Enviro 170S5FG User Manual

MQL • TABLE OF CONTENTS
2
Product Overview .....................................................................................................................................3
Features and Benefits...............................................................................................................................6
Application Considerations ......................................................................................................................5
Unit Configuration ...................................................................................................................................6
Electric Heat .............................................................................................................................................7
Coil and Filter Data ..................................................................................................................................9
Static Pressure Data ................................................................................................................................10
Fan Notes ................................................................................................................................................13
Fan Performance Data.............................................................................................................................14
Guide Specifications................................................................................................................................25
Metric Conversion Chart..........................................................................................................................28
Features and Options ..............................................................................................................................30
GENERAL NOTES
Some drawings are not shown in this catalog. Please refer to www.enviro-tec.com for complete submittal drawings for your project.
All data herein is subject to change without notice. Refer to www.enviro-tec.com for current catalog and submittal drawings.
Drawings not for installation purposes; refer to IOM manual at www.enviro-tec.com.
ETL Report Number 3017723-001.
MEA Number MEA 107-02-E applies to all units with any combination of chilled water or R-22 direct expansion coils and either hot water coils, steam coils, or electric heat.
ENVIRO-TEC
PRODUCT OVERVIEW • MQL
3
The Perfect Solution for Schools, Hospitals, and Commercial Buildings.
The flexibility of the Model MQL Blower Coil allows you to design the unit to meet the specific project needs. The MQL design allows you to configure draw thru applications in horizontal, vertical, and foot­print-saving arrangements. From basic air handling to the sophisticated isolation room systems required to meet challenging indoor air quality (IAQ), controls, and acoustic (sound sensitive) projects – the Model MQL Blower Coil is your solution!
Standard Features
Modular construction allows for footprint saving arrangements including stacking modules in two-high
configuration.
IAQ galvanized drain pans are double sloped to prevent standing water and minimize microbial growth.
Stainless steel drain pans are available.
Removable access panels for improved accessibility, cleanability, and serviceability. Hinged access doors
with quick action latches are available.
Single point power connection – even with draw thru or blow thru electric heat – simplifies installa-
tion. Fan motors are factory mounted and wired to the junction box.
Available in nine sizes, from 600 to 10,000 CFM.
Internal spring isolation standard on all unit sizes 02 - 17.
Single wall and double wall-galvanized construction are available. Double wall construction enhances
indoor air quality, protects insulation, and provides the ability to clean the inside of the unit.
Optional Features
Factory-packaged blower coils are available with starters or variable frequency drives, factory mounted
and wired. Simply connect power, piping, and ductwork, and the units are ready for operation. An excellent way to minimize installation time, coordination and costs, while increasing reliability.
Quiet, flexible, acoustical discharge plenums may be used for sound sensitive projects.
Exhaust / Return Fan with Economizer Sections for use with IAQ applications (“free” heating and cool-
ing – cost savings for space conditioning).
Customized Options including:
- Direct drive plug fans
- High efficiency filters
- Double wall perforated lining
- External face and bypass dampers
- Inspection windows
ENVIRO-TEC
MQL • FEATURES AND BENEFITS
4
Designed For Maximum Flexibility
The ENVIRO-TEC
®
Model MQL Blower Coil Unit is designed to maximize flexibility of selection and installation.
The unit is also designed to exceed the stringent quality standards of the institutional market, while remaining cost competitive in the light commercial segment of the market.
ENVIRO-TEC
®
Model MQL sets the new standard for quality, flexibil­ity, and competitive pricing.
For the Building Designer: OPTIONAL COMPONENTS MEAN FLEXIBILITY
The extensive variety of standard options available on the MQL is where you find the versatility to fit any HVAC system designer’s needs.
Options include: Mixing boxes with standard low leak dampers, High efficiency filter sections for 2" prefilter and 4" final filter, blow thru electric heat with single point power connection. All electric heat units are listed with ETL as an assembly and carry the cETL label.
High Efficiency motors, starters, disconnects and fusing mean eas­ier coordination between mechan­ical and electrical trades.
Coil options allow for 4 or 6 row cooling coils. Water coils have optional circuiting that can be used to reduce Water Pressure Drop, which may also allow for pipe size reductions and lower material cost. Hot Water or Standard Steam coils may be placed in the Preheat or Reheat position.
All Model MQL blower coils have the option of foil faced insulation.
For the Contractor: L
OWER INSTALLED COST
Model MQL blower coils are shipped completely assembled, reducing field installation time and labor. All units are thor­oughly inspected and tested prior to shipment, eliminating potential problems at startup. Motor wiring is brought to a junction box on the outside of the unit casing, reduc­ing electrical hook-up time.
A wide variety of fan discharge configurations allow for increased flexibility and easier installation on the jobsite, resulting in cost reduc­tions by eliminating expensive elbows, etc.
For the Owner: QU
ALITY PRODUCT
Model MQL blower coil units are built from G60 minimum spangled galvanized steel with a chromate coating. This metal surpasses the ASTM 125 hour salt spray test for corrosion and rust. Standard insu­lation is 1 inch fiberglass insulation which is glued and pin spotted for maximum positive adhesion. Insulation complies with UL 181 and NFPA 90A.
All units, with or without Electric Heat, are ETL listed and labeled. All wiring is in compliance with NEC, assuring safety and quality for the owner.
ENVIRO-TEC
APPLICATION CONSIDERATIONS • MQL
5
Application Considerations
Model MQL blower coil units offer a wide range of application flex­ibility, while maintaining a simple, easy to install unit design. These units are intended to provide comfort cooling and heating within a small footprint. They may be applied in many types of building structures including schools, office buildings, hospi­tals, condominiums, assisted liv­ing facilities, apartments or stores. Applications can be constant or variable volume.
There are many applications in which the MQL product can be utilized. Some examples include:
Constant volume applications
Two-pipe hydronic system for cooling and/or heating
Two-pipe hydronic cooling system with electric heat
Four-pipe system with dedi­cated heating and cooling coils
Direct Expansion (DX) split systems with hydronic heat
Direct Expansion (DX) split systems with electric heat
Variable volume applications
Two-pipe hydronic system for cooling and/or heating.
Two-pipe hydronic cooling system with electric heat.
Four-pipe system with dedi­cated heating and cooling coils.
Acoustics
Control of noise within both occu­pied and unoccupied spaces has become increasingly important to designers and building own­ers/occupants. Proper considera­tion must be given to placement of indoor air conditioning units, particularly in the occupied space.
Inherent flexibility of the fan and coil combination in the vertical configuration allows application in sound-sensitive areas. In such instances, a fan running at low speed with a high capacity coil normally yields satisfactory results. It also may be desirable to select a larger nominal capacity unit and operate it at a less than nominal airflow for further acoustic benefit.
Three phase motors are recom­mended for sound-sensitive appli­cations to avoid potential single phase motor hum. Unit operation in the stall region of the fan curve is not recommended since it may cause unsatisfactory noise levels and excessive unit vibration.
Installation
These floor mounted or ceiling hung units can be installed on a base rail or hanger rods at the cor­ner points. All units have internally isolated fan decks; therefore, flex connections are not required, which will reduce installation costs. One of the most important and basic IAQ issues is condensate management. The first step to ensure trouble-free operation is proper installation. It is very important that the unit be mounted high enough so that the condensate drain from the unit may be properly trapped. Please refer to the MQL IOM Manual at www.enviro-tec.com for specifics on this issue. As with all HVAC sys­tems, these units should be installed according to all applica­ble ASHRAE standards, SMACNA and local code requirements.
Operating Limitations
Units must not be operated above maximum fan speed or unit air­flow as listed in the Fan Performance section of this cata­log. Unit operation at greater than maximum fan speed could drastically reduce bearing life and may result in a catastrophic fail­ure. Operating at greater than the maximum allowable airflow in the cooling mode may result in unsatisfactory operation due to moisture carry over from the coil. In addition, it is often not eco­nomical to operate a unit at its maximum fan speed due to the greater motor power require­ments.
Units with electric heat should not be operated with leaving air tem­perature greater than 104°F, to prevent excessive leaving air tem­peratures and electric heat limit trips. A hydronic (or steam) coil and electric heat should not be operated simultaneously to pre­vent excessive leaving air tem­peratures and limit trips. Electric heat units are equipped with a lockout switch that disables the electric heater if the temperature of the hydronic (or steam) coil is greater than 104°F (40°C).
Water coils must not be operated above a fluid velocity of 8 ft./sec. to reduce the possibility of veloc­ity induced erosion and flow noise. Water coils must not be operated below a fluid velocity of 1 ft./sec. to prevent degraded coil performance caused by laminar flow. These high or low fluid flow rates may not be included in the ARI coil certification.
ENVIRO-TEC
MQL • UNIT CONFIGURATION
6
Position: 1 2 3 456 7 8 9 10
MQL - Module Size Dim. 02 03 04 06 08 10 12 14 17
H - in (mm) 17-3/8 (441) 17-3/8 (441) 17-3/8 (441) 26-3/8 (670) 26-3/8 (670) 26-3/8 (670) 41-3/16 (1046) 41-3/16 (1046) 41-3/16 (1046)
W - in (mm) 28 (711) 34 (864) 42 (1069) 42 (1069) 46 (1168) 56 (1422) 64 (1626) 68 (1727) 80 (2032)
L - in (mm) 5-1/4 (133) 5-1/4 (133) 5-1/4 (133) 5-1/4 (133) 5-1/4 (133) 5-1/4 (133) 5-1/4 (133) 5-1/4 (133) 5-1/4 (133)
SAM Small Access H - in (mm) 22 (559) 22 (559) 22 (559) 30 (762) 34 (864) 34 (864) 44 (1118) 44 (1118) 44 (1118)
SCM Small Coil W - in (mm) 30 (762) 36 (914) 44 (1118) 44 (1118) 48 (1219) 58 (1473) 66 (1676) 70 (1778) 82 (2083)
SFM Small Flat Filters (2" and/or 4" Cartridge) L - in (mm) 15 (381) 15 (381) 15 (381) 15 (381) 15 (381) 15 (381) 15 (381) 15 (381) 15 (381)
MAM Medium Access H - in (mm) 22 (559) 22 (559) 22 (559) 30 (762) 34 (864) 34 (864) 44 (1118) 44 (1118) 44 (1118)
MCM Medium Coil W - in (mm) 30 (762) 36 (914) 44 (1118) 44 (1118) 48 (1219) 58 (1473) 66 (1676) 70 (1778) 82 (2083)
MFM
Med. INTELLITRAC
®
Mix. Box w/Flat Filters (2")
L - in (mm) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762)
MIM
Med. INTELLITRAC
®
Inlet Plenum w/Flat Filters (2")
MMM Medium Mixing Box with Flat Filters (2")
MRM Medium Inlet Plenum with Flat Filters (2")
MVM Medium V-Bank Filters (2")
HFM Horizontal FC Fan H - in (mm) 22 (559) 22 (559) 22 (559) 30 (762) 34 (864) 34 (864) 44 (1118) 44 (1118) 44 (1118)
HPM Horizontal Plug Fan W - in (mm) 30 (762) 36 (914) 44 (1118) 44 (1118) 48 (1219) 58 (1473) 66 (1676) 70 (1778) 82 (2083)
RFM Return FC Fan L - in (mm) 32 (813) 32 (813) 32 (813) 36 (914) 36 (914) 36 (914) 40 (1016) 40 (1016) 40 (1016)
RPM Re turn Plug Fa n
VCM Vertical Coil
VFM Vertica l FC Fa n
MBM Medium Face & Bypas s H - in (mm) 30 (762) 30 (762) 30 (762) 40 (1016) 46 (1168) 46 (1168) 56 (1422) 58 (1473) 58 (1473)
MTM Medium Tall Coil W - in (mm) 30 (762) 36 (914) 44 (1118) 44 (1118) 48 (1219) 58 (1473) 66 (1676) 70 (1778) 82 (2083)
STM Small Tall Coil L - in (mm) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762)
H - in (mm) 22 (559) 22 (559) 22 (559) 30 (762) 34 (864) 34 (864) 44 (1118) 44 (1118) 44 (1118)
W - in (mm) 30 (762) 36 (914) 44 (1118) 44 (1118) 48 (1219) 58 (1473) 66 (1676) 70 (1778) 82 (2083)
L - in (mm) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762) 30 (762)
LAM Large Access H - in (mm) 22 (559) 22 (559) 22 (559) 30 (762) 34 (864) 34 (864) 44 (1118) 44 (1118) 44 (1118)
LFM
Lg. INTELLITRAC
®
Mix. Box w/V-Bank Filters (2")
W - in (mm) 30 (762) 36 (914) 44 (1118) 44 (1118) 48 (1219) 58 (1473) 66 (1676) 70 (1778) 58 (1473)
LIM
Lg. INTELLITRAC
®
Inlet Plenum w/V-Bank Filters (2")
L - in (mm) 42 (1067) 42 (1067) 42 (1067) 42 (1067) 42 (1067) 42 (1067) 42 (1067) 42 (1067) 42 (1067)
LMM Large Mixing Box with V-Bank Filters (2")
LRM Large Inlet Plenum with V-Bank Filters (2")
LPM Large Discharge Plenum
FCM FC Fan and Coil Combination (Horizontal Only) H - in (mm) 22 (559) 22 (559) 22 (559) 30 (762) 34 (864) 34 (864) 44 (1118) 44 (1118) 44 (1118)
HEM Horizontal Economizer W - in (mm) 30 (762) 36 (914) 44 (1118) 44 (1118) 48 (1219) 58 (1473) 66 (1676) 70 (1778) 82 (2083)
H - in (mm) 13-1/2 (343) 13-1/2 (343) 13-1/2 (343) 18 (457) 18 (457) 18 (457) 21 (533) 21 (533) 21 (533)
W - in (mm) 11-1/2 (292) 11-1/2 (292) 11-1/2 (292) 17 (432) 17 (432) 17 (432) 24 (610) 24 (610) 24 (610)
L - in (mm) 22 (559) 22 (559) 22 (559) 22 (559) 22 (559) 22 (559) 22 (559) 22 (559) 22 (559)
Electric Heat Draw Thru
Electric Heat Blow Thru
External Flat Filters (2")
UNIT CONFIGURATION (IN DIRECTION OF AIRFLOW)
EHD
EHB
EFM
Uppe r De ck - B
Low e r De ck - A
Notes:
1. All dimensions are +
1/4" (6mm). Metric
values are soft
conversions.
2. Section images are for
identification of unit
configuration only.
See individual section
submittal drawings at
www.enviro-tec.com
for details.
3. Certain configuration
rules apply; see cata-
log and selection
program for details.
4. All data subject to
change without
notice.
Fig. 1
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 3
Fig. 4
Fig. 4
Fig. 5
ENVIRO-TEC
ELECTRIC HEAT • MQL
7
STANDARD FEATURES
• G60 galvanized steel casing
• Flanged construction for direct unit
mounting, in blow thru configuration
• Listed for zero clearance installation
• Meets National Electrical Code requirements
• Ni-Chrome wire in ceramic insulators
• Stainless steel element terminals
and hardware
• Element support brackets on maximum
3 1/2" centers
• Solid cover with continuous full height hinge
• Overtemperature protection
• All internal wiring rated for 105°C minimum
• Airflow switch
• Incoming line power distribution block
• ETL Listed in compliance with UL/ANSI Standard 1995
• Single point power connection
• Heater factory mounted to unit with ETL listing as an
assembly
OPTIONAL FEATURES
• Main incoming power disconnect (non-fused) (fused)
• Fusing (main) (per stage)
• Magnetic contactors wired for disconnecting operation
• Solid state relay with 4-20 mA, thermistor 0-135 Ohm, 0-16 VDC, or 6-9 VDC control
• Fan control package with heater interlock contacts (required for single point power connection)
• De-rated elements (for longer life)
Blow Thru
(installed on unit discharge)
Side View Front View
Airflow
Draw Thru
(installed upstream of fan)
Side View
Airflow
VOLTAGE
115/1 208/1 230/1 277/1 208/3 230/3 460/3 575/3
4.81
4.35
3.61
HEATER AMP CALCULATION
AMPs per kW
8.70
1.00
2.78
2.51
1.26
1.Refer to MCA/MOP Calculator at www.enviro-tec.com for MCA and/or MOP calculations.
2. Non-Fused Door Interlock Disconnect Switch shall be sized according to MCA.
3. Fused Door Interlock Disconnect Switch and Main Fusing shall be sized according to MOP.
4. Heaters above 480v must utilize one time secondary limits only.
Plan View
ENVIRO-TEC
MQL • ELECTRIC HEAT
8
Notes:
1. Blow thru heaters can have a maximum of two stages.
2. VFD controllers cannot be supplied with blow thru heaters.
3. Specific kW ratings are available within the ranges shown. Refer to selection program.
4. Heaters above 480v must utilize one time secondary limits only.
Notes:
1. Draw thru heaters can have a maximum of four stages.
2. All heaters that have an AMP draw greater than 48 AMPs will have a minimum of two stages.
3. Specific kW ratings are available within the ranges shown. Refer to selection program.
4. Heaters above 480v must utilize one time secondary limits only.
Min Ma x Mi n Max Min Ma x Min Max Min Ma x Mi n Max Min Ma x Mi n Max Min Ma x
kW353545
AMPs 26.1 43.5 26.1 43.5 34.8 43.5
kW3103104106.016716920
AMPs 14.4 48.1 14.4 48.1 19.2 48.1 28.8 76.9 33.7 76.9 43.3 96.2
kW3113114116.018718922
AMPs 13.0 47.8 13.0 47.8 17.4 47.8 26.1 78.3 30.4 78.3 39.1 95.7
kW3133134136.022722926
AMPs 10.8 46.9 10.8 46.9 14.4 46.9 21.7 79.4 25.3 79.4 32.5 93.9
kW3133204264.026728934124614461646
AMPs 8.3 36.1 8.3 55.5 11.1 72.2 11.1 72.2 19.4 77.7 25.0 94.4 33.3 127.7 38.9 127.7 44.4 127.7
kW3133204264.026732934124914491649
AMPs 7.5 32.6 7.5 50.2 10.0 65.3 10.0 65.3 17.6 80.3 22.6 85.3 30.1 123.0 35.1 123.0 40.2 123.0
kW3133204264.026752964127614881696
AMPs 3.8 16.3 3.8 25.1 5.0 32.6 5.0 32.6 8.8 65.3 11.3 80.3 15.1 95.4 17.6 110.4 20.1 120.5
kW3133204264.026752964127614881696
AMPs 3.0 13.1 3.0 20.1 4.0 26.1 4.0 26.1 7.0 52.2 9.0 64.3 12.0 76.3 14.1 88.4 16.1 96.4
UNIT
VOLTAGE
AND PHA SE
DRAW- T HRU EL ECT RI C HEAT
Unit Size
020304060810121417
Single Phase
115
230
208
277
Three Phase
208
230
460
575
Min Ma x Mi n Max Min Ma x Min Max Min Ma x Mi n Max Min Ma x Mi n Max Min Ma x
kW353545
AMPs 26.1 43.5 26.1 43.5 34.8 43.5
kW3939496979
AMPs 14.4 43.3 14.4 43.3 19.2 43.3 28.8 43.3 33.7 43.3
kW3113114116.011711911
AMPs 13.0 47.8 13.0 47.8 17.4 47.8 26.1 47.8 30.4 47.8 39.1 47.8
kW3133134136.013713913
AMPs 10.8 46.9 10.8 46.9 14.4 46.9 21.7 46.9 25.3 46.9 32.5 46.9
kW3133164164.01671691612161416
AMPs 8.3 36.1 8.3 44.4 11.1 44.4 11.1 44.4 19.4 44.4 25.0 44.4 33.3 44.4 38.9 44.4
kW3133184184.018718918121814181618
AMPs 7.5 32.6 7.5 45.2 10.0 45.2 10.0 45.2 17.6 45.2 22.6 45.2 30.1 45.2 35.1 45.2 40.2 45.2
kW3133204264.026738938123814381638
AMPs 3.8 16.3 3.8 25.1 5.0 32.6 5.0 32.6 8.8 47.7 11.3 47.7 15.1 47.7 17.6 47.7 20.1 47.7
kW3133204264.026746946124614461646
AMPs 3.0 13.1 3.0 20.1 4.0 26.1 4.0 26.1 7.0 46.2 9.0 46.2 12.0 46.2 14.1 46.2 16.1 46.2
06
08
UNIT
VOLTAGE
AND PHA SE
Three Phase
208
230
460
575
BLOW - THRU ELECTRI C HEAT
Unit Size
1417101204
Single Phase
02
03
208
230
277
115
ENVIRO-TEC
COIL AND FILTER DATA • MQL
9
ENVIRO-TEC®offers hot water, chilled water, direct expansion (DX), and standard steam coils for specific application with all Model MQL blower coils. Coils tested in accordance with ARI 410, and strict on-site inspection before, during, and after installation guarantees the highest quality and performance available.
Standard Features
• ENVIRO-TEC® coils are designed, manufactured and tested by Johnson Controls
• 1/2" O.D. seamless copper tubes
• Aluminum fin construction with die-formed spacer collars for uniform spacing
• Mechanically expanded copper tubes leak tested to a minimum 450 PSIG air pressure under water
• Manual air vent plug on all water coils
• Copper ODM sweat connections
• 300 PSIG working pressure at 200°F
• Evaporator coils are factory sealed and charged with a minimum of 5 PSIG nitrogen or refrigerated dry air
• Refrigerant coils are provided with a fixed orifice dis­tributor. Thermal expansion valves are not included.
• Steam coils rated at maximum for 15 PSIG
• 0.016" tube wall thickness (0.025" on steam)
Optional Features
• Stainless steel coil casings
• Automatic air vents on water coils
• Elevated working pressure ratings
• Heat pump compatible cooling coils
• Double circuit DX coils (50-50 split)
• 0.025" tube wall thickness
Coil
Face Area Qty. Dimensions Face Area Qty. Dimensions Face Area
02 2.1 [0.20] 1 16x20x2 [406x508x51] 2.2 [0. 20] 2 16x20x2 [406x508x51] 4.4 [0.41]
03 2.9 [0.27] 1 16x25x2 [406x635x51] 2.8 [0. 26] 2 16x25x2 [406x635x51] 5.6 [0.52]
04 3.8 [0.35] 2 16x20x2 [406x508x51] 4.4 [0. 41] 2 20x25x2 [508x635x51] 6.9 [0.64]
06 5.6 [0.52] 2 20x25x2 [508x635x51] 6.9 [0. 64] 4 20x20x2 [508x508x51] 11.1 [1.03]
08 7.4 [0.69] 2 20x25x2 [508x635x51] 6.9 [0. 64]
2 2
16x20x2 [406x508x51] 20x25x2 [508x635x51]
11.4 [1. 06]
10 9.7 [0.90]
1 2
16x25x2 [406x635x51] 20x25x2 [508x635x51]
9.7 [0. 90]
2 4
16x20x2 [406x508x51] 20x20x2 [508x508x51]
15.6 [1. 45]
12 12.6 [1.17] 4 20x25x2 [508x635x51] 13.9 [1. 29] 6 20x25x2 [508x635x51] 20.8 [1.93]
14 14.3 [1.33] 8 16x20x2 [406x508x51] 17.8 [1. 65]
3 6
20x25x2 [508x635x51] 20x20x2 [508x508x51]
27.1 [2. 52]
17 17.0 [1.58] 6 20x25x2 [508x635x51] 20.8 [1. 93] 12 20x20x2 [508x508x51] 33.3 [3.09]
COIL AND FILTER DATA
Unit Sizes
V-Bank Filters
Flat Filters
NOTES:
1. Standard filters are 2" throwaway; optional filters are 2" pleated.
2. Filter sizes are nominal and standard size, measured in inches [millimeters].
3. Coil and filter face areas are measured in square feet [square meters].
4. Cooling and heating coils have same face area.
5. For coil connection sizes, refer to the ENVIRO-TEC
®
Coil Selection Program.
ENVIRO-TEC