01
Gold Standard After Sales Service
In the unlikely event of any on-site installation problems or queries regarding the EnviroVent heatSava, just call our hotline number. We will take your details and appoint a regional installation manager to call you back to discuss the problem. In the majority of cases, the problem can be resolved over the phone. However, in cases where the problem cannot be resolved over the phone, we will arrange a visit from our Gold Standard Engineer. They will meet with your contractor/direct labour on-site to discuss and resolve the problem, will provide training and also give advice on the installation of the unit.
INSTALLER HOTLINE: 07540 050 147
01 Introduction
Thank you for choosing EnviroVent
The fastest growing ventilation company in the UK
Ensure that this product is treated with care, installed and maintained correctly i.e. for the life of the building. Remember, if you have any problems please call our dedicated
Technical Team.
AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
02
02 Technical Specications
Unit Dimensions
Cowl End
Heat Cell
Fan Adaptor
Assembly
(Supply Fan)
Centre Assembly
(Electronics)
Front Cover
Rear Assembly
(Extract Fan)
SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
02 Technical Specications
Heat Cells Options
Ø100
Ø150
03
Wall Depth mm
(A)
Cell Order Size mm
(B)
100 - 330 330
331 - 430 430
431 - 500 500
501 - 600 600
AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
04
03 Wiring Diagrams
Mains - This unit must be earthed
Connect 2 core & earth cable into existing wiring
SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
05
03 Wiring Diagrams
SELV - This unit must be earthed
Connect 2 core cable from SELV box into unit
Connect 2 core & earth cable to existing wiring
2 core & earth2 core
SELV
2 core
2 core & earth
SELV Box must be secured using the 4
xing points
Cables must be restrained inside SELV box
SELV Box
Power Supply
GND
V+
GND V+
AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
06
04 Safety
Never modify the fan or electronics.
Do not store inammable products in the
vicinity of this product.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
For a bathroom application the power supply should be installed outside the bathroom as it is 230V.
Be sure to have read and understood these instructions before beginning the installation process.
IPX4 Rated
This unit has been tested to IPX4 and is suitable for installation within Zone 1 of bathrooms. However, we recommend that you must not position the unit above any water devices such as taps, shower heads or jets and ensure water is not aimed directly at the unit. Do not use jets or shower heads etc to clean this unit.
All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent
standards for your country. The nal
installation should be examined and
tested by a qualied electrician.
Make sure the mains supply complies with the rating label for voltage, frequency and phase.
IMPORTANT: This unit draws air in from atmosphere and you must ensure that any emissions from any other systems such as gas or oil boilers, do not contaminate the air entering the heatSava product. Therefore, before installation, consider where the external cowl will be located in relation to any
boiler ues etc. Externally, you must
ensure that the unit is positioned a minimum distance away of; 1 metre horizontally, 1 metre below or 3 metres
above any boiler ue etc.
In kitchens, if the unit has to be tted
above a cooker, it must be installed a minimum distance of 650mm above electric cookers and 750mm above gas
cookers, and not have a pullcord tted.
SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
07
04 Safety
Electrical Assembly
When wiring the unit in, a suitable disconnect device such as a fused spur should be used, do not use a plug. The means of disconnecting the unit from the mains power supply must be incorporated
in the xed wiring in accordance with the
wiring rules.
There must be a necessity to allow disconnection of the appliance from the supply after installation, unless the appliance incorporates a switch complying with the wiring regulations The disconnection may be achieved by incorporating a switch in the
xed wiring in accordance with the wiring
regulations.
The electrical install comprises of a power supply unit (Fig.1) or a low voltage box
- SELV (Fig.2). See pages 4-5 for wiring diagrams.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualied persons in
order to avoid a hazard.
SELV Box
MAINS
Fig.1
Fig.2
Fan
Board
Power
Supply
Connect 2 core & earth cable into existing wiring
Connect 2 core cable from SELV box into unit
Connect 2 core & earth cable to existing wiring
2 core & earth2 core
SELV
Cables must be restrained inside SELV box.
AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER
DO NOT THROW AWAY
05 Box Contents
1 heatSava Unit
2 Heat Cell
3 Instructions Guide
4 SELV (optional)
5 Halo
6 Wall Seal
7 Fixing Template
8 Fixing Kit
08
SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
09
05 Box Contents
Description Quantity Item
heatSava Unit 1x
Heat Cell 1x
Instructions Guide 1x
SELV (optional) 1x
Halo
(Wall Kit Contents)
1x
Wall Seal 1x
Fixing Template 1x
Fixing Kit 1x
8G X 2.0” -
(Fixing Kit Contents)
6x
Red Wall Plugs -
(Fixing Kit Contents)
6x
Terminal Block
(Spare)
1x