EPCOS B57236 User Manual

查询B57236S0259L002供应商
N/RN
= ± 15 %
B57236Inrush Current Limiters
S236Insulation Voltage 1000 VDC for 1 s, R
Applications
Switch-mode power supplies
Features
Close resistance tolerance,
improved insulation voltage
Useable in series connections up to 265 V
Kinked leads of tinned copper wire
Wide resistance range
UL approval (E69802)
rms
Delivery mode
Bulk (standard), cardboard tape, reeled or in Ammo pack
Climatic category (IEC 60068-1) Max. power at 25 Resistance tolerance RN/R Rated temperature T
°C P
max
N
B value tolerance B/B Dissipation factor (in air) Thermal cooling time constant (in air) τ Heat capacity C Test voltage (t = 1 s) V
δ
th
c
th
T
ø11,5 max.56 max.
_
TNT0413-S
16 max.
136
ø0,8
Dimensions in mm Approx. weight 1,7 g
55/170/56 2,4
N
± 15 %
25
W
°C
± 3 %
approx. 14 approx. 50 approx. 700 1000
mW/K s mJ/K VDC
1)
R
25
I
max
(0 65 °C) A
No. of R/T char­acteristic
B
K
25/100
C
230 V
µF
1)
C
T
Parameters for
T
110 V
R(I)
µF
kn
1)
Ordering code
2,5 5,5 1201 2700 200 800 0,621 – 1,27 B57236S0259L002
3,0 5,0 1202 2800 300 1200 0,80 – 1,31 B57236S0309L002
5,0 4,5 1202 2800 300 1200 0,761 – 1,30 B57236S0509L002
8,0 3,7 1203 2900 300 1200 1,11 – 1,34 B57236S0809L002
1) For details on the capacitance CT as well as on the parameters k and n refer to Application Notes, pages 40 –42.
134 05/02
N/RN
Reliability data
Test Standard Test conditions
Storage in dry heat
IEC 60068-2-2
Storage at upper category temperature T: 170
°C
t: 1000 h
Storage in damp heat, steady state
IEC 60068-2-3
Temperature of air: 40 Relative humidity of air: 93 % Duration: 21 days
Rapid temperature cycling
IEC 60068-2-14
Lower test temperature: – 55 Upper test temperature: 170 Number of cycles: 10
Endurance I = I
max
t: 1000 h
Cyclic endurance
, 1000 cycles
I = I
max
On-time = 1 min Cooling time = 6 min
Transient load
Capacitance = C Number of cycles: 1000
= ± 15 %
°C
T
R
25/R25
(typical)
< 10 % No visible
< 5 % No visible
< 10 % No visible
°C
°C
< 10 % No visible
< 10 % No visible
< 5 % No visible
B57236Inrush Current Limiters
S236Insulation Voltage 1000 VDC for 1 s, R
Remarks
damage
damage
damage
damage
damage
damage
135 05/02
Loading...