EOS EmoTouch 3 Users guide

EN
EmoTouch 3
Control Unit for Sauna Cabins
Made in Germany
Operating Instructions
Druck-Nr.: 2902 5151 Stand: 48/20
EN
Documentation
Manufacturer
EOS Saunatechnik GmbH Schneiderstriesch 1 35759 Driedorf, Germany Tel. +49 2775 82-514 Fax +49 2775 82-431 Email servicecenter@eos-sauna.com Web www.eos-sauna.com
Original installation instructions EN
Copyright for these installation instructions remains with EOS Saunatechnik GmbH. Copyright as per DIN ISO 16016: The copying and distribution of this document, as well as the use and com­munication of its contents without express authorisation, are not permit­ted. Compensation will be claimed in the event of infringements. All rights reserved with regard to patent claims or submission of design or utility patent.
Characters, symbols and illustrations
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step Table title
Title of figure
Revision history
Date Versi on Description
1 Aug. 2020 01.00 First version 15 Jan. 2021 01.10 Chapters Safety, Standards and regulations, and Potential-free contact updated
EN-2 Operating Instructions - EmoTouch 3

Contents

Documentation..................................................................................................EN-2
1 General safety instructions ..........................................................................EN-5
1.1 Safety levels................................................................................................EN-5
1.2 Operation and settings..........................................................................EN-6
1.3 Operator instruction ...............................................................................EN-7
1.4 Standards and regulations ...................................................................EN-9
2 Identification ....................................................................................................EN-10
2.1 EmoTouch 3 control panel .................................................................EN-10
2.2 Intended use............................................................................................EN-11
3 Description of the units ...............................................................................EN-12
3.1 Scope of delivery....................................................................................EN-12
3.2 Technical data .........................................................................................EN-14
4 Commissioning ...............................................................................................EN-15
4.1 Configuration upon commissioning or after a reset ................EN-16
4.2 Defining the light source manually ................................................EN-23
5Operation............................................................................................................EN-26
5.1 User interface .........................................................................................EN-26
5.2 Working with the graphic user interface.......................................EN-27
5.3 Switching the system on/off..............................................................EN-28
5.4 Basic settings ..........................................................................................EN-31
5.4.1 Setting the temperature .....................................................EN-32
5.4.2 Selecting the operating mode..........................................EN-33
5.4.3 Setting the humidity for Bi-O mode................................EN-34
5.4.4 Dimming or switching the light on/off..........................EN-36
5.4.5 Retrieving temperature/humidity values .....................EN-37
5.4.6 Switching ECO mode on/off ..............................................EN-38
5.4.7 Switching on HOT mode.....................................................EN-41
5.4.8 Switching potential-free contact on/off........................EN-43
5.5 Advanced settings ................................................................................EN-44
5.5.1 Advanced settings – single installation.........................EN-45
5.5.2 Advanced settings – multi-cabin installation..............EN-46
5.5.3 Language selection...............................................................EN-50
5.5.4 Screen saver ............................................................................EN-52
5.5.5 Standby mode.........................................................................EN-53
5.5.6 Operational lock/child lock ................................................EN-54
5.5.7 Display brightness.................................................................EN-56
5.5.8 Holiday cottage mode ........................................................EN-57
5.5.9 Operating data .......................................................................EN-59
EmoTouch 3 - Operating Instructions EN-3
EN
5.5.10 Heating period – auto stop ..............................................EN-61
5.5.11 Automatic start time............................................................ EN-63
5.5.12 One-time heating period ..................................................EN-65
5.5.13 Recurring heating periods ................................................ EN-69
5.5.14 Coloured light coupling...................................................... EN-76
5.6 Error messages.......................................................................................EN-79
6Service settings............................................................................................... EN-80
6.1 Service level ............................................................................................ EN-80
6.1.1 Opening service settings.................................................... EN-82
6.1.2 Service/maintenance........................................................... EN-83
6.1.3 Switching hysteresis ............................................................EN-84
6.1.4 Reset function ........................................................................ EN-85
6.1.5 Temperature control............................................................ EN-86
6.1.6 Setting the potential-free contact .................................. EN-87
6.1.7 Fan levels ................................................................................. EN-89
6.1.8 Fan post-cycle period ......................................................... EN-90
6.1.9 Refill period ............................................................................. EN-92
6.1.10 Post-heating time ................................................................. EN-93
6.1.11 Post-heating temperature ................................................. EN-94
6.1.12 HOT function .........................................................................EN-95
6.1.13 Setting the ECO runtime .................................................... EN-97
6.1.14 HOME function....................................................................... EN-98
6.2 Data transfer and updates ...............................................................EN-100
6.2.1 Configuration backup ......................................................EN-101
6.2.2 Updating firmware .............................................................EN-104
6.2.3 Exporting the operating data.........................................EN-107
7 General terms and conditions of service .........................................EN-108
8Disposal............................................................................................................EN-111
EN-4 Operating Instructions - EmoTouch 3

General safety instructions

WAR NING
CAUTION
NOTICE
General safety instructions

1.1 Safety levels

Safety instructions and important operating instructions are clas­sified according to ANSI Z535.6. Please familiarise yourself with the following terms and symbols:
Warning
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Caution
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Notice
Indicates a hazardous situation which, if not avoided, will result in damage to the unit.
EmoTouch 3 - Operating Instructions EN-5
EN
General safety instructions

1.2 Operation and settings

These operating instructions are intended for the personnel re­sponsible for the operation of a sauna cabin. Observe the follow­ing general safety instructions during set-up and operation.
Risk to life and limb
and risk of fire
Fire hazard from
overheating
Risk to life and limb from electric shock and fire in the event of im­proper or faulty electrical connection. This risk also applies follow­ing completion of the installation work. The electrical installation of the relay box and other electrical
systems or equipment with a fixed mains connection must only be performed by a trained electrician from an authorised elec­trical company.
Observe the stipulations in VDE 0100 part 701.The system must be disconnected and removed entirely from
the mains supply before commencing installation and repair work.
The housing cover must only be removed by a specialist.
Insufficient ventilation can lead to device overheating and fire. Flammable parts must not exceed a temperature of 140°C when the unit is operated as intended or in the event of a malfunction. Do not install control panels, relay boxes and modules in en-
closed cabinets or wood panelling.
Observe the sauna heater manufacturer's safety and installa-
tion instructions.
Observe the cabin manufacturer's safety and installation in-
structions.
Touchable glass surfaces on the outside of the cabins could
reach a maximum of 76°C. Attach safety devices if needed.
Damage to the unit Corrosive or heavy saline atmospheres damage the contacts in the
control panel, in the relay box and in the sensors. The control panel and sensors should not be installed in a cor-
rosive or heavy saline atmosphere.
EN-6 Operating Instructions - EmoTouch 3
General safety instructions
Damage due to
incorrect mounting
location
The control unit is not suitable for outdoor use. It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity and moisture or the possible formation of condensation or cor­rosive substances in the ambient air, as well as other weather conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.

1.3 Operator instruction

The operator of the infrared or sauna cabin must be instructed in the general safety instructions during commissioning. The opera­tor must be given a copy of the operating instructions. The operator must make the end user aware of safety instructions that are relevant to the end user.
Risk of electric shock A risk t o life and lim b from elect ric shock and fire arises i n the event
of improper repair work. This risk also applies after work is com­pleted.
The unit covers must only be removed by a specialist.Repairs and installations must only be performed by a trained
specialist.
The system must be disconnected and removed entirely from
the mains supply before commencing repair work.
Use only original spare parts from the manufacturer.
Fire hazard Objects placed on the sauna heaters can easily be ignited and
cause fires.
Do not place objects on the sauna heater.If you switch on the sauna heater using pre-set timers or a re-
mote control, attach a protective cover to the heater or install a suitable safety device.
Inspect the cabin prior to commissioning. When using control units with a remote control option (see
EN 60335-1), protection from switching on a covered sauna heater is required.
EmoTouch 3 - Operating Instructions EN-7
EN
General safety instructions
Risk of burns and
chemical burns
Health risks Spending time in an infrared or sauna cabin can lead to serious
Equipment damage
due to overuse
Touching hot parts may lead to skin burns and chemical burns of the skin. The operator must be familiar with the unit's hot parts and be
able to identify them.
The operator must be familiar with the settings for the heating
period and understand how it is controlled.
health risks or even death for persons with health impairments. Persons with health impairments who spend time in a sauna
must consult a doctor before entering an infrared or sauna cab­in.
The uninterrupted operation time of the sauna cabin(s) can lead to property damage. If the sauna cabin is used commercially, the heating time must
be set so that it switches o ff automatically after a specific period of time.
If the heating does not switch off automatically after a defined
heating period, cabin use must be supervised at all times.
Inspect the cabin before each use.
Operation by
children or persons
with reduced mental
capacity
Children and persons with reduced mental capacity can be a risk. Children must be supervised to ensure they do not play with
the unit.
Children under 8 years of age should not operate the sauna
cabin.
The settings for the heating time must only be used by children
under 8 years of age if they are supervised by an adult.
The sauna cabin must only be used by persons with reduced
mental capacity, or limited physical or sensory abilities under supervision or if they have already been instructed in its use and understand the risks.
Children and persons who have not received proper instruction
must not clean or service the system.
EN-8 Operating Instructions - EmoTouch 3
General safety instructions

1.4 Standards and regulations

For an overview of the standards that were observed during design and construction of the sauna heaters, please refer to the individual product's technical data sheet that can be downloaded from www.eos-sauna.com. Local regulations also apply to the installation and operation of heating, sauna, and steam room systems.
EmoTouch 3 - Operating Instructions EN-9
EN
Saunasteuergerät/Control unit
IPX4
Type EmoTouch 3 Bedienteil / Control Panel Art. Nr. 94 6505 00 400 V 3N AC 50 Hz
Max. Schaltleistung 9 kW
Made in Germany
EOS SAUNATECHNIK GmbH, 35759 Driedorf
S-No. 0010915.19
A
B C
D E
F G
H I

Identification

Identification
The EmoTouch 3 control unit consists of a relay box, a control panel, a tem­perature sensor and the connecting cables, and is used to operate a sauna cabin.

2.1 EmoTouch 3 control panel

The nameplate is attached to the back of the control panel.
EN-10 Operating Instructions - EmoTouch 3
A Name F Country of origin B Model G Manufacturer C Item number H Manufacturing date D Operating voltage I Serial number E Maximum switching output (kW)
Nameplate (example)
Requirements for operation and storage
The control panel must be installed outside of sauna cabins only. The mounting location must meet the following climate condition require­ments:
Ambient temperature during operation -10°C to 35°CStorage temperature: -20°C to 60°C
Identification

2.2 Intended use

In conjunction with a suitable sauna heater, the EmoTouch 3 control unit is intended to be used only to heat sauna cabins. It is suitable for cabins used in private and commercial settings. The relay box and control panel are intended only for mounting on the wall. The control unit is not suitable for outdoor use. It must be operated only inside buildings and may not be exposed to envi­ronmental conditions such as extreme humidity and moisture or the possi­ble formation of condensation or corrosive substances in the ambient air, as well as other weather conditions. Similarly, excessive cold and extreme exposure to sunlight must be prevented. Protect the unit accordingly if there is an increased risk of mechanical damage.
EmoTouch 3 relay box
The relay box is used to operate sauna heaters in Finnish mode and in humidity mode.
EmoTouch 3 control panel
The EmoTouch 3 control panel is suitable for the operation of sauna cabins in private and commercial settings. It must be mounted on a wall.
Foreseeable misuse
The following are considered instances of foreseeable misuse:
The control and sensor cable plugs are plugged in incorrectly.The unit is operated without knowledge of or compliance with the
safety instructions.
Operating, service and maintenance requirements are not observed.The unit is operated after technical or other modifications are made to
the relay box.
The unit is operated by children or persons with reduced mental capac-
ity or by persons who have not been thoroughly instructed in its use.
The manufacturer is not liable for unauthorised modifications made to the equipment and damages resulting from these modifications. The person modifying the equipment alone shall bear the associated risk.
General safety instructions,  EN-5
EmoTouch 3 - Operating Instructions EN-11
EN
A
B
G
I
K
C D FE
J
H

Description of the units

Description of the units

3.1 Scope of delivery

The following components are included in the scope of delivery:
A Relay box with 2-piece front cover B 8 bushings C 3 wood screws 4 x 25 mm D 5 m connecting cable with RJ14/RJ10 modular plug for
control panel
E Removal tools for control panel
EmoTouch 3 scope of delivery
Check the scope of delivery for completeness prior to installation.
EN-12 Operating Instructions - EmoTouch 3
F EmoTouch 3 control panel with housing for mounting
in the wall
G Installation and operating instructions H Ferrite ring for data lines I Line for safety temperature limiter J Spare fuse for safety temperature limiter K Temperature sensor including 5 m connecting cable
with RJ10 plug, housing, circuit board, 2 screws 4x40 mm
Description of the units
Accessories (optional)
Accessories Item no.
20 m connecting cable for temperature sensor 94.6281 50 m connecting cable for temperature sensor 94.6282 10 m connecting cable for control panel (RJ10/RJ14) 94.6802 25 m connecting cable for control panel (RJ10/RJ14) 94.6285 50 m connecting cable for control panel (RJ10/RJ14) 94.6968 100 m connecting cable for control panel (RJ10/RJ14) 94.6969 10 m connecting cable for sauna bus (RJ12/RJ12) 94.5861 25 m connecting cable for sauna bus (RJ12/RJ12) 94.4647 50 m connecting cable for sauna bus (RJ12/RJ12) 94.4648 Mains adapter 230 V for control panel with cable length >
25 m Bench sensor 94.5725 Humidity sensor 94.5726 SBM-HOT (button) 94.6800 SBM-ECO (button) 94.6980 IR module as installation add-on 94.6966 IR plug-in module with adapter cable 94.2046 IR plug-in module without adapter cable 94.4960
2.5 m connecting cable for IR plug-in module 94.4396 Set SBM ECO push button 94.6980 SBM-WCI-01 web app module 94.5987 SBM remote start 94.5782 SBM-FL75/150 coloured light module 94.5996, 94.6007 SBM-S BT sound module 94.5920, 94.5921 Infrared receiver for coloured light module and sound mod-
ule SBM-GLT-MOD HOME Modbus module 94.7077 SBM-GLT-KNX HOME KNX module 94.7078 Modular distributor RJ12 for connecting cable for control
panel and sauna bus
94.6671
94.6810
2001.5298
EmoTouch 3 - Operating Instructions EN-13
EN
Description of the units

3.2 Technical data

Power supply 400 V 3 N AC 50 Hz Switching output Max. 9 kW resistive load, upgrade with LSG units possible Fuse 3 x 16 A Ambient temperature -10°C to +35°C S1 output Max. 50 W/50 VA (no capacitive loads) Supply for terminal area/sauna
heater connection Terminal area WM, 3, 4, light, fan 0.34–2.5 mm² rigid or flexible with wire-end ferrule. Observe minimum cross-sec-
Potential-free contact Load rating of contact for resistive loads:
Storage temperature -20°C to +60°C Relay box housing Plastic Dimensions (H x W x D) 270 x 300 x 100 mm
Weight Relay box: approx. 1.5 kg Relay box outputs/inputs 3 x RJ10 jack for sensor connection
Control panel outputs/inputs 4 x RJ10 jack for relay box and multi-cabin connection
Display Colour capacitive 7" touchscreen display in 16:9 format
Heating time limitation Up to 6hrs/12hrs/18hrs/infinite Temperature control 30°C–115°C (dry sauna mode)
Humidity regulation Time-proportionally or optionally according to % rel. air humidity with connected
Sensor system Digital sensor with safety temperature limiter 139°C Control characteristics Digital two-point control Connection for fan* Min. 5 W, max.150 W (only fan without starting capacitor)
Connection for lighting* Min. 5W (20mA), resistive load, max. 100W
0.5–2.5 mm² rigid or flexible with wire-end ferrule, two conductors with identical cross-section per terminal can be connected.
tions for fuse protection for the supply line.
- Maximum power supply: 10 A
- Maximum voltage: 30 VDC/250 VAC
Control panel: 142 x 210 x 42 mm, mounting depth approx. 37 mm
2 x RJ14 jack for control panel and add-on modules
1 x connection for memory card (input/host, jack type A) Connection for power adapter 24 V DC
Error display: Text on the display
30°C–70°C (humidity mode)
humidity sensor
Use only fans that are suitable for phase control, otherwise the fan or the control unit can be damaged.
Dimmable energy-saving bulbs, max. 35 W Light source with conventional transformers, max. 60 VA. Use only dimmable light sources.
* Fan and light connections are protected by a joint 2AF fuse.
EN-14 Operating Instructions - EmoTouch 3

Commissioning

A
Commissioning
A Unit switch on relay box
In order to commission the sauna cabin, the cabin must be switched on at the control panel. If the display is blank, the relay box might be switched off. A unit switch is located on the left side of the relay box.
Position I: Relay box is switched on (factory setting). The relay box is ready for operation in standby mode.
Position 0: Relay box is completely switched off. Parts of the circuit board are still under current.
Position II: Cabin lighting is switched on, relay box is switched off. Position for maintenance and cleaning.
EmoTouch 3 - Operating Instructions EN-15
EN
Commissioning

4.1 Configuration upon commissioning or after a reset

The control panel automatically switches to standby mode once connec­tion to the relay box has been established and it is connected to the mains supply. The settings must be redefined upon commissioning and after a complete system reset. The program guides you through the required steps.
Defining the user interface language
1 Tap the desired language.
Setting
Language
BG CN CZ DE DK EN FIN FR
HR HU IT NL PL RO RU SE
SK SLO SP TR
2 Tap the language again to confirm the selection.
Once confirmed, the display moves to the next setting.
01. June 2019
08:44:40
EN-16 Operating Instructions - EmoTouch 3
Commissioning
Setting the time
1 Set the hours with and , and then confirm.
Setting
Time
08 : 00
01. June 2019
08:41:40
The active place value appears in blue.Pressing and holding the button changes the value in increment
mode.
2 Set the minutes and confirm.
Setting the date
1 Set the day, month, and year by pressing and , and then con-
firm.
Setting
Date
01.06.2019
01. June 2019
08:42:40
The active place value appears in blue.
EmoTouch 3 - Operating Instructions EN-17
EN
Commissioning
Specifying the place of operation
1 Press or to confirm the prompt that asks if the system is being
operated in a country of the EU/CENELEC.
Setting
Safety
Is the sauna installed in the EU / CENELEC?
01. June 2019
08:43:40
European Union/CENELEC must be selected if the system is installed
in countries under the jurisdiction of the CENELEC.
Once EU/CENELEC is selected, specific provisions of the EU/CENELEC
apply, e.g. the time limit for operation.
Selecting the operating mode
1 Tap the desired operating mode.
Setting
Operation mode
Default: up to 8 Cabins
1 Steam cabin with up to 4 Steam generators and optional up to 4 additional cabins
2 Steam cabins each with up to 4 Steam genera­tors
2 Steam cabins each with up to 2 Steam genera­tors and optional up to 4 additional cabins
01. June 2019
08:44:40
EN-18 Operating Instructions - EmoTouch 3
Commissioning
Choose this setting if one steam generator or one sauna
heater per cabin is controlled. For more information about installing multiple cabins, see the installation instructions.
Choose this setting if one cabin is served by 1–4 steam
generators. Additionally, 4 more cabins can be controlled with steam generators or sauna cabins.
Choose this setting if 2 cabins, each with up to 4 steam
generators, are operated.
Choose this setting if 2 steam room cabins, each with up to
2 steam generators, are operated. Additionally, 4 sauna cabins or IR cabins can be operated.
2 Confirm the selection.
Defining the type of use
1 Press or to specify whether the system will be used for private
or commercial purposes.
Setting
Usage
private use
01. June 2019
08:45:40
a) Private use
b) Commercial use
Specific safety regulations apply to this setting. See 1.3 Operator
instruction, EN-7
2 Confirm the selection by pressing .
EmoTouch 3 - Operating Instructions EN-19
EN
Commissioning
Security settings
1 Press or to specify whether the system will be operated with a
safety device.
Setting
Safety
Safety system as per norm EN 60335 for remotecontrol / timecontrol available?
01. June 2019
Cabin
08:46:40
A safety device must be present to set up one-time and recurring
heating periods, the remote start function, and the Web App WCI module.
If you confirm the prompt by pressing , a message stating that
the system does not comply with safety standards is displayed. Confirm the message.
Selecting the heater type
1 Press or to specify whether the sauna heater will be operated
with or without a vaporiser.
Setting
Heater type
with vaporiser
Cabin 1
01. June 2019
09:16:42
EN-20 Operating Instructions - EmoTouch 3
Commissioning
a) Heater type without vaporiser for Finnish sauna.
b) Heater type with vaporiser.
Select how the heater is displayed after selecting the skin for the
cabin. Selecting skins, EN-21
2 Confirm the selection by pressing .
Selecting skins
1 Open skin selection by pressing .
Settings
Skin selection
IR
01. June 2019
Cabin 1
10:32:14
The display shows only the installed and detected modules.
Information about setting up the module can be found in each of the individual installation and operating instructions.
EmoTouch 3 - Operating Instructions EN-21
EN
Settings
Skin selection
sauna heater 1
Cabin 1
01. June 2019
10:32:14
Cubo
Commissioning
2 Press the lower arrows or to scroll through the skins and con-
firm your selection.
Settings
Skin selection
01. June 2019
10:32:14
After selecting the skin and the heater image, selection of the
connected module is displayed again.
If the installation is a multi-cabin installation, the cabin image and the
module for each cabin are set.
3 Confirm the selection by pressing .
4 Press the lower arrows or to scroll through the heater images
and confirm the image for the sauna heater you want.
EN-22 Operating Instructions - EmoTouch 3
After selecting the heater image, selection of the connected module
is displayed again.
5 Confirm the selection by pressing .
This completes the initial setup. If the installation is a multi-cabin installa­tion, you must set the cabin image and the heater image for each cabin.
Commissioning
NOTICE
R,L
R,C
Add-on modules or accessories are detected once the unit is switched on (again) and their corresponding icons appear on the cabin image and in the sub-menus.
Additional settings:
5.4 Basic settings,  EN-31 chapter Service settings,  EN-80

4.2 Defining the light source manually

The control unit is set to inductive loads by the factory so that resistive loads can also be controlled by the control panel. If required, the light out­put can also be manually set to capacitive loads. If light bulbs are used, the load for lighting must remain as an inductive load. The current setting is shown on the display.
Display symbol Setting Code
Inductive/resistive load (lighting for phase con­trol), if light bulbs are used. Factory setting
Capacitive load (lighting for phase control) Electrical ballasts for phase-cut dimmer
8001
8002
Material damage
Lighting and the control unit could become damaged if non-dim­mable light sources are installed. In this case, the warranty be­comes void. Work must only be performed by a trained technician from an
authorised company specialised in the trade.
Do not mount lights near rising steam.The lighting must conform to protection class IP65 and be re-
sistant to ambient temperatures.
Connect only dimmable light sources.
For this setting, the lighting must be disconnected.
EmoTouch 3 - Operating Instructions EN-23
EN
0
123 456 789
C
Setting
code
01. June 2019
08:44:40
Commissioning
Setting the load for lighting to resistive load
1 WARNING! Ensure that the relay box is disconnected from the power
supply. Open the relay box's housing. Refer to the installation instructions.
2 Disconnect the light source from the relay box.
3 Reconnect the power supply and switch on the relay box and control
panel.
4 Press and hold for 3 seconds.
5 Enter the code and confirm.
Code 8001: Inductive load/resistive load, e.g. if light bulbs are used.Code 8002: Capacitive load.
6 Disconnect the relay box from the mains supply and reconnect the light
source.
7 Close the housing again.
8 Reconnect the relay box to the power supply and switch it on.
EN-24 Operating Instructions - EmoTouch 3
Commissioning
L
Setting
Light
01. June 2019
12:45:40
100%
9 Press and hold the light icon on the display for 3 seconds.
01. June 2019
12:45:40
The icon for the current lighting load setting is displayed.
10 Check the setting on the display.
EmoTouch 3 - Operating Instructions EN-25
EN
E G H J
B
L
M
O
N
A
D
C
KIF

Operation

Operation
The figures show examples of the display and settings.

5.1 User interface

0:45:40
A Cabin image B Temperature/humidity detector C Potential-free contact D Status bar E On/off (cabin) F Current status, e.g. amount of time
remaining
EmoTouch 3 graphic user interface layout – example
G Settings H Warning (for a different cabin) I Actions and information, e.g.
J Current cabin (for multi-cabin
The touch screen function icons are displayed in various colours:
!
humidity mode
installation)
3
K Date, time, and possibly timer
setting
L EOS logo (touch recognition) M Cabin lighting N Sound (optional) O Coloured light (optional)
01. June 2019
14:22:38
Grey: Function button is inactiveWhite: Function available, function button is selectedGreen: Function button Confirm is selectedRed: Function button Delete is selectedBlue: Settings, e.g. for timer
EN-26 Operating Instructions - EmoTouch 3
Operation
Texts are displayed in the following colours:
White: Status texts, e.g. date, name of sub-menuBlue: active input digits, e.g. for date, time, timer displayRed: Warning, time display for auto-stop
Display
The display switches to standby mode if there is no activity for a defined period of time. You can cancel standby mode by tapping the display. Tap any area on the cabin image to close an open sub-menu.
Sub-menus close automatically if the display is not touched for
10 seconds. After that, the start screen is displayed.
If you have a multi-cabin installation, you can switch to the start screen
by tapping the cabin number in the status bar.
All cabin settings are made at the control panel. At least one cabin must be set up for commissioning.

5.2 Working with the graphic user interface

The graphic user interface displays icons depending on the selection. Their use is described below:
Tap briefly on the cabin image: The function is switched on or off. Tap briefly on the sub-menu: The icon is selected. Tap again: The selection is confirmed. Press and hold: A sub-menu opens. Tap anywhere on the cabin image: The sub-menu for settings closes.
Heat on/off Settings
Next Back to previous selection or
start
Confirm selection Clear selection
Increase the value by 1. Decrease the value by 1.
The home screen (standby) appears after the display has not been touched for 10 seconds.
Settings that have not been saved are lost. Date and time are saved if the built-in battery is charged and in working
order. All other settings are saved permanently.
EmoTouch 3 - Operating Instructions EN-27
EN
Operation
Add-on modules or accessories are detected once the unit is switched on again and their corresponding images appear on the cabin image or in the sub-menus. The display illustrations in these operating instructions always show exam­ples with optional features. Unit operation and unit settings are available on different levels:
User level Private operation
Commercial opera­tion
Service level Settings for service technician (with PIN code)
Basic settings (per cabin) Advanced settings (with PIN code)

5.3 Switching the system on/off

In a multi-cabin installation, you can start and end each cabin individually or all cabins at the same time.
Switching on a single installation, EN-29Switching the system off, EN-31
Instead of starting the system manually, you can set an automatic start time or define a single start date.
Setting the automatic start time, EN-63Setting a one-time heating period, EN-65
EN-28 Operating Instructions - EmoTouch 3
Operation
01. June 2019
12:45:40
0:45:40
Switching on a single installation
1 Press and hold for 3 seconds.
If you have not selected a cabin in the multi-cabin installation, all
cabins are started via the cabin overview. To prevent an overload of the mains supply, each cabin is started with a slight delay.
01. June 2019
12:45:40
Example: Single installation
The system is started using the parameters set for each cabin.
The red (glowing) stones indicate that the heater is on.
EmoTouch 3 - Operating Instructions EN-29
EN
01. June 2019
12:45:40
0:45:40
Operation
Switching on cabins in a multi-cabin installation
1 Select the cabin in the cabin overview.
Settings
Select Cabin
1
567
234
8
01. June 2019
07:44:40
If you have not selected a cabin in the cabin overview, all cabins are
started. To prevent an overload of the mains supply, each cabin is started with a slight delay.
2 Press and hold for 3 seconds.
The system is started using the parameters set for each cabin.
The red (glowing) stones indicate that the heater is on in the selected
cabin.
EN-30 Operating Instructions - EmoTouch 3
Loading...