Entryvue VD-950 Instruction Manual

Door Station A Door Station B Door Station C Door Station F Door Station G
The design and specications of this manual can be changed without notication to the user. All copyrights and interpretation rights are reserved to Evervue.
1
2
ON
DPS
Basic instructions:
*One Door station *One Monitor *DPS Box (Power distributor Box) *Power Supply (PS-50 or PS-55)
2. Recommended wires are:
*14 gauge 2 conductor stranded wire. *CAT5 (MUST use a pair of wire for each conductor) Strip the ends of the wires about 1/3”. If using stranded wires or CAT5, solder the ends to ensure a good connection. Do Not use wire nuts to connect wires(wire nuts are for power and solids wires).
3. If multiple door stations and monitors are used, you can con nect them in series (daisy chain) or in parallel.
4. Connect the wire to the BUS connection on the Door Station ( 2 connections on the left ). Then connect the other end of that same wire to the left connectionon the DPS box.
4.1 Connect the wire to the right side of the DPS Box. Then connect the other end of that same wire to the green plug and then to the back of the monitor. Make sure that these wires do not twist too much, and that they are well isolated from each other.
5. Door Strike/Magnetic lock
5.1 Door Lock controlled by Dry Contact: If you have a large system, it is not recommended to have the Door Station providing the power for the lock, so use a separate power supply for the door lock.
The unlock setting on monitor: 8010 - lock mode to 0 - Normally open 8011 - lock mode to 1 - Normally closed
*Use Exit Bottom with magnetic lock only.
good
wrong
well twisted and soldered
Connect one lock
lock lock 1
lock 2
Remove jumper
Connect two locks
Remove jumper
*Exit Button ( Magnetic lock only )
*Exit Button ( Magnetic lock only )
Page 01
4.2. Connect the Red Wire of the DPS Box to the Positive (24V) of the power supply, usually the V+ or the Red connection. The black wire should connect to the V- or the black connection of the power supply.
4.3. Plug in the power supply. Connect the terminal L and N to 110 ­240V input. This can be hardwired, or you can connect a cable w ith a plug. If you have a PS-55, make sure that the voltage switch in the unit is set to 110V or 220V before turning ON (depending the country you live).
5.2 Door Lock controlled with Internal Power - Door strike:
Recommended only for 1 Door Station + 1 Monitor
-The door lock is limited to 12V, 250mA
-The Unlock Setting of monitor must be set to 0 (by default).
6. Ensure to set the Dip Switches of the Door Stations and Monitors correctly. Refer to the next page.
7. Unlock Setting (set in monitor)
-You must connect the system correctly before programming the unlock setting.
-It will be saved automatically, so you only need to set in one monitor.
1. Press the “EntryVue” logo located on the bottom left of the screen.
2. Press the screen for 3 seconds,then select “Installer’s Menu .”
3. Then enter one of the following codes: 8021# : 1 second 8022# : 2 seconds 8023# : 3 seconds 8024# : 4 seconds 8025# : 5 seconds 8026# : 6 seconds 8027# : 7 seconds 8028# : 8 seconds 8029# : 9 seconds
8.Innercall Feature;
There are 2 ways to set up the intercom function, and you need to decide which one you want during the set up.
1. You can call a specic monitor. This is the standard defau lt.
2. You can innercall up to 4 monitors. In this case, you need t o set all 4 monitors with the same dip switches and one of them needs to be set as “master”. The other 3 must be set as “slave” in the “Installer’ s Menu” (Press the “EntryVue” logo located on the bottom left of the sc reen).
Jumper position in 1-2
Lock
9. Showing video on multiple monitors:
You can have up to 3 or 4 monitors (depending on the distance) showing video when the door bell is pressed. Default setting is to one monitor showing video. On the monitor that you want to show video, press the “EntryVue” Logo, then press the screen for 3 seconds, and then enter the code 8006#.
10. Maximum distance:
Wire used
CAT5 or CAT6
18/2 speake wire (stranded,not shielded)
14/2 speake wire (stranded,not shielded)
Maximum distance between door station and monitor
Use 1 pair for each conductor. Solder the ends of the pair together
Solder connections together. Set voltage between 25-27 volt (can be adjusted on the power supply)
300 feet (100 meters)
Comment
300 feet (100 meters)
500 feet (150 meters)
Page 02