Installation Manual
Model EC-3040 Vertical
Read carefully all of this manual prior to installing the unit.
Model EC-4824 Horizontal
![](/html/9f/9f11/9f11aa74222b782e960a45f68ca23457bfa158aa7f33f28bfd2c882cf727dbb4/bg2.png)
System Design and Layout
or rooms that desire the lowest comfort
Each QuietCool fan can only be installed in a room that has an attic above or adjacent to it, or has a
1500 fan installed, and/or a QC-
ool or a QuietCool fan in each room or to have the
ool to the fan go through each room that is to be cooled.
SIZING
most eectively in cooling each type home.
The type and size of home is the main factor that determines how much air should be moved through it
which give the necessary air exchanges per hour to provide sucient cooling.
Rules of thumb have been developed to arrive at satisfactory results for most conditions.
1. For newly or recently constructed homes that have tight envelopes and are insulated to recent high
2. For homes in cool coastal climates, the CFM’s can be reduced by 20%
3. For homes in hot desert climates, the CFM’s should be increased by 25%
4. For poorly insulated homes and homes that are not well sealed, the CFM’s should be increased by
5. For homes with high or vaulted ceilings, the CFM’s should be increased by 10%
6. The model number of the QuietCool fan designates its CFM performance. For example, a QuietCool
1. One EnviroCool unit is generally adequate for up to 1,750 square feet of oor space. Two EnviroCools
2. This general rule is based upon the premise that the rooms in the home that are in the pathway of
he rst step is to determine what size system, or how many EnviroCools and QuietCool fans would work
he climate zone is an important factor, and the type of construction of the home is also a consideration.
QUIETCOOL FAN SIZING RULES
standards, 300 CFM (cubic feet per minute) of fan performance should be added for each 100 square
feet of living space. For example, a 2000 sq. ft. home should have approximately 6000 CFM fan
performance.
20%.
QC-1500 has 1500 CFM performance, and a QC-4500 has 4500 CFM performance.
ENVIROCOOL SIZING RULES
are needed for homes up to 3,500 sq. ft., and add one additional EnviroCool for each additional 1,750
sq. ft. thereafter.
the moving air from the EnviroCool to each QuietCool fan will be cooled eectively. Those rooms not
in the pathway may not achieve satisfactory comfort levels. To overcome this problem, additional
EnviroCools can be added to these rooms if required.
(Example: Increase from 4 to 5 fans)
LAYOUT
Each home needs to be studied and planned so that the placement of QuietCool fans and EnviroCools
will achieve the optimum performance. The following rules will be helpful.
1. Each EnviroCool must be installed in an exterior wall. It should be on the lower oor of a multi-
home.
2. The best layout for the EnviroCool is to place it in the room
level temperatures and are as far removed as possible from the location of the fans.
to the EnviroCool will be coolest, and the rooms farthest from it will be the warmest.
3.
roof directly above it.
4. When QuietCool fans are mounted in an attic, it must be ascertained that the attic has (or is
of having) vents to the outside in the amount of one square foot for each 750 CFM of fan
5. In single story houses, the fan (or fans) should be located as far as possible from the EnviroCool
location. It is recommended that each bedroom and oce have a QC4500 installed in a master bath. In multi story houses, the fans should be placed in upper story
6. The fans should generally be placed near the center of each room, to allow cooling by drawing air
from the Enviro
7. The ideal arrangement is to have either an EnviroC
pathway of air moving from the EnviroC
ool, or from an open window when outside air is cool.
LAYOUT RULES
2
![](/html/9f/9f11/9f11aa74222b782e960a45f68ca23457bfa158aa7f33f28bfd2c882cf727dbb4/bg3.png)
System Sizing and Venting
Home Size (Sq. Ft.)EnviroCool QC 1500 Fan QC 4500 Fan *Total Fans Venting Required
1,000 - 1,500 1 4 0 4 8 sq. ft.
1,500 - 1,750 1 3 1 6 12 sq. ft.
1,800 - 2,500 2 4 1 7 14 sq. ft.
2,500 - 3,000 2 5 1 8 16 sq. ft.
3,000 - 3,500 2 6 1 9 18 sq. ft.
3,500 - 4,000 2 4 2 10 20 sq. ft.
4,000 - 4,500 3 5 2 11 22 sq. ft.
4,500 - 5,000 3 4 3 13 26 sq. ft.
5,000 - 5,500 3 5 3 14 28 sq. ft.
5,500 - 6,000 3 6 3 15 30 sq. ft.
* Total fans equal to one QC 1500 - ie. one QC4500 = QC 1500 fans.
Homes with vaulted ceilin
s in main area ad 1.25 percent to entire home sizei.e. 2,000 (sq. ft.) x 1.25 = 2,500 sq. ft.
Gable vent Dormer vent Eave vent Ridge vent Soffet vent
Average size 12" x 19.5"
Venting Sq. Ft. 1.20 0.70 0.35
14" x 8"
3.5" x 22.5"
various various
various various
THESE SAMPLE FLOOR PLANS SHOW EXAMPLES OF PROPER PLACEMENTS.
Single Story Example
(2,047 sq. ft)
Patio
Nook
EC
Bedroom
QC
Family Room
Bath
QC
G
Master
Bedroom
QC
Kitchen
Dining Room
EC
Living Room
Bedroom
QC
Bath
Bedroom
Legend
QC
EnviroCool
EC
QC
QC 1500 Fan
QC
QC 4500 Fan
G
Garage
Air movemet
Air direction
(when used with open windows)
3
QC fan air intake
![](/html/9f/9f11/9f11aa74222b782e960a45f68ca23457bfa158aa7f33f28bfd2c882cf727dbb4/bg4.png)
EC
Two Story Example
(2,489 sq. ft)
First Floor Plan
Patio
EC
Dining Room
Living Room
Kitchen
Family Room
UP
Patio
Garage
Second Floor Plan
QC
G
Bath
QC
Master
Bedroom
Bath
QC
Bedroom
4
Bedroom
Bedroom
QC
QC
Legend
EnviroCool
EC
QC
QC 1500 Fan
QC
QC 4500 Fan
G
Air movemet
Air direction
(when used with open windows)
QC fan air intake