.8 3.9
3.3 0.9 3.8
3.6 1.0 3.7
3.9 1.1 3.6
4.2 1.2 3.5
50.0 892.0 852.4 931.5 4.4 1.3 3.4
55.0 751.7 716.5 787.0 4.7 1.4 3.3
60.0 636.9 605.5 668.3 4.9 1.5 3.2
65.0 543.7 515.6 571.8 5.2 1.6 3.1
70.0 466.0 440.9 491.2 5.4 1.8 3.1
75.0 400.3 377.8 422.8 5.6 1.9 3.0
80.0 345.0 324.8 365.1 5.8 2.0 2.9
85.0 299.0 280.9 317.1 6.1 2.1 2.8
90.0 260.1 243.8 276.4 6.3 2.3 2.8
Cautions and warnings at the end of this document.
Page 5 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0222H008
R/T No. 1008
T (° C) B
= 3560 K, R25= 2200 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
95.0 227.5 212.8 242.2 6.5 2.4 2.7
100.0 199.6 186.4 212.9 6.6 2.5 2.6
105.0 175.2 163.2 187.2 6.8 2.7 2.6
110.0 154.2 143.4 165.1 7.0 2.8 2.5
115.0 136.2 126.3 146.0 7.2 2.9 2.4
120.0 120.5 111.6 129.4 7.4 3.1 2.4
125.0 107.2 99.06 115.2 7.5 3.2 2.3
130.0 95.51 88.14 102.9 7.7 3.4 2.3
135.0 85.19 78.48 91.90 7.9 3.5 2.2
140.0 76.15 70.03 82.27 8.0 3.7 2.2
145.0 68.31 62.71 73.90 8.2 3.8 2.1
150.0 61.40 56.28 66.52 8.3 4.0 2.1
155.0 55.42 50.72 60.13 8.5 4.2 2.0
B57891S0222J008
R/T No. 1008
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
= 3560 K, R25= 2200 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
116830 103260
86499 76924
64515 57712
48466 43598
36666 33160
27931 25389
21395 19543
16538 15176
12838 11833
10051 9304
7931 7372
6306 5884
5040 4720
4056 3813
3282 3096
2674 2531
2200 2090
1825 1728
1510 1425
1256 1182
1056
[Ω ] R
min
991.1
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
130400
96074
71319
53334
40172
30473
23248
17899
13842
10798
8490
6728
5359
4300
3469
2817
2310
1923
1595
1330
1122
11.6 1.9 6.1
11.1 1.9 6.0
10.5 1.8 5.8
10.0 1.8 5.7
9.6 1.7 5.5
9.1 1.7 5.4
8.7 1.7 5.2
8.2 1.6 5.1
7.8 1.6 4.9
7.4 1.5 4.8
7.1 1.5 4.7
6.7 1.5 4.5
6.3 1.4 4.4
6.0 1.4 4.3
5.7 1.4 4.1
5.4 1.3 4.0
5.0 1.3 3.9
5.3 1.4 3.8
5.6 1.5 3.7
5.9 1.6 3.6
6.2 1.8 3.5
Cautions and warnings at the end of this document.
Page 6 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0222J008
R/T No. 1008
T (° C) B
= 3560 K, R25= 2200 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
50.0 892.0 834.6 949.4 6.4 1.9 3.4
55.0 751.7 701.5 802.0 6.7 2.0 3.3
60.0 636.9 592.8 681.1 6.9 2.1 3.2
65.0 543.7 504.7 582.7 7.2 2.3 3.1
70.0 466.0 431.5 500.5 7.4 2.4 3.1
75.0 400.3 369.8 430.8 7.6 2.6 3.0
80.0 345.0 317.9 372.0 7.8 2.7 2.9
85.0 299.0 274.9 323.1 8.1 2.8 2.8
90.0 260.1 238.6 281.6 8.3 3.0 2.8
95.0 227.5 208.2 246.7 8.5 3.1 2.7
100.0 199.6 182.4 216.9 8.6 3.3 2.6
105.0 175.2 159.7 190.7 8.8 3.4 2.6
110.0 154.2 140.3 168.1 9.0 3.6 2.5
115.0 136.2 123.6 148.7 9.2 3.8 2.4
120.0 120.5 109.2 131.8 9.4 3.9 2.4
125.0 107.2 96.92 117.4 9.5 4.1 2.3
130.0 95.51 86.23 104.8 9.7 4.3 2.3
135.0 85.19 76.77 93.60 9.9 4.4 2.2
140.0 76.15 68.51 83.80 10.0 4.6 2.2
145.0 68.31 61.35 75.27 10.2 4.8 2.1
150.0 61.40 55.05 67.75 10.3 5.0 2.1
155.0 55.42 49.61 61.24 10.5 5.1 2.0
B57891S0502F008
R/T No. 2003
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
Cautions and warnings at the end of this document.
= 3980 K, R25= 5000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
[Ω ] R
min
487890 458880
338250 319530
237690 225460
169160 161090
121800 116420
88766 85153
65333 62889
48614 46950
36503 35365
27680 26898
21166 20628
16330 15959
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
516900
356980
249920
177230
127170
92378
67776
50278
37641
28463
21704
16701
Page 7 of 25Please read Important notes and
5.9 0.8 7.4
5.5 0.8 7.2
5.1 0.7 6.9
4.8 0.7 6.7
4.4 0.7 6.5
4.1 0.7 6.2
3.7 0.6 6.0
3.4 0.6 5.8
3.1 0.6 5.6
2.8 0.5 5.5
2.5 0.5 5.3
2.3 0.4 5.1
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0502F008
R/T No. 2003
T (° C) B
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
= 3980 K, R25= 5000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
12696 12441
9951 9776
7855 7736
6246 6166
5000 4950
4029 3978
3266 3218
2665 2619
2186 2144
1803 1766
1495 1461
1247 1216
1044 1017
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
12951
10126
7974
6326
5050
4080
3315
2710
2227
1841
1529
1277
1072
2.0 0.4 5.0
1.8 0.4 4.8
1.5 0.3 4.7
1.3 0.3 4.5
1.0 0.2 4.4
1.3 0.3 4.3
1.5 0.4 4.1
1.7 0.4 4.0
1.9 0.5 3.9
2.1 0.5 3.8
2.3 0.6 3.7
2.5 0.7 3.6
2.6 0.8 3.5
70.0 878.9 854.3 903.5 2.8 0.8 3.4
75.0 743.1 721.1 765.2 3.0 0.9 3.3
80.0 631.0 611.3 650.8 3.1 1.0 3.2
85.0 538.2 520.5 555.9 3.3 1.0 3.1
90.0 460.8 444.9 476.6 3.4 1.1 3.1
95.0 396.1 381.9 410.3 3.6 1.2 3.0
100.0 341.8 329.0 354.5 3.7 1.3 2.9
105.0 296.2 284.8 307.7 3.9 1.4 2.9
110.0 257.7 247.3 268.0 4.0 1.4 2.8
115.0 224.6 215.3 233.9 4.1 1.5 2.7
120.0 196.4 188.0 204.8 4.3 1.6 2.7
125.0 171.9 164.4 179.5 4.4 1.7 2.6
130.0 150.9 144.1 157.8 4.5 1.8 2.5
135.0 133.3 127.1 139.4 4.6 1.9 2.5
140.0 118.0 112.3 123.6 4.8 2.0 2.4
145.0 104.7 99.55 109.8 4.9 2.1 2.4
150.0 93.08 88.43 97.73 5.0 2.2 2.3
155.0 83.06 78.82 87.30 5.1 2.3 2.3
B57891S0502H008
R/T No. 2003
T (° C) B
55.0
50.0
45.0
Cautions and warnings at the end of this document.
= 3980 K, R25= 5000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
[Ω ] R
min
487890 449130
338250 312760
237690 220700
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
526650
363750
254670
Page 8 of 25Please read Important notes and
7.9 1.1 7.4
7.5 1.0 7.2
7.1 1.0 6.9
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0502H008
R/T No. 2003
T (° C) B
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
= 3980 K, R25= 5000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
169160 157700
121800 113980
88766 83378
65333 61583
48614 45978
36503 34634
27680 26345
21166 20204
16330 15632
12696 12187
9951 9577
7855 7579
6246 6041
5000 4850
4029 3897
3266 3153
2665 2566
2186 2101
1803 1730
1495 1432
1247 1191
1044
[Ω ] R
min
996.0
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
180610
129610
94153
69083
51250
38371
29016
22128
17028
13205
10325
8131
6451
5150
4160
3380
2763
2271
1877
1559
1302
1093
6.8 1.0 6.7
6.4 1.0 6.5
6.1 1.0 6.2
5.7 1.0 6.0
5.4 0.9 5.8
5.1 0.9 5.6
4.8 0.9 5.5
4.5 0.9 5.3
4.3 0.8 5.1
4.0 0.8 5.0
3.8 0.8 4.8
3.5 0.8 4.7
3.3 0.7 4.5
3.0 0.7 4.4
3.3 0.8 4.3
3.5 0.8 4.1
3.7 0.9 4.0
3.9 1.0 3.9
4.1 1.1 3.8
4.3 1.2 3.7
4.5 1.2 3.6
4.6 1.3 3.5
70.0 878.9 836.7 921.1 4.8 1.4 3.4
75.0 743.1 706.2 780.1 5.0 1.5 3.3
80.0 631.0 598.7 663.4 5.1 1.6 3.2
85.0 538.2 509.7 566.6 5.3 1.7 3.1
90.0 460.8 435.7 485.9 5.4 1.8 3.1
95.0 396.1 374.0 418.3 5.6 1.9 3.0
100.0 341.8 322.2 361.4 5.7 2.0 2.9
105.0 296.2 278.8 313.6 5.9 2.1 2.9
110.0 257.7 242.2 273.1 6.0 2.2 2.8
115.0 224.6 210.8 238.4 6.1 2.3 2.7
120.0 196.4 184.1 208.7 6.3 2.4 2.7
125.0 171.9 160.9 182.9 6.4 2.5 2.6
130.0 150.9 141.1 160.8 6.5 2.6 2.5
135.0 133.3 124.4 142.1 6.6 2.7 2.5
140.0 118.0 110.0 126.0 6.8 2.8 2.4
145.0 104.7 97.46 111.9 6.9 2.9 2.4
150.0 93.08 86.57 99.59 7.0 3.0 2.3
155.0 83.06 77.16 88.96 7.1 3.1 2.3
Cautions and warnings at the end of this document.
Page 9 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0502J008
R/T No. 2003
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
= 3980 K, R25= 5000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
487890 439370
338250 306000
237690 215950
169160 154320
121800 111550
88766 81603
65333 60276
48614 45005
36503 33904
27680 25791
21166 19781
16330 15306
12696 11933
9951 9378
7855 7422
6246 5916
5000 4750
4029 3816
3266 3087
2665 2513
2186 2057
1803 1694
1495 1402
1247 1166
1044
[Ω ] R
min
975.1
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
536410
370510
259430
184000
132040
95929
70389
52223
39101
29570
22551
17354
13459
10524
8288
6576
5250
4241
3445
2816
2314
1913
1589
1327
1114
9.9 1.3 7.4
9.5 1.3 7.2
9.1 1.3 6.9
8.8 1.3 6.7
8.4 1.3 6.5
8.1 1.3 6.2
7.7 1.3 6.0
7.4 1.3 5.8
7.1 1.3 5.6
6.8 1.3 5.5
6.5 1.2 5.3
6.3 1.2 5.1
6.0 1.2 5.0
5.8 1.2 4.8
5.5 1.2 4.7
5.3 1.2 4.5
5.0 1.1 4.4
5.3 1.2 4.3
5.5 1.3 4.1
5.7 1.4 4.0
5.9 1.5 3.9
6.1 1.6 3.8
6.3 1.7 3.7
6.5 1.8 3.6
6.6 1.9 3.5
70.0 878.9 819.2 938.7 6.8 2.0 3.4
75.0 743.1 691.4 794.9 7.0 2.1 3.3
80.0 631.0 586.1 676.0 7.1 2.2 3.2
85.0 538.2 499.0 577.4 7.3 2.3 3.1
90.0 460.8 426.5 495.1 7.4 2.4 3.1
95.0 396.1 366.1 426.2 7.6 2.5 3.0
100.0 341.8 315.4 368.2 7.7 2.6 2.9
105.0 296.2 272.9 319.6 7.9 2.8 2.9
110.0 257.7 237.0 278.3 8.0 2.9 2.8
115.0 224.6 206.3 242.9 8.1 3.0 2.7
120.0 196.4 180.2 212.7 8.3 3.1 2.7
125.0 171.9 157.5 186.4 8.4 3.2 2.6
130.0 150.9 138.1 163.8 8.5 3.4 2.5
135.0 133.3 121.7 144.8 8.6 3.5 2.5
Cautions and warnings at the end of this document.
Page 10 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0502J008
R/T No. 2003
T (° C) B
= 3980 K, R25= 5000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
140.0 118.0 107.6 128.3 8.8 3.6 2.4
145.0 104.7 95.36 114.0 8.9 3.8 2.4
150.0 93.08 84.71 101.5 9.0 3.9 2.3
155.0 83.06 75.50 90.62 9.1 4.0 2.3
B57891S0103F008
R/T No. 4901
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
= 3950 K, R25= 10000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
878900 826970
617590 583600
439340 416870
316180 301180
230060 219970
169150 162300
125550 120880
94143 90938
71172 68964
54308 52781
41505 40454
32014 31290
25011 24510
19691 19346
15618 15382
12474 12315
10000 9900
8080 7977
6569 6472
5372 5282
4424 4340
3661 3585
3039 2971
2536 2474
2128 2073
1794 1744
1518 1474
1290 1250
1100 1064
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
930830
651570
461810
331180
240160
175990
130220
97349
73381
55836
42556
32738
25512
20036
15854
12633
10100
8182
6666
5462
4507
3737
3108
2598
2184
1844
1563
1330
1136
5.9 0.8 7.1
5.5 0.8 6.9
5.1 0.8 6.7
4.7 0.7 6.5
4.4 0.7 6.3
4.0 0.7 6.1
3.7 0.6 5.9
3.4 0.6 5.7
3.1 0.6 5.5
2.8 0.5 5.4
2.5 0.5 5.2
2.3 0.4 5.0
2.0 0.4 4.9
1.8 0.4 4.7
1.5 0.3 4.6
1.3 0.3 4.5
1.0 0.2 4.3
1.3 0.3 4.2
1.5 0.4 4.1
1.7 0.4 4.0
1.9 0.5 3.9
2.1 0.6 3.8
2.3 0.6 3.7
2.4 0.7 3.6
2.6 0.8 3.5
2.8 0.8 3.4
3.0 0.9 3.3
3.1 1.0 3.2
3.3 1.0 3.1
90.0 941.8 909.6 974.0 3.4 1.1 3.1
Cautions and warnings at the end of this document.
Page 11 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0103F008
R/T No. 4901
T (° C) B
= 3950 K, R25= 10000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
95.0 809.0 780.1 837.8 3.6 1.2 3.0
100.0 697.2 671.3 723.1 3.7 1.3 2.9
105.0 604.0 580.7 627.2 3.9 1.3 2.9
110.0 524.9 504.0 545.9 4.0 1.4 2.8
115.0 457.3 438.5 476.2 4.1 1.5 2.7
120.0 399.6 382.6 416.6 4.3 1.6 2.7
125.0 350.6 335.2 365.9 4.4 1.7 2.6
130.0 308.4 294.6 322.3 4.5 1.8 2.6
135.0 271.9 259.4 284.5 4.6 1.8 2.5
140.0 240.3 229.0 251.7 4.7 1.9 2.5
145.0 212.8 202.5 223.2 4.9 2.0 2.4
150.0 189.0 179.6 198.3 5.0 2.1 2.4
155.0 168.1 159.6 176.7 5.1 2.2 2.3
B57891S0103H008
R/T No. 4901
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
= 3950 K, R25= 10000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
878900 809390
617590 571250
439340 408080
316180 294860
230060 215370
169150 158920
125550 118370
94143 89055
71172 67540
54308 51695
41505 39624
32014 30649
25011 24010
19691 18952
15618 15070
12474 12065
10000 9700
8080 7816
6569 6340
5372 5174
4424 4252
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
948400
663930
470590
337500
244760
179380
132730
99232
74804
56922
43386
33378
26012
20429
16166
12882
10300
8344
6798
5570
4595
7.9 1.1 7.1
7.5 1.1 6.9
7.1 1.1 6.7
6.7 1.0 6.5
6.4 1.0 6.3
6.0 1.0 6.1
5.7 1.0 5.9
5.4 0.9 5.7
5.1 0.9 5.5
4.8 0.9 5.4
4.5 0.9 5.2
4.3 0.8 5.0
4.0 0.8 4.9
3.8 0.8 4.7
3.5 0.8 4.6
3.3 0.7 4.5
3.0 0.7 4.3
3.3 0.8 4.2
3.5 0.9 4.1
3.7 0.9 4.0
3.9 1.0 3.9
Cautions and warnings at the end of this document.
Page 12 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0103H008
R/T No. 4901
T (° C) B
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
= 3950 K, R25= 10000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
3661 3512
3039 2910
2536 2423
2128 2030
1794 1708
1518 1443
1290 1224
1100 1042
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
3810
3169
2649
2227
1880
1594
1356
1158
4.1 1.1 3.8
4.3 1.2 3.7
4.4 1.2 3.6
4.6 1.3 3.5
4.8 1.4 3.4
5.0 1.5 3.3
5.1 1.6 3.2
5.3 1.7 3.1
90.0 941.8 890.7 992.8 5.4 1.8 3.1
95.0 809.0 763.9 854.0 5.6 1.9 3.0
100.0 697.2 657.4 737.1 5.7 2.0 2.9
105.0 604.0 568.6 639.3 5.9 2.0 2.9
110.0 524.9 493.5 556.4 6.0 2.1 2.8
115.0 457.3 429.3 485.3 6.1 2.2 2.7
120.0 399.6 374.7 424.6 6.3 2.3 2.7
125.0 350.6 328.2 372.9 6.4 2.4 2.6
130.0 308.4 288.4 328.5 6.5 2.5 2.6
135.0 271.9 253.9 289.9 6.6 2.6 2.5
140.0 240.3 224.2 256.5 6.7 2.7 2.5
145.0 212.8 198.3 227.4 6.9 2.9 2.4
150.0 189.0 175.8 202.1 7.0 3.0 2.4
155.0 168.1 156.2 180.0 7.1 3.1 2.3
B57891S0103J008
R/T No. 4901
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
Cautions and warnings at the end of this document.
= 3950 K, R25= 10000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
[Ω ] R
min
878900 791810
617590 558900
439340 399290
316180 288540
230060 210760
169150 155540
125550 115860
94143 87172
71172 66117
54308 50609
41505 38794
32014 30009
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
965980
676280
479380
343830
249360
182760
135240
101110
76228
58008
44216
34019
Page 13 of 25Please read Important notes and
9.9 1.4 7.1
9.5 1.4 6.9
9.1 1.4 6.7
8.7 1.3 6.5
8.4 1.3 6.3
8.0 1.3 6.1
7.7 1.3 5.9
7.4 1.3 5.7
7.1 1.3 5.5
6.8 1.3 5.4
6.5 1.3 5.2
6.3 1.2 5.0
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0103J008
R/T No. 4901
T (° C) B
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0 941.8 871.9
= 3950 K, R25= 10000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
25011 23509
19691 18558
15618 14758
12474 11816
10000 9500
8080 7654
6569 6209
5372 5067
4424 4163
3661 3439
3039 2849
2536 2373
2128 1987
1794 1672
1518 1413
1290 1198
1100 1020
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
26512
20823
16479
13132
10500
8506
6929
5677
4684
3883
3230
2699
2269
1916
1624
1382
1180
1012
6.0 1.2 4.9
5.8 1.2 4.7
5.5 1.2 4.6
5.3 1.2 4.5
5.0 1.2 4.3
5.3 1.3 4.2
5.5 1.3 4.1
5.7 1.4 4.0
5.9 1.5 3.9
6.1 1.6 3.8
6.3 1.7 3.7
6.4 1.8 3.6
6.6 1.9 3.5
6.8 2.0 3.4
7.0 2.1 3.3
7.1 2.2 3.2
7.3 2.3 3.1
7.4 2.4 3.1
95.0 809.0 747.7 870.2 7.6 2.5 3.0
100.0 697.2 643.4 751.0 7.7 2.6 2.9
105.0 604.0 556.5 651.4 7.9 2.8 2.9
110.0 524.9 483.0 566.9 8.0 2.9 2.8
115.0 457.3 420.2 494.5 8.1 3.0 2.7
120.0 399.6 366.7 432.6 8.3 3.1 2.7
125.0 350.6 321.2 380.0 8.4 3.2 2.6
130.0 308.4 282.2 334.7 8.5 3.3 2.6
135.0 271.9 248.5 295.4 8.6 3.4 2.5
140.0 240.3 219.3 261.3 8.7 3.6 2.5
145.0 212.8 194.0 231.7 8.9 3.7 2.4
150.0 189.0 172.0 205.9 9.0 3.8 2.4
155.0 168.1 152.9 183.4 9.1 3.9 2.3
B57891S0203F008
R/T No. 2904
T (° C) B
55.0
50.0
45.0
Cautions and warnings at the end of this document.
= 4300 K, R25= 20000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
[Ω ] R
min
2429200 2275200
1688800 1589200
1184900 1120000
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
2583200
1788400
1249700
Page 14 of 25Please read Important notes and
6.3 0.9 7.3
5.9 0.8 7.1
5.5 0.8 7.0
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0203F008
R/T No. 2904
T (° C) B
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
= 4300 K, R25= 20000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
838770 796240
598950 570900
431350 412750
312810 300440
229310 221030
169020 163470
125850 122120
94153 91646
71126 69440
54237 53105
41719 40963
32409 31906
25367 25038
20000 19800
15884 15679
12654 12461
10148 9971
8205 8045
6673 6528
5449 5320
4474 4359
3692 3590
3061 2971
2551 2471
2135 2065
1799 1736
1521 1466
1290 1242
1099 1055
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
881300
627000
449950
325190
237600
174570
129590
96661
72812
55369
42476
32911
25696
20200
16089
12846
10325
8366
6817
5578
4589
3794
3151
2631
2206
1861
1577
1339
1142
5.1 0.7 6.9
4.7 0.7 6.7
4.3 0.7 6.5
4.0 0.6 6.3
3.6 0.6 6.2
3.3 0.5 6.0
3.0 0.5 5.8
2.7 0.5 5.6
2.4 0.4 5.5
2.1 0.4 5.3
1.8 0.4 5.2
1.6 0.3 5.0
1.3 0.3 4.9
1.0 0.2 4.7
1.3 0.3 4.6
1.5 0.3 4.5
1.7 0.4 4.3
2.0 0.5 4.2
2.2 0.5 4.1
2.4 0.6 4.0
2.6 0.7 3.9
2.8 0.7 3.8
2.9 0.8 3.7
3.1 0.9 3.6
3.3 0.9 3.5
3.5 1.0 3.4
3.6 1.1 3.3
3.8 1.2 3.2
3.9 1.2 3.2
105.0 940.1 901.5 978.6 4.1 1.3 3.1
110.0 807.2 772.9 841.5 4.2 1.4 3.0
115.0 694.9 664.3 725.4 4.4 1.5 3.0
120.0 600.1 572.9 627.3 4.5 1.6 2.9
125.0 520.1 495.8 544.4 4.7 1.7 2.8
130.0 452.2 430.4 473.9 4.8 1.7 2.8
135.0 394.4 374.9 413.9 4.9 1.8 2.7
140.0 345.0 327.5 362.5 5.1 1.9 2.6
145.0 302.8 287.1 318.5 5.2 2.0 2.6
150.0 266.4 252.3 280.6 5.3 2.1 2.5
155.0 235.1 222.3 247.8 5.4 2.2 2.5
Cautions and warnings at the end of this document.
Page 15 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0203H008
R/T No. 2904
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
= 4300 K, R25= 20000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
2429200 2226600
1688800 1555400
1184900 1096300
838770 779460
598950 558920
431350 404120
312810 294180
229310 216440
169020 160090
125850 119600
94153 89762
71126 68018
54237 52021
41719 40128
32409 31258
25367 24531
20000 19400
15884 15362
12654 12208
10148 9768
8205 7881
6673 6395
5449 5211
4474 4270
3692 3516
3061 2910
2551 2420
2135 2022
1799 1700
1521 1436
1290 1216
1099 1033
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
2631700
1822100
1273400
898080
638980
458570
331440
242190
177950
132110
98544
74234
56454
43311
33559
26203
20600
16406
13099
10528
8530
6951
5687
4678
3867
3212
2682
2249
1897
1607
1365
1164
8.3 1.1 7.3
7.9 1.1 7.1
7.5 1.1 7.0
7.1 1.0 6.9
6.7 1.0 6.7
6.3 1.0 6.5
6.0 0.9 6.3
5.6 0.9 6.2
5.3 0.9 6.0
5.0 0.9 5.8
4.7 0.8 5.6
4.4 0.8 5.5
4.1 0.8 5.3
3.8 0.7 5.2
3.6 0.7 5.0
3.3 0.7 4.9
3.0 0.6 4.7
3.3 0.7 4.6
3.5 0.8 4.5
3.7 0.9 4.3
4.0 0.9 4.2
4.2 1.0 4.1
4.4 1.1 4.0
4.6 1.2 3.9
4.8 1.3 3.8
4.9 1.3 3.7
5.1 1.4 3.6
5.3 1.5 3.5
5.5 1.6 3.4
5.6 1.7 3.3
5.8 1.8 3.2
5.9 1.9 3.2
105.0 940.1 882.7 997.4 6.1 2.0 3.1
110.0 807.2 756.7 857.6 6.2 2.1 3.0
115.0 694.9 650.4 739.3 6.4 2.2 3.0
120.0 600.1 560.9 639.3 6.5 2.3 2.9
125.0 520.1 485.4 554.8 6.7 2.4 2.8
130.0 452.2 421.4 482.9 6.8 2.5 2.8
135.0 394.4 367.0 421.8 6.9 2.6 2.7
Cautions and warnings at the end of this document.
Page 16 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0203H008
R/T No. 2904
T (° C) B
= 4300 K, R25= 20000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
140.0 345.0 320.6 369.4 7.1 2.7 2.6
145.0 302.8 281.0 324.5 7.2 2.8 2.6
150.0 266.4 246.9 285.9 7.3 2.9 2.5
155.0 235.1 217.6 252.5 7.4 3.0 2.5
B57891S0203J008
R/T No. 2904
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
= 4300 K, R25= 20000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
2429200 2178000
1688800 1521600
1184900 1072600
838770 762690
598950 546940
431350 395490
312810 287920
229310 211850
169020 156710
125850 117080
94153 87879
71126 66595
54237 50936
41719 39294
32409 30610
25367 24024
20000 19000
15884 15044
12654 11955
10148 9565
8205 7717
6673 6261
5449 5102
4474 4180
3692 3442
3061 2848
2551 2369
2135 1980
1799 1664
1521 1405
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
2680300
1855900
1297100
914850
650960
467200
337700
246770
181330
134620
100430
75657
57539
44145
34208
26710
21000
16724
13352
10731
8694
7084
5796
4768
3941
3273
2733
2291
1933
1637
10.3 1.4 7.3
9.9 1.4 7.1
9.5 1.4 7.0
9.1 1.3 6.9
8.7 1.3 6.7
8.3 1.3 6.5
8.0 1.3 6.3
7.6 1.2 6.2
7.3 1.2 6.0
7.0 1.2 5.8
6.7 1.2 5.6
6.4 1.2 5.5
6.1 1.1 5.3
5.8 1.1 5.2
5.6 1.1 5.0
5.3 1.1 4.9
5.0 1.1 4.7
5.3 1.2 4.6
5.5 1.2 4.5
5.7 1.3 4.3
6.0 1.4 4.2
6.2 1.5 4.1
6.4 1.6 4.0
6.6 1.7 3.9
6.8 1.8 3.8
6.9 1.9 3.7
7.1 2.0 3.6
7.3 2.1 3.5
7.5 2.2 3.4
7.6 2.3 3.3
Cautions and warnings at the end of this document.
Page 17 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0203J008
R/T No. 2904
T (° C) B
95.0
100.0
105.0 940.1 863.9
= 4300 K, R25= 20000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
1290 1190
1099 1011
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
1391
1186
1016
7.8 2.4 3.2
7.9 2.5 3.2
8.1 2.6 3.1
110.0 807.2 740.6 873.8 8.2 2.7 3.0
115.0 694.9 636.5 753.2 8.4 2.8 3.0
120.0 600.1 548.9 651.4 8.5 3.0 2.9
125.0 520.1 475.0 565.2 8.7 3.1 2.8
130.0 452.2 412.4 492.0 8.8 3.2 2.8
135.0 394.4 359.2 429.7 8.9 3.3 2.7
140.0 345.0 313.7 376.3 9.1 3.4 2.6
145.0 302.8 275.0 330.6 9.2 3.5 2.6
150.0 266.4 241.6 291.2 9.3 3.7 2.5
155.0 235.1 212.9 257.2 9.4 3.8 2.5
B57891S0104F008
R/T No. 4003
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
= 4450 K, R25= 100000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
10381000 9704000
7370700 6923600
5272300 4975500
3798800 3600800
2756500 2623900
2014200 1925100
1480100 1420100
1097600 1056900
817440 789950
614070 595430
463310 450710
352440 343920
269950 264220
208310 204480
161890 159350
126660 125010
100000 99000
78351 77336
62372 61415
49937 49056
40218 39419
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
11058000
7817900
5569100
3996700
2889100
2103400
1540200
1138200
844930
632710
475910
360950
275680
212140
164430
128320
101000
79367
63329
50818
41018
6.5 1.0 6.8
6.1 0.9 6.7
5.6 0.8 6.6
5.2 0.8 6.5
4.8 0.8 6.4
4.4 0.7 6.2
4.1 0.7 6.1
3.7 0.6 6.0
3.4 0.6 5.8
3.0 0.5 5.7
2.7 0.5 5.5
2.4 0.4 5.4
2.1 0.4 5.3
1.8 0.4 5.1
1.6 0.3 5.0
1.3 0.3 4.9
1.0 0.2 4.8
1.3 0.3 4.6
1.5 0.3 4.5
1.8 0.4 4.4
2.0 0.5 4.3
Cautions and warnings at the end of this document.
Page 18 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0104F008
R/T No. 4003
T (° C) B
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
= 4450 K, R25= 100000 Ω , TR= 25 ° C, ∆ RR/RR= ± 1%
25/100
R
[Ω ] R
nom
32557 31839
26402 25765
21527 20964
17693 17195
14616 14176
12097 11710
10053 9714
8376 8079
7004 6743
5894 5665
4978 4776
4215 4037
3580 3424
3050 2913
2607 2485
2233 2126
1919 1824
1652 1568
1425 1351
1237 1171
1076 1017
[Ω ] R
min
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
33275
27040
22091
18191
15055
12483
10393
8673
7265
6123
5179
4392
3736
3188
2728
2340
2013
1735
1499
1303
1134
2.2 0.5 4.2
2.4 0.6 4.1
2.6 0.7 4.0
2.8 0.7 3.9
3.0 0.8 3.8
3.2 0.9 3.8
3.4 0.9 3.7
3.6 1.0 3.6
3.7 1.1 3.5
3.9 1.1 3.4
4.0 1.2 3.4
4.2 1.3 3.3
4.4 1.3 3.2
4.5 1.4 3.2
4.7 1.5 3.1
4.8 1.6 3.0
4.9 1.7 3.0
5.1 1.7 2.9
5.2 1.8 2.9
5.3 1.9 2.8
5.5 2.0 2.8
155.0 939.3 886.9 991.8 5.6 2.1 2.7
B57891S0104H008
R/T No. 4003
T (° C) B
55.0
50.0
45.0
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
Cautions and warnings at the end of this document.
= 4450 K, R25= 100000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
[Ω ] R
min
10381000 9496300
7370700 6776200
5272300 4870100
3798800 3524800
2756500 2568800
2014200 1884800
1480100 1390500
1097600 1035000
817440 773600
614070 583150
463310 441440
352440 336870
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
11266000
7965300
5674500
4072700
2944300
2143700
1569800
1160200
861280
644990
485180
368000
Page 19 of 25Please read Important notes and
8.5 1.2 6.8
8.1 1.2 6.7
7.6 1.2 6.6
7.2 1.1 6.5
6.8 1.1 6.4
6.4 1.0 6.2
6.1 1.0 6.1
5.7 1.0 6.0
5.4 0.9 5.8
5.0 0.9 5.7
4.7 0.9 5.5
4.4 0.8 5.4
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0104H008
R/T No. 4003
T (° C) B
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0 939.3 868.1
= 4450 K, R25= 100000 Ω , TR= 25 ° C, ∆ RR/RR= ± 3%
25/100
R
[Ω ] R
nom
269950 258820
208310 200310
161890 156120
126660 122480
100000 97000
78351 75769
62372 60168
49937 48057
40218 38614
32557 31188
26402 25237
21527 20533
17693 16841
14616 13884
12097 11468
10053 9513
8376 7911
7004 6603
5894 5547
4978 4677
4215 3953
3580 3353
3050 2852
2607 2433
2233 2081
1919 1785
1652 1535
1425 1323
1237 1146
1076
[Ω ] R
min
995.5
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
281080
216310
167670
130850
103000
80934
64577
51817
41822
33926
27568
22521
18545
15347
12725
10594
8841
7405
6241
5279
4476
3808
3249
2780
2385
2052
1768
1528
1327
1156
1011
4.1 0.8 5.3
3.8 0.7 5.1
3.6 0.7 5.0
3.3 0.7 4.9
3.0 0.6 4.8
3.3 0.7 4.6
3.5 0.8 4.5
3.8 0.9 4.4
4.0 0.9 4.3
4.2 1.0 4.2
4.4 1.1 4.1
4.6 1.1 4.0
4.8 1.2 3.9
5.0 1.3 3.8
5.2 1.4 3.8
5.4 1.5 3.7
5.6 1.5 3.6
5.7 1.6 3.5
5.9 1.7 3.4
6.0 1.8 3.4
6.2 1.9 3.3
6.4 2.0 3.2
6.5 2.1 3.2
6.7 2.1 3.1
6.8 2.2 3.0
6.9 2.3 3.0
7.1 2.4 2.9
7.2 2.5 2.9
7.3 2.6 2.8
7.5 2.7 2.8
7.6 2.8 2.7
B57891S0104J008
R/T No. 4003
T (° C) B
55.0
50.0
45.0
Cautions and warnings at the end of this document.
= 4450 K, R25= 100000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
[Ω ] R
min
10381000 9288700
7370700 6628800
5272300 4764600
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
11474000
8112700
5780000
Page 20 of 25Please read Important notes and
10.5 1.5 6.8
10.1 1.5 6.7
9.6 1.5 6.6
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
B57891S0104J008
R/T No. 4003
T (° C) B
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0 939.3 849.3
= 4450 K, R25= 100000 Ω , TR= 25 ° C, ∆ RR/RR= ± 5%
25/100
R
[Ω ] R
nom
3798800 3448800
2756500 2513700
2014200 1844500
1480100 1360900
1097600 1013000
817440 757260
614070 570870
463310 432180
352440 329820
269950 253420
208310 196140
161890 152880
126660 119940
100000 95000
78351 74201
62372 58920
49937 47058
40218 37810
32557 30537
26402 24709
21527 20103
17693 16487
14616 13591
12097 11226
10053 9312
8376 7744
7004 6463
5894 5429
4978 4577
4215 3869
3580 3281
3050 2791
2607 2381
2233 2037
1919 1747
1652 1502
1425 1294
1237 1121
1076
[Ω ] R
min
974.0
[Ω ] ∆ RR/RR[± %] ∆ T[±° C] α (%/K)
max
4148700
2999400
2184000
1599400
1182100
877630
657270
494440
375050
286480
220480
170910
133380
105000
82501
65824
52816
42627
34577
28096
22952
18899
15640
12967
10795
9009
7545
6359
5378
4561
3880
3310
2832
2430
2090
1801
1556
1352
1178
1029
9.2 1.4 6.5
8.8 1.4 6.4
8.4 1.4 6.2
8.1 1.3 6.1
7.7 1.3 6.0
7.4 1.3 5.8
7.0 1.2 5.7
6.7 1.2 5.5
6.4 1.2 5.4
6.1 1.2 5.3
5.8 1.1 5.1
5.6 1.1 5.0
5.3 1.1 4.9
5.0 1.1 4.8
5.3 1.1 4.6
5.5 1.2 4.5
5.8 1.3 4.4
6.0 1.4 4.3
6.2 1.5 4.2
6.4 1.6 4.1
6.6 1.6 4.0
6.8 1.7 3.9
7.0 1.8 3.8
7.2 1.9 3.8
7.4 2.0 3.7
7.6 2.1 3.6
7.7 2.2 3.5
7.9 2.3 3.4
8.0 2.4 3.4
8.2 2.5 3.3
8.4 2.6 3.2
8.5 2.7 3.2
8.7 2.8 3.1
8.8 2.9 3.0
8.9 3.0 3.0
9.1 3.1 2.9
9.2 3.2 2.9
9.3 3.3 2.8
9.5 3.4 2.8
9.6 3.5 2.7
Cautions and warnings at the end of this document.
Page 21 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
Cautions and warnings at the end of this document.
Page 22 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
Cautions and warnings
General
See "Important notes" at the end of this document.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature 25 ° C ... +45 ° C, relative
humidity ≤ 75% annual mean, maximum 95%, dew precipitation is inadmissible.
Do not store SMDs where they are exposed to heat or direct sunlight. Otherwise, the packing
material may be deformed or SMDs may stick together, causing problems during mounting.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environments like corrosive gases (SOx, Cl etc).
After opening the factory seals, such as polyvinyl-sealed packages, use the SMDs as soon as
possible.
Solder thermistors after shipment from EPCOS within the time specified:
SMDs: 12 months
Leaded components: 24 months
Handling
NTC thermistors must not be dropped. Chip-offs must not be caused during handling of NTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering
Use resin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Mounting
When NTC thermistors are encapsulated with sealing material or overmolded with plastic
material, the precautions given in chapter “Mounting instructions”, “Sealing, potting and
overmolding” must be observed.
Electrode must not be scratched before/during/after the mounting process.
Contacts and housings used for assembly with thermistor have to be clean before mounting.
During operation, the thermistor’s surface temperature can be very high (ICL). Ensure that
adjacent components are placed at a sufficient distance from the thermistor to allow for proper
cooling ot the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of the thermistor. Be sure that surrounding parts and materials can
withstand this temperature.
Make sure that thermistors (ICLs) are adequately ventilated to avoid overheating.
Avoid contamination of thermistor surface during processing.
Cautions and warnings at the end of this document.
Page 23 of 25 Please read Important notes and
Temperature measurement B57891
Leaded NTCs, lead spacing 2.5 mm S891
Operation
Use thermistors only within the specified operating temperature range.
Use thermistors only within the specified voltage and current ranges (ICLs).
Environmental conditions must not harm the thermistors. Use thermistors only in normal
atmospheric conditions.
Contact of NTC thermistors with any liquids and solvents should be prevented. It must be
ensured that no water enters the NTC thermistor (e.g. through plug terminals). For
measurement purposes (checking the specified resistance vs. temperature), the component
must not be immersed in water but in suitable liquids (e.g. Galden).
Avoid dewing and condensation.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by malfunction (e.g. use VDR for limitation of overvoltage condition).
Cautions and warnings at the end of this document.
Page 24 of 25 Please read Important notes and
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application . These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application .
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic compon-
ents or failure before the end of their usual service life cannot be completely ruled out
in the current state of the art, even if they are operated as specified. In customer applica-
tions requiring a very high level of operational safety and especially in customer applications
in which the malfunction or failure of a passive electronic component could endanger human
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured
by means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed .
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time . The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products . Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, EPCOS-JONES, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will
be found on the Internet at www.epcos.com/trademarks.
Page 25 of 25