The PHI CELL
The PHI CELL Advanced Oxidation Systems is designed to help eliminate sick building syndrome risks by reducing odors, air pollutants, and cold and virus causing germs through a patent pending Photohydroionization® (PHI) process. The PHI Cells are contained within the APS unit. When the APS system is in operation, the PHI Cell uses an Advanced Oxidation Process to reduce airborne contaminants.
Why use Photohydroionization?
Germicidal UV light rays have been used for decades by the medical industry as a method for destroying micro-organisms (germs, viruses, bacteria). Germicidal UV light is effective in reducing airborne micro­organisms that pass through the light rays. However, germicidal UV light has little to no effect on gases, vapors or odors.
Ozone, on the other hand, is very effective on gases, vapors and odors. However, too much ozone can be a health hazard, and traditional methods of producing ozone (i.e., corona discharge) have maintenance problems and create nitric acid and nitric oxides. The combination of ozone (O3) and UV light, in the presence of the PHI catalyst, creates the Advanced Oxidation reaction. This patent pending reaction chamber creates ozone gas and destroys it within the same chamber. This process, in combination with the
which germicidal light can kill micro­organisms, it also produces super oxide ions and hydro-peroxides. These products of Advanced Oxidation further attack the micro-organisms as well as significantly reducing odors and VOC’s. The PHI reaction cell has the added benefit of producing safe, low levels of ozone as a by-product of the PHI cell. This low level ozone further cleanses the air as it travels through the ductwork. By engineering the proper light wavelength and a dual function, no maintenance PHI Cell, the manufacturer has effectively designed a system that will not exceed the recommended Federal Safety Limits for ozone (0.04 ppm) in an occupied room.
With the PHI CELL, most gases and odors are abated while micro-organisms can be reduced by as much as 90%, and the room will have safe, low ozone levels no greater than forest air, or air after a thunderstorm, which gives the room fresh, clean and odor-free air.
catalytic target surface of the cell, produces not only an atmosphere in
PIP Manual Page 3
Page 3
INSTALLATION INSTRUCTIONS
DANGER: For outlet installation only,
type of power source. Improper installation could result in electrical shock or short.
never connect to an extension cord or other
1. Find a convenient wall outlet. Plug the unit into the outlet. Note: It is not recommended to place the PIP unit into an outlet equipped with a GFCI (Ground Fault Circuit Interrupter) device. If the GFCI is tripped, it will not be possible to reset the outlet GFCI device (unless the PIP is physically removed from the outlet). In installations requiring a GFCI circuit, it is recommended that the breaker box be equipped with a GFCI breaker to protect the outlet circuit.
2. Turn off power at the breaker panel for the outlet (restore when installation is complete).
3. Remove the PIP cover and install anti-theft screws (Note: as the wall material will vary from installation to installation, the wall mounting security screws are not provided). Please use the appropriate type of fasteners for the substrate encountered in each installation location (2-1/2” long fasteners are recommended).
4. Fasten the security screws into the provided holes going through the back of the unit. In wall installations with wood or metal studs you will need to locate which side the stud is positioned on, and then use the corresponding holes in the unit (two holes located to the left of center, or two holes located to the right of center).
5. Note: A light duty mounting option is included with the unit. This is for low traffic areas such as storage rooms and similar areas that do not require an anti-theft type of mounting.
Locate the appropriate outlet and disconnect power to it at the breaker box.
Remove the center screw from the outlet plate cover.
Plug unit into the outlet (be sure outlet cover is still in place), and secure unit and
outlet plate to outlet using provided 6-32 X2” machine screw.
Mounting Holes (2)
Center Mounting Holes (1)
Remove Cover Screws (2)
Mounting holes
PIP Manual Page 5
Page 4
OPERATION
After completing the installation, you can now operate the unit. Operation is controlled via a switch, located on the side of the unit.
Low-Off-High Switch
PIP Manual Page 7
Page 5
LAMP REPLACEMENT PROCEDURE
Caution: Before attempting to service the Plug-In unit, be sure the power is off to the
unit/outlet.
DANGER:
UV LIGHT WILL BURN YOUR EYES.
NEVER LOOK DIRECTLY AT UV LIGHT.
1. Remove cover (ensure power is off to outlet before removing)
Figure 1
2. Pull out PHI Cell from chassis. Replace with new PHI Cell.
Figure 2
3. Replace cover.
Restore power.
PIP Manual Page 9
Page 6
REPLACEMENT PART NUMBERS
Component Cell
PHI Cell PHIC-5A
PIP Manual Page 11
Page 7
LIMITED WARRANTY
This warranty supersedes and replaces any warranty statements made orally by the Sales Person, Distributor, or Dealer, or contained within the written instructions or other brochures or informational documents related to this product.
Manufacturer warrants the new PHI CELL equipment to be free from defects in material and workmanship under normal use and service when operated and maintained in strict accordance with manufacturer’s instructions for a period of thirty six (36) months from the date of receipt of equipment.
Manufacturer’s obligation under this warranty is limited to repairing or replacing any part found to its satisfaction to be so defective. This warranty does not cover parts damaged by decomposition from chemical action or wear caused by abrasive materials, nor does it cover damage resulting from misuse, abuse, or any use other than the intended use, accident, neglect, or from improper operation, maintenance, installation, modification or adjustments.
Manufacturer assumes no liability for any harm that may occur as a result of the use of this equipment and shall not be liable for consequential or any other damages, whether or not caused by manufacturer’s negligence or resulting from any express or implied warranty or breach thereof. Consequential damages for the purpose of this warranty shall include, but not be limited to, loss of use, income, profit, or damages to property, or injury or death to persons or animals occasioned by or arising out of operation, use, installation, repair or replacement of the equipment or otherwise.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF.
To obtain warranty service or warranty return authorization number, contact the factory.
Manufacturer: RGF Environmental Group, Inc.
Include a copy of your Bill of Sale, Invoice or Receipt of Purchase, with an explanation of the problem or defect.
Hg- LAMP CONTAINS MERCURY
PIP Manual Page 13
Manage in accord with disposal laws See: www.lamprecycle.org
Page 8
WARRANTY REQUEST FORM
RETURN AUTHORIZATION NO. __________________________
CUSTOMER: NAME _______________________________________________________
ADDRESS _______________________________________________________
CONTACT _______________________________________________________
DISTRIBUTOR: NAME ________________________________________________________ ADDRESS _______________________________________________________ CONTACT _______________________________________________________
UNIT: MODEL _______________________________________________________ SERIAL ________________________________________________________ DATE OF PURCHASE _____________________________________________
ITEM(S) SUBMITTED FOR WARRANTY:
1) __________________________________________________________________________
2) __________________________________________________________________________
COMMENTS: ____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
(FOR MANUFACTURER USE ONLY)
DATE ITEM(S) RECEIVED: _____________________________________________________________
RECEIVED BY: _______________________________________________________________________
REPLACEMENT UNIT OR PART SENT
COMMENTS: ________________________________________________________________________
NOTE: THIS COMPLETED FORM MUST ACCOMPANY ALL RETURNED ITEMS.
PIP Manual Page 14
Loading...