MOQ = Minimum Order Quantity, consisting of 4 packing units.
For new design, please refer to the B3292xE/F data sheet.
Further intermediate capacitance values on request.
MOQ = Minimum Order Quantity, consisting of 4 packing units.
For new design, please refer to the B3292xE/F data sheet.
Further intermediate capacitance values on request.
For the following types the safety approvals are pending:
B32926C3156M000, B32926D3156K000, B32926D3156M000
B32928C3206K000, B32928C3206M000, B32928C3256K000, B32928C3256M000,
B32928C3306M000
Important notes at the end of this document.
Page 5 of 17Please read Cautions and warnings and
Technical data
B32921C/D ... B32928C/D
X2 / 305 V AC
Max. operating temperature T
Dissipation factor tan δ (in 10-3)
at 20 °C (upper limit values)
op,max
+110 °C
CR≤0.1 µF 0.1µF<CR≤2.2 µF CR>2.2 µF
at
1 kHz1.01.02.0
100 kHz5.0
Insulation resistance R
ins
or time constant τ = CR R
ins
CR≤0.33 µFCR>0.33 µF
100 000 MΩ 30 000 s
at 20 °C, rel. humidity ≤ 65%
(minimum as-delivered values)
DC test voltage2121 V, 2 s
Passive flammability category
B
to IEC 40 (CO) 752
Maximum continuous DC voltage V
Maximum continuous AC voltage V
630 V
DC
310 V (50/60 Hz)
AC
Rated AC voltage (IEC 60384-14)305 V (50/60 Hz)
Operating AC voltage Vopat high
temperature
TA≤ 110 °CVop= V
AC
TA≤ 110 °CVop= 1.25 VAC(1000 h)
Damp heat test56 days / 40 °C / 93% relative humidity
Limit values after damp heat testCapacitance change ∆C/C≤ 5%
Dissipation factor change ∆ tan δ ≤ 0.5 10-3(at 1 kHz)
Insulation resistance R
ins
or time constant τ = CR R
≤ 1.0 10-3(at 10 kHz)
≥ 50% of minimum
ins
as-delivered values
(continuously)