查询B57867S0103+140供应商
B57867Temperature Measurement
S867Miniature Sensors
Applications
■ Heating and air conditioning systems
■ Industrial electronics
■ Automotive electronics
Features
■ Fast response
■ High measuring accuracy
■ Different tolerances available
■ Epoxy resin encapsulation
■ Silver-plated nickel leads
Options
Non-standard lead lengths
Delivery mode
Bulk
Climatic category (IEC 60068-1)
Max. power at 25
Resistance tolerance ∆RN/R
Rated temperature T
°C P
25
N
B value tolerance ∆B/B
Dissipation factor (in air)
Thermal cooling time constant (in air) τ
Heat capacity C
δ
th
c
th
ø2,41 max.
6,5 max.
50±2
ø0,25
TNT0394-H
Dimensions in mm
Approx. weight 60 mg
55/155/56
60
N
± 1 %, ± 3 %, ± 5 %
25
mW
°C
± 1 %
approx. 1,5
approx. 12
approx. 18
mW/K
s
mJ/K
R
25
No. of R/T
B
25/100
Ordering code
characteristic
Ω
K
2 k 1008 3560 B57867S0202+140
3 k 8016 3988 B57867S0302+140
5 k 8016 3988 B57867S0502+140
10 k 8016 3988 B57867S0103+140
30 k 8018 3964 B57867S0303+140
50 k 2901 3760 B57867S0503+140
100 k 2014 4540 B57867S0104+140
∆R
∆R
∆R
N/RN
N/RN
N/RN
= ± 1 %
= ± 3 %
= ± 5 %
+: F for
Hfor
Jfor
94 05/02
Reliability data
Test Standard Test conditions
Storage in
dry heat
IEC
60068-2-2
Storage at upper
category temperature
°C
T: 155
t: 1000 h
Storage in damp
heat, steady state
IEC
60068-2-3
Temperature of air: 40
Relative humidity of air: 93 %
Duration: 56 days
Rapid temperature
cycling
IEC
60068-2-14
Lower test temperature: – 55
Upper test temperature: 155
Number of cycles: 100
Long-term stability
(empirical value)
Temperature: 70
t: 10 000 h
°C
°C
∆R
25/R25
(typical)
< 1 %/
1)
< 2 %
< 1 % No visible
< 1 % No visible
°C
°C
< 2 % No visible
B57867Temperature Measurement
S867Miniature Sensors
Remarks
No visible
damage
damage
damage
damage
1) For B57867S0302-+140