Enviro C-10637, 50-1096 User Manual

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
PAPER.
Sienna
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open ame.
• Do not try to light any appliance.
• Do not touch any electrical switch or use any phone in your building.
• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
This appliance is
only for use with
the type of gas
rating plate. This
appliance is not
convertible for use
with other gases,
unless a certied
kit is used.
WARNING
If the information in this manual is not followed exactly, a re or explosion
may result causing property damage, personal injury or loss of life.
Installation and service must be performed by a qualied installer, service
agency or the gas supplier.
Massachusetts installations (Warning): This product must be installed by a licensed plumber or gas tter when installed within the Commonwealth of Massachusetts. Other Massachusetts code requirements: Flexible connector must not be longer than 36in, shut off valve must be a “T” handle gas cock; only direct vent sealed combustion products are approved for bedrooms/bathrooms; replace dampers must be removed or welded in the open position prior to the installation of a replace insert or gas log.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapours and
liquids in the vicinity of this or any other appliance.
50-1096

Safety Precautions

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:
All ENVIRO gas-red appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual rst. Consult the building authority having jurisdiction to determine the need for a permit prior to commencing the installation.
NOTE: Failure to follow these instructions could cause a malfunction of the replace, which could result in death, serious bodily injury, and/or property damage.
Failure to follow these instructions may also void your re insurance and/or warranty.
GENERAL
Installation and repair should be done by a qualied service person. The appliance should be inspected before the rst use and, at least, annually by a qualied service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative the control compartments, burners and circulating air passageways of the appliance be kept clean.
Due to high temperatures, the appliance should be located out of high trafc areas and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn or clothing ignition.
Young children should be carefully supervised when in the same room as the appliance.
Clothing or other ammable materials should not be placed on or near the appliance.
To prevent injury, do not allow anyone who is unfamiliar with the stove to operate it.
• To prevent injury, if the pilot or pilot and burners have gone out on their own, open the glass door and wait 5 minutes to air out before attempting to re-light the stove.
Always keep the area around these appliances clear of combustible material, gasoline and other ammable liquids and vapours.
These appliances should not be used as a drying rack for clothing or for hanging Christmas stockings/ decorations.
Due to the paint curing on the stove, a faint odor and slight smoking will likely be noticed when the stove is rst used. Open a window until the smoking stops.
Always connect this gas stove to a vent system and vent to the outside of the building envelope. Never vent to another room or inside the building. Make sure the specied vent pipe is used, properly sized and of adequate height to provide sufcient draft. Inspect the venting system annually for blockage and signs of deterioration.
WARNING: Failure to position the parts in accordance with the diagrams in this booklet, or failure to use only parts specically approved with this appliance, may result in property damage or personal injury.
WARNING: Do not operate with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualied service person.
Never use solid fuels such as wood, paper, cardboard, coal, or any ammable liquids, etc., in this appliance.
FOR YOUR SAFETY
Installation and service must be performed by a qualied installer, service agency or gas supplier.
This installation must conform to local codes or, in the absence of local codes, to the current CAN/CGA­B149 installation code (Canada) or National Fuel Gas Code ANSI Z223.1.2 (USA)
2
Do not use this heater if any part has been under water. Immediately call a qualied service technician to inspect the heater and to replace any part of the control or gas control systems that have been under water.
Do not abuse the glass by striking it or slamming the door shut.

Table of Contents

Safety Precautions.....................................................................................................2
Table of Contents......................................................................................................3
Codes And Approvals.................................................................................................4
Specications............................................................................................................5
Rating Label Location......................................................................................5
Dimensions....................................................................................................5
Operating Instructions...............................................................................................7
Pilot Lighting Instructions................................................................................7
Pilot Light.......................................................................................................7
Burner Lighting..............................................................................................8
Turn Off Unit..................................................................................................8
Remote Controls - Optional..............................................................................8
Blower Speed.................................................................................................8
Maintenance And Service...........................................................................................9
Cleaning The Glass.........................................................................................9
Cleaning The Firebox......................................................................................9
Replacing The Glass........................................................................................9
Cleaning The Plated Surfaces...........................................................................9
Fuel Conversion............................................................................................10
Initial Installation.....................................................................................................11
Clearances to Combustibles...........................................................................11
Minimum Fireplace Size.................................................................................12
B-Vent Model................................................................................................12
Automatic Flue Gas Spill Switch - B-Vent Model Only.......................................12
Direct Vent Model.........................................................................................13
Preparing Your Sienna For Installation............................................................13
Venting Fireplace Inserts...............................................................................14
Electrical Requirements.................................................................................15
Gas Line Connection.....................................................................................16
Converting A Direct Vent Fireplace To A B-Vent Fireplace.................................17
Secondary Installation..............................................................................................18
Replacing the Blower.....................................................................................18
Door Removal..............................................................................................19
Installation of Surround Pane........................................................................19
Log Set and Ember Installation......................................................................20
Adjusting Venturi Air Settings........................................................................22
Removing The Brick Panel.............................................................................23
Trouble Shooting.....................................................................................................24
Parts List- Unit Components......................................................................................25
Parts Diagram - Components....................................................................................26
Parts Diagram - Burner.............................................................................................27
Parts List - Options..................................................................................................28
Parts Diagram - Options...........................................................................................29
Warranty.................................................................................................................30
Installation Data Sheet.............................................................................................31
3

Codes And Approvals

DIRECT VENT: This type is identied by the sufx DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.
This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.
BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimney liner kit.
This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.
In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association
guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.
In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certied high altitude
rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).
This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:
VENTED GAS FIREPLACE HEATER (SIENNA BV/DV; NG/LPG)
TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS
CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES
CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY
This ENVIRO SIENNA Fireplace:
• Has been certied for use with either natural or propane gases. (See rating label.)
• Is not for use with solid fuels.
• Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall thermostat. IN USA: see current ANSI Z223.1 for installation instructions.)
• Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.
• Must be properly connected to an approved venting system and not connected to a chimney ue serving a separate solid-fuel burning appliance.
• Is not approved for closet or recessed installations.
IMPORTANT NOTICE (Regarding rst re up): When the unit is turned on
for the rst time, it should be turned onto high without the fan on for the rst 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the rst burn, turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas replace glass cleaner, available at your local ENVIRO dealer.
4

Specifications

339/16"
(852 mm)
331/8"
(841 mm)
21"
(533 mm)
391/2"
(1004 mm)
1411/16"
(374 mm)
175/16"
(439 mm)
273/4"
(705 mm)
261/8"
(663 mm)
151/16"
(383 mm)
301/2"
(775 mm)
205/8"
(523 mm)
2211/16"
(576 mm)
237/16"
(596 mm)
Shown: Direct Vent with
arched surround panel
Flue
Back

RATING LABEL LOCATION:

The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the replace.

DIMENSIONS:

Table 1: Sienna exterior dimensions. (Shaded dimensions shown in Figure 1 & 2.)
Surround Style Distance Direct Vent B-Vent
Arched Surround From Flue To Surround 14
From Back/Sensor To Surround 17
33” x 46” (840 x 1930 mm) Surround
33” x 46” (840 x 1930 mm) Surround with Trim
From Flue To Surround 14 ” (369 mm) 14 ” (365 mm)
From Back/Sensor To Surround 17
From Flue To Trim 13 ” (337 mm) 13
From Back/Sensor To Trim 15
11
/
16” (376 mm) 14
5
/
16” (439 mm) 18 ” (479 mm)
1
/
16” (434 mm) 18
13
/
16” (402 mm) 17 ” (441 mm)
9
/
16” (370 mm)
11
/
16” (474 mm)
1
/
16” (333 mm)
Figure 1: Sienna exterior dimensions; example 1.
5
Specifications
151/16"
(383 mm)
301/2"
(775 mm)
With Trim
333/16"
(343 mm)
Without Trim
33" (338 mm)
205/8"
(523 mm)
223/4"
(577 mm)
2211/16"
(576 mm)
With Trim 461/8" (1171 mm) Without Trim 46" (1168 mm)
21"
(533 mm)
131/16"
(333 mm)
13/8"
(36 mm)
173/8"
(441 mm)
Shown: B-Vent with
33" x 46" (84cm x 193 cm)
surround panel with trim
Flue
Sensor
Figure 2: Sienna exterior dimensions; example 2.
6
1. STOP! Read the safety information above on this label.
2. Turn off all electrical power to this appliance.
3. Turn off the gas control knob clockwise to the off position.
4. Open door. Wait fIve (5) minutes to clear out any gas. Close door. If you smell gas STOP! Follow “B” in the above safety information. If you do not smell gas go to the next step.
5. Find pilot-located to the left under the front log. Turn the gas control knob counter-clockwise to “PILOT”. Push the gas control in fully and hold, keep knob depressed for about 30 seconds after the pilot is lit. Release knob. If pilot goes out, repeat steps 4 through 5.
CAUTION:
Hot while operating. Do not touch, severe burns may result. Keep children, clothing, furniture, gasoline or other flammable vapors away.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A) This appliance is equipped with a pilot, which must be lit by hand by
following these instructions exactly.
B) BEFORE LIGHTING smell all around the appliance area for gas and next to
the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance. Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier, call the fire department.
C) Use only your hand to push in or turn the gas control knob;
NEVER use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D) Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING: this gas valve has a lockout device, which will not allow the
pilot burner to be relit until the thermocouple has cooled. If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot does not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.
6. Turn the gas control knob counter clockwise to the “ON” position. Flip the burner switch to “ON” THEN TURN THE “HI/LOW” knob to the desired setting.
7. Turn on the electrical power to the unit.
TO TURN OFF GAS TO APPLIANCE
1. Flip burner switch to “OFF”
2. Turn the gas control knob clockwise to the “OFF” position.

3. Turn off all electrical power to the appliance if service is to be performed.
CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier. See installation and operating instructions accompanying appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
O
L
I
T
P
TPTH TP TH
IN OUT
H
I
L
O
N
O
F
O
F
L
I
P
T
O



Operating Instructions

For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION
MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.

PILOT LIGHTING INSTRUCTIONS:

PILOT LIGHT:

1. Turn off the gas to the replace. If not recently done, remove the glass and let the unit air out for at least ve (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints
with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING.
2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 4).
3. Start the main burner by turning the gas control knob to ON and then turn the rocker switch to ON. Check that all burner ports have ame.
4. Leak test all gas joints again.
Figure 3. Lighting instruction label.
Figure 4. Pilot ame.
7
Operating Instructions



For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating

BURNER LIGHTING:

A) Make sure the pilot is lit. B) Turn gas control knob COUNTER CLOCKWISE to ON. C) Flip the burner switch to ON. D) Turn HI/LO knob to the desired ame height. E) Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.
Figure 5. Control panel.

TURN OFF UNIT:

Flip switch to OFF to turn off burners only.
If the replace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. If the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the rst time, it should be turned onto high, with the fan OFF, for the rst two to four hours. This will cure the paint, logs, gasket material, and other products used in the manufacturing process. It is advised that a door or window be opened, as the unit will start to smoke, which can irritate some people. After the unit has gone through the rst burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas replace glass cleaner, available at your local Enviro dealer. See “DOOR REMOVAL” and “CLEANING THE GLASSsections.

REMOTE CONTROLS - OPTIONAL:

This replace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the replace for the majority of the time, leave the ON/OFF switch (on the control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall thermostat for operation guidelines.

BLOWER SPEED:

The blower will come on only when the replace is up to temperature (approximately 20 minutes). Turning the fan control knob will change the speed of the fan. To turn the blower off, turn the knob COUNTER-CLOCKWISE until it “clicks” off (Figure 6).
It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.
Figure 6. Fan control.
8

Maintenance And Service

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specically approved with this appliance, may result in property damage or personal injury.
At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot ame should be blue with little or no yellow on the tips.
The venting system must be periodically examined; it is recommended the examination is done by a qualied agency.

CLEANING THE GLASS:

When the replace is cool, remove the face of the replace along with the glass door. See “DOOR REMOVAL“. Check the gasket material on the back of the glass, making sure that it is attached and
intact.
During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all replaces. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave a slight lm behind the glass, a temporary problem. The glass will need cleaning after the replace has cooled off from the rst burn and about two weeks after rst burn. Use
a mild glass cleaner and a soft cloth. Abrasive cleaners will damage the glass and plated surfaces. Depending on the amount of use, the glass should require cleaning no more than two or three times a season. Do not clean the glass when it is hot.

CLEANING THE FIREBOX:

Remove the logs carefully, as they are very fragile. Gently remove all the embers and rock wool and place on a paper towel. Vacuum the bottom of the rebox thoroughly. Carefully clean any dust off the logs and remove any lint from the burner and pilot. At this time, inspect the burner pan for cracking or severe warping. If a problem is suspected, contact the dealer. Check the logs for deterioration or large amounts of soot; a small amount on the bottom side of the logs is normal. Replace the logs and embers as in the “LOG SET AND EMBER INSTALLATION section. If new/more embers and rock wool are required, contact your nearest ENVIRO dealer.

REPLACING THE GLASS:

The glass in the replace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see “PARTS LIST). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacement of the glass from the door must be done by a licensed or qualied service person. The glass must be purchased from an ENVIRO dealer. No substitute materials
are allowed.

CLEANING THE PLATED SURFACES:

Painted faces should be wiped with a damp cloth periodically. If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the nish, including cleaners, polish and nger prints. It is important to note that ngerprints and other marks can leave a permanent stain on plated nishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the replace. Never clean the face when it is hot. Do not use other cleaners as they may leave a residue, which can become permanently etched into the surface.
9
Maintenance And Service
TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

FUEL CONVERSION:

Warning: This conversion kit shall be installed by a qualied service agency in accordance with the
manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a re, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualied service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked
as specied in the manufacturer’s instructions supplied with the kit.
Please read and follow these instructions. Also, please read the instruction guidelines provided by S.I.T. on how to remove and install the HI/LO regulator.
Step 1. Carefully inspect all parts supplied with this conversion kit. Step 2. Shut the gas supply off at the shut-off valve. (CAUTION: The
gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.)
Step 3. Remove the glass as shown in the Secondary Installation
section.
Step 4. Change the regulator on the front of the gas valve (follow the
instructions provided by S.I.T.).
Step 5. To change the pilot, simply pull the pilot hood straight up to
access the pilot injector. Using a 5/32 inch Allen key, remove the pilot injector.
Step 6. Install the new pilot injector supplied with this conversion kit. Simply screw the new injector
inside the pilot hood and reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place.
Step 7. Remove the main burner orice with a  inch deep socket. Step 8. Install the new orice supplied. Be sure to put a bead of pipe-thread sealant or approved
Teon tape on the orice before installing into the burner assembly.
Step 9. Reinstall the burner tray, log set, embers, and glass. When re-installing the burner, ensure that
the burner to pilot hood relationship is as shown on Figure 7.
Step 10. Open the shut-off valve at the gas line to the unit. Step 11. Use a small brush to apply a warm soapy water solution to all gas connections (use a half
dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by using an approved pipe thread sealant or approved Teon tape. NEVER USE A NAKED FLAME WHEN TESTING FOR LEAKS.
Step 12. Re-light the replace to ensure proper operation and proper ame appearance. Step 13. MAKE SURE that the sticker provided by S.I.T. is installed, to signify that the valve has been
converted to a different fuel type. Also, make sure that the rating plate has a conversion label to show this unit has been converted to a different fuel type.
Figure 7. Ignitor assembly
beside the burner.
A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE REGULATOR IS THE CORRECT PART. A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER ON THE KNOB Conversion Kit should contain the following: (1) 50% turn down HI/LO regulator with three (3) T-20 Torx screws (1) Pilot injector (1) Main orice (NG #32 DMS; LP #49 DMS) Conversion instructions Labels to show conversion
10