Enviro ENVIROFIRE 1000, ENVIROFIRE 1600, ENVIROFIRE 1600INS, 2100, ENVIROFIRE 2100 Owner's And Operator's Manual

ENVIROFIRE
WOOD STOVE
MODELS 1000, 1600, 1600INS, 2100
OWNERS AND OPERATORS MANUAL
SHERWOOD INDUSTRIES LTD.
VICTORIA , BRITISH COLUMBIA
V8M-2A3
TABLE OF CONTENTS
PLEASE READ AND SAVE INSTRUCTIONS SAFETY WARNING 2
OPERATING INSTRUCTIONS 3-4
PEDESTAL INSTALLATION
BRICK INSTALLATION
MODEL 1000 6
MODEL 1600 INSERT 7
MODEL 2100 8
FREESTANDING INSTALLATION
MOBILE HOME INSTALLATION
FIREPLACE INSERT INSTALLATION
HOW IT WORKS
SPECIFICATIONS
DOOR INSTALLATION
OPTIONAL FAN INSTALLATION (WIRING DIAGRAM)
RATING LABEL COPY
PARTS AND ACCESSORIES
WARRANTY
EXPLODED VIEW
13
13
18
19
5
9-10
11
12
14
15
16
17
PLEASE READ AND SAVE INSTRUCTIONS
SAFETY WARNING
Please read this entire manual before you install and use your new heater. Failure to follow these instructions may result in property damage, personal injury, and even death.
If this appliance is not properly installed, operated and maintained a serious house fire could result. Do not use any makeshift materials during installation.
Never place wood, paper, furniture, drapes or other combustible materials near the stove, or let children or pets touch it when it is hot.
Operate only with the door and ash pan tightly closed and burn wood directly on the stove floor. Do not operate if the door glass is broken or a gasket is missing or damaged. Do not alter the combustion air control valves. Dangerous overfiring could occur which could ignite creosote in the chimney or cause a house fire.
At least 12 sq. In. (77.4 sq. Cm) of fresh outside air should be admitted into the room or directly to the stove through a 4” in. (10.16 cm) diameter pipe. It would be dangerous to operate the stove with the combustion-air inlet closed.
Do not burn coal or charcoal as there is danger of carbon monoxide being produced. Do not use chemical fluids to start or re-fresh the fire. Do not burn garbage or flammable fluids such as gasoline, grease, naphtha or engine oil. Never let the stove become hot enough to get any part red or glowing red.
Burning wet unseasoned wood could cause excessive creosote accumulation. When ignited it could cause a chimney fire that could result in a serious house fire.
Do not use grates, andirons or any other methods to support or raise the fire up off the hearth of the appliance.
2
OPERATING INSTRUCTIONS
STARTING:
Place crumpled paper on the stove floor and cover with kindling. Open the draft fully and ignite. Hold the door slightly a jar for a few minutes and then close tightly. After the wood is burning brightly add more dry wood and, when the fire is hot, use the draft control to adjust the burn rate. This limits the amount of combustion air entering the fuel chamber and can be adjusted from a low burn rate with the handle fully in, to a fast burn with the handle fully out. Do not allow any part of the appliance or the components to become red or glowing red. This is the sign that the unit is in an overfire condition.
FIRST START:
When first installed, the chimney, firebricks and steel are cold and it usually takes several hours on a fairly high burn for them to become hot and dry enough for the stove to function well. The paint will smell a little for the first time or two as it cures. You may wish to open a door or window to eliminate the smell.
DRAFT CONTROL:
Located on the front of the stove just below the ash sill is the Slider Air Damper. This damper will control the amount of air to the fire. Pull this control all the way out when first starting the stove. Once the fire has been established you may adjust this control to set the burn rate of the fire. If this damper is closed at first start up the fire will burn very slowly and could soot the appliance.
FUEL:
Both hardwood and softwood burn well in this stove. Both woods contain about 8,000 BTUs per pound, but hardwood is generally denser, will weigh more per cord, and burns a little slower and longer. Cutting firewood so that it will fit vertically, front to back, makes it easier loading and less likely for the fuel to roll on the glass. Except for a cold start, there is no need to crisis-cross the logs. Ideal lengths would be about 12 “ for models 1000, 16.5” for model 1600, 21 “ for model 2100. Burn only dry, seasoned wood. It produces more heat and less soot or creosote. Freshly cut wood has about 50% moisture. A ten pound log contains 5 pounds of water. To season firewood split and stack it so that air can get to all parts of the wood. Burn beach wood only if its salt content has been washed away in a season of rain and then the wood dried. When refueling open the door slowly to prevent smoke spillage.
FOR MAXIMUM EFFICIENCY:
When the stove is hot, load it fully to the top of the door opening, and burn at medium low settings. When the fuel is mostly consumed, leaving a bed of red coals, repeat the process. Maximum heat for minimum fuel occurs when the stovetop temperature is between 250° F (120° c) and 550° F (290° c). The bricks will be nearly all white, the glass mostly clear. The most likely causes of dirty glass are: not enough fuel to get the stove thoroughly hot, burning green or wet wood, closing the draft until there is insufficient air for complete combustion, or a weak chimney draw. Indeed, the whiteness of the bricks and the cleanness of the glass are good indicators of the stove operating efficiently.
USE A LONG PAIR OF GLOVES (BARBECUE GLOVES) WHEN FEEDING THE FIRE. BECAUSE THESE STOVES BURN AT THE FRONT THEY ARE CLEAN AND EFFICIENT, BUT THEY ARE ALSO VERY HOT AND GLOVES ARE USEFUL. KEEP A SMALL STEEL SHOVEL AND WHISK NEARBY FOR MOVING A LOG OR LIFTING A FALLEN EMBER AND FOR KEEPING THE HEARTH CLEAN.
FANS:
All models have been approved for operation with or without the optional fans supplied by the manufacturer. On medium or high burns, using a fan will increase the heat transfer slightly. Route the power supply cord along the floor behind the stove where it will remain cool.
3
DISPOSAL OF ASHES:
If you let the ashes accumulate two or three inches on the floor they tend to burn themselves up. Open the small trap door located on the floor of the unit. Push the ashes that have accumulated into the hole were the ashes would drop into the ash pan. Ensure that the trap door is closed properly before relighting the unit. When necessary put the ashes in a metal container with a tightly fitting lid. Place the closed container on a non­combustible floor, well away from combustible materials. If the ashes are to be buried in soil or otherwise locally dispersed, keep them in a closed container until all cinders have cooled. If your model has an ash pan, be sure to latch the ash pan tightly when finished. Small amounts of cold wood ash can be used in the garden or compost.
CLEANING AND REPLACING THE GLASS:
Normally a hot stove will keep the glass clean, but if you must clean the glass, use a soft cloth with no abrasive and clean only when cold. Never strike or slam the door, hit the glass or let burning wood rest against it. If the glass cracks when the fire is burning, do not open the door until the fire is out and do not operate the stove again until the glass has been replaced, preferably by your dealer. To remove the door, open and lift. To replace the glass, remove the steel retaining clips and all loose glass. Replace only with Neoceram 5 mm glass 16.61” (422 mm) x 10.63” (270 mm) and wrap the edges with 0.125” (3.2 mm) x 0.5” (13 mm) self-adhesive fiberglass gasket.
FIRE EXTINGUISHER AND SMOKE DETECTION:
All homes with a solid fuel burning stove should have at least one fire extinguisher in a central location known to all in the household, and at least one smoke detection devise in the room containing the stove. If it sounds the alarm, correct the cause but do not deactivate or relocate the smoke detection devise.
CREOSOTE- ITS FORMATION AND REMOVAL:
When wood is burned slowly, it may produce tar and other vapors that combined with moisture form creosote. These vapors condense in the relatively cooler chimney flue of a slow burning fire, and if ignited, make an extremely hot fire. So, the smoke pipe and chimney should be inspected bi-weekly during the heating season to determine if a build-up has occurred. If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
CHIMNEY OR RUN AWAY FIRE:
1. Call local fire department (or dial 911)
2. Close the draft fully
3. Examine flue pipes, chimney, attic, and roof of the house, to see if any part has become hot enough to catch
fire. If necessary spray with fire extinguisher or water from the garden hose.
4. Do not operate the stove again until you are certain the chimney and its lining have not been damaged.
MAINTENANCE:
At the end of each heating season clean the chimney and the smoke pipe. If soot has accumulated above the top baffle bricks, remove, clean, and then replace them. If the secondary air tube is badly eroded, replace it. Replace
worn door gaskets and broken bricks as needed.
SYSTEM REGULARLY CAN RESULT IN A CHIMNEY FIRE, WHICH COULD DAMAGE THE CHIMNEY OR CAUSE A HOUSE FIRE.
FAILURE TO INSPECT AND CLEAN YOUR CHIMNEY
4
PEDESTAL AND LEG INSTALLATION
Please read and understand these instructions before installing ash pan and leg option.
Failure to follow these instructions carefully could cause personal injury or property damage. All screws are pre installed on the base of the unit.
PEDESTAL
Remove the bricks from the unit before starting.
Loosen the two carriage bolts that secure the unit to the pallet. Slide the pallet towards the front to release carriage bolts from the key holed slots in the unit. Place the unit on the pallet on its back.
Slide the pedestal assembly over the bolts located on the base of the unit using the key holed slots provided.
Tighten all four bolts ensuring the pedestal is properly aligned to the edges of the unit.
Ensure that the gasket material is properly sealed before continuing.
Stand the unit on the pedestal and set the unit in the location ready for installation.
If fresh air supply is being supplied from the bottom of the unit please install the cover plate supplied to the rear of the pedestal covering the 4” inch hole.
LEGS AND ASH PAN
Place the unit on the pallet on its back.
Slide the ash pan assembly over the bolts using the key holed slots provided and tighten all four bolts.
Ensure that the gasket material is properly sealed before continuing.
Carefully remove the cast iron legs from the packaging and secure each leg with two bolts provided.
Secure all four legs, push the leg towards the center of the stove and align the legs with the outer edges of the firebox.
Stand the unit on the legs and set the unit in the location ready for installation
5
MODEL 1000 BRICK PLACEMENT:
COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.
1. Place the bottom layers of the sides and back of the firebox.
2. Place the floor bricks. The spaces between the bricks will soon fill with ashes.
3. Finish the sides and back ready to accept the top, ceiling bricks.
4. On the right and left sides, leave the front. top brick out and install this brick last. Start with a 3” wide brick first,
lift this brick up and rest the brick on the center baffle plate and the top of the side bricks, make sure that it is slid all they way to the back of the stove. Place a full width brick next, and then place another full width brick on the top so that all the joints are staggered. Complete both sides of the ceiling bricks in this manner.
5. Install the last two bricks in the right and left side, uppermost front corners.
6. Make sure that all bricks are secure before starting a fire in this unit.
REMOVE CEILING BRICKS AND CLEAN ABOVE THEM ONCE A
YEAR. REPLACE ANY BROKEN BRICKS
WHEN REPLACING BRICKS USE ONLY CLAYBURN TYPE FIRE BRICKS.
TOTAL BRICKS:
25- FULL SIZE BRICKS (9” LONG X 4.5” WIDE X 1.25” THICK) (22.86 CM LONG X 11.43 CM WIDE X 3.175 CM THICK)
4- PARTIAL BRICKS ( 9” LONG X 3” WIDE X 1.25” THICK) ( 22.86 CM LONG X 7.62 CM WIDE 3.175 CM THICK)
3- 1/2 BRICK FOR ASH DUMP (4.5 “ LONG X 4.5“ WIDE X 1.25” THICK) (11.43 CM LONG X 11.43 CM WIDE X 3.175 CM THICK)
6
MODEL 1600 BRICK PLACEMENT:
COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.
1. Place the bottom layers of the sides and back of the firebox.
2. Place the floor bricks. The spaces between the bricks will soon fill with ashes.
3. Finish the sides and back ready to accept the top, ceiling bricks.
4. On the right and left sides, leave the front. top brick out and install this brick last. Start with a 3” wide brick first,
lift this brick up and rest the brick on the center baffle plate and the top of the side bricks, make sure that it is slid all they way to the back of the stove. Place a full width brick next, and then place another full width brick on the top so that all the joints are staggered. Complete both sides of the ceiling bricks in this manner.
5. Install the last two bricks in the right and left side, uppermost front corners.
6. Make sure that all bricks are secure before starting a fire in this unit.
REMOVE CEILING BRICKS AND CLEAN ABOVE THEM ONCE A
YEAR. REPLACE ANY BROKEN BRICKS
WHEN REPLACING BRICKS USE ONLY CLAYBURN TYPE FIRE BRICKS.
TOTAL BRICKS:
35- FULL SIZE BRICKS (9” LONG X 4.5” WIDE X 1.25” THICK) (22.86 CM LONG X 11.43 CM WIDE X 3.175 CM THICK)
4- PARTIAL BRICKS ( 9” LONG X 3” WIDE X 1.25” THICK) ( 22.86 CM LONG X 7.62 CM WIDE 3.175 CM THICK)
1- 1/2 BRICK FOR ASH DUMP (4.5 “ LONG X 4.5“ WIDE X 1.25” THICK) (11.43 CM LONG X 11.43 CM WIDE X 3.175 CM THICK)
7
Y
MODEL 2100 BRICK PLACEMENT:
COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING BRICKS.
1. Place the bottom layers of the sides and back of the firebox.
2. Place the floor bricks. The spaces between the bricks will soon fill with ashes.
3. Finish the sides and back ready to accept the top, ceiling bricks.
4. On the right and left sides, leave the front. top brick out and install this brick last. Start with a 3” wide brick first,
lift this brick up and rest the brick on the center baffle plate and the top of the side bricks, make sure that it is slid all they way to the back of the stove. Place a full width brick next, and then place another full width brick on the top so that all the joints are staggered. Complete both sides of the ceiling bricks in this manner.
5. Install the last two bricks in the right and left side, uppermost front corners.
6. Make sure that all bricks are secure before starting a fire in this unit.
REMOVE CEILING BRICKS AND CLEAN ABOVE THEM ONCE A
EAR. REPLACE ANY BROKEN BRICKS
WHEN REPLACING BRICKS USE ONLY CLAYBURN TYPE FIRE BRICKS.
TOTAL BRICKS:
39- FULL SIZE BRICKS (9” LONG X 4.5” WIDE X 1.25” THICK) (22.86 CM LONG X 11.43 CM WIDE X 3.175 CM THICK)
8- PARTIAL BRICKS ( 9” LONG X 3” WIDE X 1.25” THICK) ( 22.86 CM LONG X 7.62 CM WIDE 3.175 CM THICK)
3- 1/2 BRICK FOR ASH DUMP (4.5 “ LONG X 4.5“ WIDE X 1.25” THICK) (11.43 CM LONG X 11.43 CM WIDE X 3.175 CM THICK)
8
FREESTANDING
INSTALLATION:
CHIMNEY:
Vent the stove into a clean, lined, approved masonry chimney in good condition, conforming to local building codes or a listed 6” factory built chimney suitable for use with solid fuels and conforming to, ULC-S629 in CANADA or UL­103HT in the U.S.A.. Connect the stove to this chimney with a short and straight 6” (150 mm), 25 gauge or heavier, single wall black or blued steel smoke pipe. Connection to all masonry chimneys must be a metal or masonry thimble cemented in place. All smoke pipe must slope upwards, all connections must be tight and secured with three sheet metal screws equally spaced. The smoke pipe length should not exceed 40% of the chimney height above the stove.
A non-combustible floor protector is required under all freestanding units. The floor protection must extend 18” (457 mm) in front of the unit and 8” (203 mm) to each side. When venting into a masonry chimney the floor protector must be installed directly below the chimney vent and 2” (50.8 mm) on either side of the chimney vent.
DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*
MODEL 1000 MODEL 1600 MODEL 2100 MODEL 1000 MODEL 1600
DOUBLE WALL
PIPE**
DOUBLE WALL
PIPE**
A. SIDE TO UNIT 19 “ (485 MM) 20” (510 MM) 22” (560 MM) 14” (355 MM) 11” (280 MM)
B. REAR TO UNIT 10” (2556 MM) 12” (300 MM) 12” (300 MM) 6” (150 MM) 4” (101 MM)
C. CORNER TO UNIT 6” (150 MM) 6” (150 MM) 8” (200 MM) 2” (50 MM) 6” (150 MM)
D. SIDE TO COLLAR 28” (710 MM) 29” (735 MM) 31” (790 MM) 23’ (585 MM) 20” (508 MM)
E. REAR TO COLLAR 13” (330 MM) 16.5” (420 MM) 16.5” (420 MM) 9” ( 230 MM) 8.25” (210 MM)
F. CORNER TO COLLAR 16” (405 MM) 16.5” (420 MM) 19 “ (485 MM) 11.5” (290 MM) 15.5” (394 MM)
CAUTION: AN UN INSULATED SMOKE PIPE MUST NOT PASS THROUGH AN ATTIC, ROOF SPACE,
CLOSET OR SIMILAR CONCEALED SPACE, OR THROUGH A FLOOR, CEILING, WALL, OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTION.
*ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY.
**DOUBLE WALL: IN CANADA:
IN U.S.A.: ANY HT-103 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING
ANY ULC-629 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING
LISTED DOUBLE WALL VENT CONNECTOR.
LISTED DOUBLE WALL VENT CONNECTOR.
9
OUTSIDE AIR:
A 4” (10.16 cm) fresh air adapter kit is available. This adapter can be installed either
on the back pedestal or through the floor under the pedestal.
Place the 1/4” mesh screen between the fresh air adapter and the body of the
pedestal. (AS SHOWN)
NOTE:
Fresh air connection to the unit must be a non combustible pipe. (Example: 4” (10.16 cm) single wall aluminum flex pipe)
NOTE:
REMOVE THE 4” KNOCK OUT ON THE REAR OF THE
PEDESTAL IF ROOM AIR IS TO BE USED FOR COMBUSTION AIR
Pedestal
rear
ALCOVE INSTALLATION;
Model 1000
Model 1600 May be installed with double wall pipe in an alcove up to 30” (76 cm) deep
and at least 70” (178 cm) high and a minimum width of 48” (122 cm)
May be installed with double wall pipe in an alcove up to
4 ft. (1.2 m) deep and at least 7 ft. (2.13 m) high: sides 14” and rear 6”.
FLOOR PROTECTION:
If a stove is installed on a combustible floor, it must have a pedestal attached and be on a NON COMBUSTIBLE hearth pad extending at least 8” (200 mm) to each side, and 18” (455 mm) to the front as indicated below.
TO INSTALL A LISTED, FACTORY BUILT CHIMNEY.
1. Set floor protector and stove in location in accordance with the clearances
required above (see previous page).
2. Mark the position for the ceiling hole by using a plumb bob.
3. Move this location, if necessary, to avoid floor joists, ceiling rafters while
still maintaining required clearances. (see manufacturer’s label on page 15 or the clearances to combustibles on page 8)
4. Mark the hole for the outside air kit.
5. Move the stove out of the way.
6. Cut a pilot hole in the ceiling.
7. Cut a hole for the ceiling penetration components and frame in the sides of
the hole in both the ceiling and roof. Check, and follow chimney manufacturer’s instructions for all of these steps.
8. Install the support box and chimney through the roof. Install the slip section
for the chimney connector.
9. Slip the roof flashing over the chimney and secure to the roof, being
careful to keep the pipe centered in the opening. To meet the code, the chimney must extend above the roof at least 3 FT. (91.44 CM), and 2 FT. (60.9 CM) above any area of the roof, within 10 FT. (304.8 CM) of the end of the chimney.
10. Be sure all pieces including outside rain cap, flange, collar and pipe are
installed and then place the stove back into position.
11. Install the smoke pipe with the lower (crimped) edge of the pipe inside
the smoke collar. Any creosote formed will then run back down into the stove. All connections must be tight and secured with three sheet metal screws equally spaced.
12. Also install an outside air flex pipe to the stove.
10
MOBILE HOME INSTALLATION
SPECIAL REQUIREMENTS: Pedestal models 1000 and 1600 are approved for mobile homes. All freestanding
installation requirements on the preceding page plus the following must be met:
VENTING:
In Canada: Any ULC-629 listed chimney system with the accompanying double wall vent connector. In U.S.A.
Any HT-103 listed chimney system with the accompanying double wall vent connector. Do not connect a listed chimney of one manufacture with a listed double wall connector from another manufacture. These connectors must be installed in accordance with the manufacturer’s instructions. Use only specified components. The chimney and pipe must extend at least 10-ft. (2.4m) above the stove and 3-ft. (.9 m) above the highest point of the roof. (RECOMMENDED CHIMNEY HEIGHT 12’ FEET) Install a rain cap with spark arrestor at the top that will not impede the smoke exhaust. The chimney must be supported at the ceiling or roof so that its weight will not sit on
the stove. Seal with silicone to maintain vapor barrier at the chimney and outside air penetrations. CAUTION:
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
OUTSIDE AIR :
Connection from the stoves air intake to the outside is mandatory either through a hole in the wall not higher than the stoves bottom, or through a hole in the floor beneath the pedestal using the fresh air adapter provided. If the air intake is through the floor, the hole in the pedestal back must be closed with the sheet metal cover provided. Avoid cutting any floor joists, wall studs, electrical wiring or plumbing. Seal around the outside air pipe with insulation to prevent drafts. Also install a 1/4” mesh rodent or pest screen in the end of fresh air pipe. Fresh air connection must be of a non combustible material (example: 4” 10.16 cm flexible aluminum single wall pipe.) Fresh air could also be supplied from a vented
crawlspace
The pedestal must be firmly bolted to the floor using 1/4” bolts. Be sure to replace any insulation or panels removed when fastening the bottom nuts.
If room air starvation occurs because the air intake is blocked with ice, leaves etc. Or because the stove door was left open, or due to a strong exhaust fan operating, dangerous fumes could be sucked into the room.
IN SOME AREAS IT MAY BE REQUIRED TO ELECTRICALLY GROUND THE STOVE. When this unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a grounding rod. Manufactured (Mobile) home installation must be in accordance with the Manufactured Home Construction and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A
WARNING: DO NOT INSTALL IN A MOBILE HOME SLEEPING ROOM.
11
,(MOBILE HOMES ONLY)
MODEL 1600 INS FIREPLACE INSERT
Unless you are experienced, we recommend installation by your dealer or a professional installer.
Install only in a masonry fireplace at least 25” (635 mm) wide, 22” (560 mm) high and 14” (356 mm) deep with an approved lined chimney at least 15 ft (4.6 m) high, both of which have been constructed in accordance with the building code. Be sure the fireplace and chimney are clean and sound without any cracks or loose mortar. Do not remove any bricks or mortar from the fireplace.
1. Remove any fireplace damper or fasten in a
permanent open position.
(IN CANADA)
2. The stove is vented with a 6” stainless steel liner
that goes directly to the top of the chimney and is covered with a rain cap. The chimney top is sealed with a flashing or steel plate that supports the weight of the chimney liner. The installation must conform to the liners manufacturer’s instructions.
This fireplace must be installed with a continuous liner of 6” diameter (CANADA ONLY) extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the class 3 requirements of CAN/ULC-S635, standard for lining systems for existing masonry or factory built chimneys and vents, or CAN/ULC-S640, Standards for lining systems for new masonry chimneys.
(IN U.S.A.)
The appliance when installed, must follow local building codes, in the absence of local building codes, with the current NFPA 211 Standard for Chimneys, fireplaces, vents, and Solid Fuel Burning Appliances
Screw or Nail the metal plate provided form the manufacture to the inside of the fireplace. METAL TAG: “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.”
Minimum clearances to a unshielded side wall: 17” (430 mm) Minimum clearances to a unshielded mantle: 28” (710 mm) Minimum top facing clearance: 28” (710 mm) Minimum side facing clearance: 1” ( 25 mm)
If there is a combustible floor in front of the masonry fireplace, the fireplace insert must be 8” (205 mm) above the combustible floor, and floor protection must be provided 18” (455 mm) in front of the fireplace insert and 8 “(205 mm) to each side of the unit.
REQUIRED CLEARANCES TO COMBUSTIBLES FROM INSERT:
12
HOW IT WORKS
SPECIFICATIONS:
MODEL 1000 MODEL 1600 MODEL 1600fpi MODEL 2100
WIDTH X DEPTH
24 X 21”
(.61 X .53 M) HEIGHT ON PEDESTAL 33 “ (.83 M) 33 “ (.83 M) N/A 33 “ (.83 M) HEIGHT OF BODY 22” (.56 M) 22” (.56 M) 22” (.56 M) 22” (.56 M)
FUEL CHAMBER DEPTH X WIDTH X HEIGHT
CAPACITY
*APPROXIMATE HEATING AREA
** EPA OUTPUT RATING
12.5 X 18 X 12”
(.3 X .46 X .3 M)
1.7 CU. FT. (.048 M
3
)
1000 SQ. FT.
(85 M 2)
11700 to 32700
BTU/Hr
* DURATION ON LOW BURN 5 TO 7 HOURS 7 TO 9 HOURS 7 TO 9 HOURS 9 TO 11 HOURS
WEIGHT WITHOUT BRICKS
WEIGHT OF BRICKS
311 LBS (141
KG)
63.58 LBS (28.9 KG)
E.P.A. EMISSIONS 4.1 G/HR 3.5 G/HR 3.5 G/HR 2.9 G/HR SURROUND PANELS
(STANDARD SURROUND)
(OVERSIZE SURROUND)
*FIGURES WILL VARY CONSIDERABLY WITH FUEL AND CONDITIONS. ** E.P.A. OUTPUT IS CALCULATED FROM A LOAD OF FIR AVERAGED FROM START UNTIL ENTIRELY
CONSUMED. THE ACTUAL HEAT OUTPUT WITH REFUELING IS VERY MUCH GREATER.
CERTIFICATION: THESE STOVES HAVE BEEN TESTED AND LISTED by INTERTEK (ITS) (WH). TO
STANDARDS. CSA B366.2/ULC-S627, ULC-S628-M93, UL 1482-1994, MODELS 1000 AND 1600 FREESTANDING UNITS HAVE BEEN TESTED AND LISTED FOR USE IN MOBILE HOMES.
24 X 25.5”
(.61 X ..64 M)
17 X 18 X 12”
(.42 X .46 X .3 M)
2.3 CU. FT. (.065 M 3)
1600 SQ. FT.
(150 M 2 )
11500 to 33600
BTU/Hr
356 LBS (161
KG)
83.38 LBS (37.9 KG)
24 X 25.5”
(.61 X ..64 M)
17 X 18 X 12”
(.42 X .46 X .3
M)
2.3 CU. FT. (.065 M 3)
1600 SQ. FT.
(150 M 2 )
11500 to 33600
BTU/Hr
337 LBS (152
KG)
83.38 LBS (37.9 KG)
40” X 28”
101 X 71 CM
46” X 33”
117 X 84 CM
24 X 30”
(.61 X .76 M)
21.5X 18 X 12”
(.53 X .46 X .3 M)
3.1 CU. FT. (.082 M 3)
2100 SQ. FT.
(200 M 2 )
11800 to 34000
BTU/Hr
414 LBS (187
KG)
103.18 LBS (46.9 KG)
13
DOOR INSTALLATION
Remove the door from the packaging. Inspect the door assembly for damage. DO NOT USE DOOR IF GLASS IS BROKEN.
Place the door assembly on the two hinge pins mounted on the body of the unit. Open and close the door, applying pressure down, to ensure the door assembly is properly seated on the hinges.
NUT
CAST LATCH
WASHERS X 2
SPRING WASHER
FERAL
HANDLE
CLOSE THE DOOR
ASSEMBLY AND TURN
THE DOOR HANDLE
DOWNWARDS UNTIL
DOOR IS TIGHT
Thread slider damper spring handle onto slider damper control.
14
OPTIONAL FAN INSTALLATION
The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.
CAUTION
Label all wires
prior to
disconnection
when servicing
controls. Wiring
errors can cause
improper and
dangerous operation. Verify proper operation
after servicing.
1) Remove the fan assembly from the box and
inspect for any damage to the assembly.
2) Remove the metal knock out on the rear of the appliance.
3) Install two screws into the top two holes. Place the blower assembly over these two screws and tighten. Install the two bottom screws and tighten.
4) Plug the fan assembly in and check for proper operation.
DO NOT cut or remove the grounding prong from the plug. Also do not route the power cord beneath the heater.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS.
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged into a properly grounded three-prong receptacle.
This is a basic wiring diagram for the option fan installation. Models 1000, 1600, 2100 Freestanding units only.
1) Plug the fan assembly into a three
prong (grounded) receptacle.
2) Turn the fan controller to the desired
setting.
3) Once the unit has reached operating
temperature, the fan temperature sensor will turn the fan on automatically.
4) When the unit cools down the fan
temperature sensor will shut the fan off automatically.
WIRING DIAGRAM
15
LISTED SOLID FUEL SPACE HEATER SERIAL NO.
DO NOT REMOVE THIS LABEL
WH-
MODEL: 1000 1600 2100 1600 INS
MODEL 1000 SUITABLE FOR USE IN MOBILE HOMES.
CERTIFIED FOR CANADA AND THE U.S.A. REPORT NO. J99011443-231 TESTED TO CSA B366.2/ULC-S627, ULC-S628-M93, UL-1482-1994 REPORT NO. 6385
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. USE 6 IN. / 150 MM DIAMETER MINIMUM 24 MSG BLACK OR 25 MSG BLUED STEEL CONNECTOR LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY. SEE LOCAL BUILDING CODE AND MANUFACTURER’S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING. MINIMUM CLEARANCES FROM HORIZONTAL CONNECTOR AND CEILING (18 IN./ 455 MM) DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE U.S.A. ONLY.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
RESIDENTIAL INSTALLATIONS USING SINGLE WALL CONNECTOR. WITH ANY ULC-S629 LISTED CHIMNEY IN CANADA , AND
SIDE WALL TO UNIT A BACK WALL TO UNIT B CORNER TO UNIT C SIDE WALL TO CONNECTOR D BACK WALL TO CONNECTOR E CORNER TO CONNECTOR F
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATIONS: MODELS 1000 AND 1600
IN CANADA: ANY ULC-629 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING DOUBLE WALL VENT CONNECTOR IN U.S.A.: ANY HT-103 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING DOUBLE WALL VENT CONNECTOR
SPECIFIED CLEARANCES APPLY AND UNITS MAY BE INSTALLED IN CONVENTIONAL HOMES IF SPECIFIED CONNECTORS ARE USED.
SIDE WALL TO UNIT A BACK WALL TO UNIT B CORNER TO UNIT C SIDE WALL TO CONNECTOR D BACK WALL TO CONNECTOR E
CORNER TO CONNECTOR F MODEL 1000 MAY BE INSTALLED IN AN ALCOVE: ALCOVE DEPTH, 4 FT. /1.22 M, HEIGHT 7 FT. 2.13 M MODEL 1600 MAY BE INSTALLED IN AN ALCOVE: ALCOVE DEPTH 30” (76 CM) HEIGHT 70”(178 CM) WIDTH 48” (122 CM) ROOM HEATER, SOLID FUEL TYPE, SUITABLE FOR MOBILE HOMES
ANY UL 103 HT LISTED CHIMNEY SYSTEMS IN THE U.S.A.
MODEL :1000 MODEL: 1600 MODEL: 2100
19 IN. / 485 MM 10 IN. / 255 MM
6 IN. / 150 MM 28 IN. / 710 MM 13 IN. / 330 MM 16 IN. / 405 MM
14 IN./ 355 MM 6 IN. / 150 MM
2 IN. / 50 MM
23 IN. / 585 MM
9 IN. / 230 MM
11.5 IN. / 290 MM
20 IN. / 510 MM 12 IN. / 305 MM
6 IN. / 150 MM
29 IN. / 735 MM
16.5 IN. / 420 MM
16.5 IN. / /420 MM
MODEL 1000
22 IN. / 560 MM 12 IN. / 305 MM
8 IN. / 205 MM
31 IN. / 790 MM
16.5 IN. / 420 MM 19 IN. / 485 MM
MODEL 1600
11 IN. / 280 MM
4 IN. / 101 MM 6 IN. / 153 MM
20 IN. / 508 MM
8.25 IN. / 210 MM
15.5 IN. / 394 MM
If a stove is installed on a combustible floor, it must have a pedestal attached and be on a NON COMBUSTIBLE hearth pad extending at least 8” (200 mm) to each side, and 18” (455 mm) to the front
MODEL 1600 INS MAY BE INSTALLED AS AN INSERT IN A MASONRY
FIREPLACE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURE TO UNIT)
ADJACENT SIDE WALL A MANTLE B TOP FACING C SIDE FACING D
HEARTH EXTENSION MUST BE RAISED (F) 8 IN. / 205 MM ABOVE A SURROUNDING COMBUSTIBLE FLOOR.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A NON-COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN. 455 MM TO THE FRONT OF THE UNIT AND (F) 8 IN. / 205 MM TO THE SIDES
OPERATE ONLY WITH THE DOOR AND ASH PAN CLOSED. ONLY OPEN DOOR TO FEED FIRE. FOR USE WITH SOLID WOOD FUELS ONLY. DO NOT
USE GRATE OR ELEVATE-FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE, DO NOT OBSTRUCT COMBUSTION AIR OPENINGS.. IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY FREQUENTLY-UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHING AND OTHER COMBUSTIBLES WELL AWAY FROM HEATER. REPLACE GLASS ONLY WITH CERAMIC GLASS. OPTIONAL COMPONENTS: FAN, ELECTRICAL RATING 115V, 60 Hz 1 AMP. ROUTE CORD AWAY FROM HEATER.
MANUFACTURED BY:
MODEL 1600 INS 17 IN. / 430 MM
28 IN. / 710 MM
28 IN. / 710 MM
1 IN. / 25 MM
SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. VICTORIA B.C V8M-2A3
MADE IN CANADA
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURN. READ NAMEPLATE AND INSTRUCTIONS.
CAUTION
16
PARTS AND ACCESSIORIES
PLEASE CONTACT YOUR LOCAL ENVIROFIRE DEALER WHEN REPLACEMENT PARTS ARE REQUIRED.
EF-163 WOOD STOVE PAINTED DOOR EF-164 WOOD STOVE GOLD DOOR EF-165 1600 FPI PANEL SET (REGULAR) EF-166 1600 FPI PANEL SET (OVERSIZE) EF-167 FAN KIT (1000, 1600, 2100, (FREESTANDING ONLY) EF-168 DOOR GASKET EF-169 CLAYBURN BRICKS EF-170 INNER DOOR B WITH GLASS EF-171 SECONDARY AIR TUBE EF-172 AIR SHUTTER EF-173 DOOR HANDLE EF-174 AIR SHUTTER CONTROL HANDLE EF-175 PEDESTAL MODEL 1000 EF-176 PEDESTAL MODELS 1600, 2100 EF-177 ASH PAN GASKET EF-178 ASH PAN LATCH (WOOD ONLY) EF-179 FAN SWITCH EF-180 CONVECTION BLOWER EF-181 POWER CORD EF-182 WIRE HARNESS EF-183 OWNERS AND OPERATORS MANUAL EFW-250 EF 1000 SET OF 4 PAINTED LEGS W / ASH PAN EFW-251 EF 1000 SET OF 4 GOLD LEGS W / ASH PAN EFW-252 EF 1000 SET OF 4 NICKEL LEGS W / ASH PAN EFW-253 ONE PAINTED LEG EFW-254 ONE GOLD LEG EFW-255 ONE NICKEL LEG EFW 256 EF 1000 PEDESTAL EFW-257 EF 1600 / 2100 PEDESTAL EFW-258 CAST IRON DOOR W / GLASS PAINTED EFW-258 CAST IRON DOOR W / GLASS GOLD EFW-260 CAST IRON DOOR W / GLASS NICKEL EFW-261 EF 1000 / 1600 / 2100 FAN KIT EFW-262 REGULAR PANEL SET EFW-263 OVERSIZE PANEL SET EFW-265 EF 1600 / 2100 SET OF 4 PAINTED LEGS W / ASH PAN EFW-266 FRESH AIR KIT EFW-267 EF 1600 / 2100 SET OF 4 GOLD LEGS W / ASH PAN EFW-268 EF 1600 / 2100 SET OF 4 NICKEL LEGS W / ASH PAN
17
WARRANTY
Because of our high standards Sherwood Industries Ltd. can offer a *Lifetime Warranty on all it’s wood products. Covered under this warranty are Cabinet Sides, Tops, Pedestals, Surround Panels, Removable Air Channel, and Chassis. These steel components are covered against manufacture’s defects for 1 year on parts and labor and for parts only for the next 4 years. Please refer to the warranty agreement for specific details on the coverage of your *Lifetime Warranty.
Sherwood Industries Ltd. offers an unlimited lifetime warranty for the secondary air tube (channel) for parts only and labor for the first year.
Sherwood Industries Ltd. does not offer warranty on the following items: Door and Ash Pan gasketing. Firebricks.
(A) The following exclusions apply: GOLD PLATING- Damage caused by scratching, marring, fingerprints, abrasive cleaners, overfiring and
discoloration with age.
GLASS- The use of harsh or abrasive cleaners, striking the glass or surface contaminates.
All claims under this warranty shall be made in writing by your dealer:
WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING
INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM:
To the Dealer
Name, address and telephone number of purchaser and date of purchase.
Date of installation. Name of installer and dealer. Serial number of the appliance. Nature of complaint, defect
or malfunction. Description and part # of any parts replaced.
To the Distributor
Sign and verify that the work and information is correct.
This warranty covers defects in materials and workmanship only if the product has been installed according to the manual’s instructions. If the product is damaged or broken as a result of misuse or mishandling, the warranty does not apply. The warranty does not cover removal and re-installation costs.
Sherwood Industries Ltd. reserves the right to repair or to replace the defective product. The shipping costs are paid by the consumer. All warranties by the manufacture are set forth herein and no claim shall be made against the manufacturer on any oral warranty or representation.
Sherwood Industries Ltd. and its employees or representatives will not assume any damages, either directly or indirectly caused by improper usage, operation, installation, servicing or maintenance of this appliance.
Sherwood Industries Ltd. reserves the right to make changes without notice. Please complete and mail the warranty registration card and have the installer fill in the installation data sheet in the back of the manual for warranty and future reference.
SHERWOOD INDUSTRIES LTD.
6782 OLDFIELD ROAD
SAANICHTON, BRITISH COLUMBIA
V8M-2A3
WEB SITE ADDRESS www.envirofire.biz
9/5/02
18
SET OF FOUR (4) LEGS W/ ASH
PAN
EF 1000
PAINTED -EFW 250
GOLD -EFW 251
NICKEL- EFW 252
EF 1600-2100
PAINTED- EFW-265
GOLD- EFW-267
NICKEL- EFW-269
SPRING
HANDLE
GOLD
10-006
NICKEL
10-007
GLASS
W/ TAPE
10-000
CAST DOOR
W/ GLASS
PAINTED EFW-258
GOLD
EFW-259
NICKEL
EFW-260
DOOR
HANDLE
ASSEMBLY
10-001
SOLID ASH
COVER
EF-196
SLIDER
DAMPER
SPRING
HANDLE
EF-191
SLIDER DAMPER
PLATE
1000, EF-173
1600, 2100 EF-174
ASH PAN
LATCH
EF-060
ASH PAN
LATCH
EF-060
FREESTANDING
PEDESTAL
1000, EFW-256
1600, 2100 EFW-257
FRESH AIR KIT
EF-186
EFW -266
BRICKS
3” X 9” EF-169, A
4.5” X 4.5” EF-169, B
4.5” X 9 EF-169, C
FLAT TOP
CABINET SIDES
SECONDARY
AIR TUBE
EF-171
120° TEMPERATURE
SENSOR
EF-205
CONVECTION
BL0WER
EF-180
FAN
CONTROLLER
EF-179
FAN KIT
EFW 261
STEP TOP
CABINET SIDES
WOOD STOVE
EXPLODED PAGE 1 OF 1 DECEMBER 2001
19