Installation Data Sheet..................................................................................16
2
Introduction
* This manual is designed for the home owner in conjunction with the technical manual. *
RATING LABEL LOCATION:
The rating label is located on the back of the ash pan cover.
PELLET QUALITY:
Pellet quality is important, please read the following:
Your enviro pellet stove has been designed to burn wood pellets only. Do not use any other
type of fuel, as this will void any warranties stated in this manual.
The performance of your pellet stove is greatly affected by the type and quality of wood
pellets being burned. As the heat output of various quality wood pellets differs, so will the
performance and heat output of the pellet stove.
CAUTION: It is important to select and use only pellets that are dry and free of dirt or any impurities
such as high salt content. Dirty fuel will adversely affect the operation and performance of the unit
and will void the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet
manufacturers. We recommend the use of pellets that meet or exceed these standards. Ask your dealer
for a recommended pellet type.
P.F.I. PELLET STANDARDS:
Fines (fine particles)......1% maximum through a ” screen
Bulk Density..................40 pound per cubic foot minimum
Size..............................” to 5/16” diameter – 1” long maximum
Ash Content..................1% maximum (Premium grade)
..................3% maximum (Standard grade)
Moisture Content...........8% maximum
Heat Content.................approximately 8200 Btu per pound minimum
ASH: The ash content of the fuel and operation of your stove will directly determine the frequency of
cleaning. The use of high ash fuels may result in the stove needing to be cleaned daily. A low ash fuel
may allow longer intervals between cleaning.
CLINKERING: [clinkers are silica (sand) or other impurities in the fuel that will form a hard mass during
the burning process]. This hard mass will block the air flow through the Burn Pot Liner and affect the
performance of the stove. Any fuel, even approved types, may tend to clinker. Check the Burn-Pot Liner
daily to ensure that the holes are not blocked with clinkers. If they become blocked, remove the liner
(when the unit is cold) and clean/scrape the clinkers out. Clean the holes with a small pointed object if
required. Refer to the section Routine Cleaning and Maintenance.
PELLET FEED RATES: Due to different fuel densities and sizes, pellet feed rates may vary. This may
require an adjustment to the slider damper setting or to the auger feed trim setting on low.
Since Sherwood Industries Ltd. has no control over the quality of pellets that you use, we assume no
liability for your choice in wood pellets.
Store pellets at least 36” (1 m) away from the pellet stove.
3
Introduction
IMPORTANT SAFETY DATA:
Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet
Stove. Failure to follow these instructions may result in property damage, bodily injury
or even death. Contact your local building or fire official to obtain a permit and any information on
installation restrictions and inspection requirements for your area.
To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering to the
installation instructions. An ENVIRO dealer will be happy to assist you in obtaining information with
regards to your local building codes and installation restrictions.
Be sure to maintain the structural integrity of the home when passing a vent through walls, ceilings, or
roofs.
The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive
chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash
pan and viewing door must be locked securely for proper and safe operation of the pellet stove.
Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper
combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by
adjusting the slider damper located on the left side of the stove.
When installing the stove in a mobile home, it must be electrically grounded to the steel chassis of the
home and bolted to the floor. Make sure that the structural integrity of the home is maintained and all
construction meets local building codes.
Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an
extremely rich burn (black tipped, lazy orange flames).
If you have any questions with regard to your stove or the above-mentioned information, please feel free
to contact your local dealer for further clarification and comments.
SAFETY WARNINGS AND RECOMMENDATIONS:
Caution: Do not connect to any air distribution duct or system.
Do not burn garbage or flammable fluids such as gasoline, naptha or engine oil.
Unit hot while in operation. Keep children, clothing and furniture away. Contact
may cause skin burns.
FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash
content. Dirty fuel will adversely affect the operation and performance of the unit and may void the
warranty. Check with your dealer for fuel recommendations.
THE USE OF CORDWOOD IS PROHIBITED BY LAW.
SOOT: Operation of the stove with insufficient combustion air will result in the formation of soot which
will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the
house. This is a dangerous situation and is inefficient. Frequently check your stove and adjust the slider/
damper as needed to ensure proper combustion. See: “SLIDER/DAMPER SETTING”.
CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This
will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect
and clean the exhaust vent semi-annually or every two tons of pellets.
ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container
4
Introduction
of ashes should be on a non-combustible floor on the ground, well away from all combustible materials
pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they
should be retained in the closed container until all cinders have been thoroughly cooled.
ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be
grounded. The grounded electrical cord should be connected to a standard 110-120 volts, nominal
average 2.0 Amps (4.1 Amps peak), 60 hertz electrical outlet and also must be accessible. Ensure the
polarity to the outlet, the unit will be plugged into, is correct as incorrect polarity can affect the unit’s
operation. If this power cord should become damaged, a replacement power cord must be purchased
from the manufacturer or a qualified ENVIRO dealer. Be careful that the electrical cord is not trapped
under the appliance and that it is clear of any hot surfaces or sharp edges. This unit’s maximum power
requirement is 184 watts (600 watts peak).
GLASS: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove
with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO
dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is
hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner,
or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the
glass.
FLAMMABLE LIQUIDS:Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter
fluid, or similar liquids to start or “freshen up” a fire in the heater. Keep all such liquids well away from
the heater while it is in use.
SMOKE DETECTOR: Smoke detectors should be installed and maintained in the structure when
installing and operating a pellet burning appliance.
OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet
stove. Also ensure all gaskets on the door are checked and replaced when necessary.
KEEP ASH PAN FREE OF RAW FUEL.
DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A fire in the ash pan may occur.
INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through
walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any
displacement.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
FRESH AIR: Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile
and “Air Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices
when installing your unit and provide room air accordingly. Limited air for combustion may result in poor
performance, smoking and other side effects of poor combustion.
If you have any questions with regards to your stove or the above-mentioned information, please feel
free to contact your local dealer for further clarification and comments.
SINCE SHERWOOD INDUSTRIES LTD. HAS NO CONTROL OVER THE INSTALLATION OF
YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED
FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, SHERWOOD
INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE